ChipFind - документация

Электронный компонент: HLMP-EL30-LP000

Скачать:  PDF   ZIP

Document Outline

T-1
3
/
4
(5 mm) Precision Optical
Performance AlInGaP LED
Lamps
Data Sheet
Features
Well Defined Spatial
Radiation Patterns
Viewing Angles: 6
, 15
,
23
, 30
High Luminous Output
Colors:
590 nm Amber
605 nm Orange
615 nm Reddish-Orange
626 nm Red
High Operating
Temperature:
T
J LED
= +130
C
Superior Resistance to
Moisture
Package Options:
With or Without Lead Stand-
Offs
Benefits
Viewing Angles Match
Traffic Management Sign
Requirements
Colors Meet Automotive and
Pedestrian Signal
Specifications
Superior Performance in
Outdoor Environments
Suitable for Autoinsertion
onto PC Boards
Applications
Traffic Management:
Traffic Signals
Pedestrian Signals
Work Zone Warning Lights
Variable Message Signs
Commercial Outdoor
Advertising:
Signs
Marquees
Automotive:
Exterior and Interior Lights
Description
These Precision Optical Perform-
ance AlInGaP LEDs provide
superior light output for excellent
readability in sunlight and are
extremely reliable. AlInGaP LED
technology provides extremely
stable light output over long
periods of time. Precision Optical
Performance lamps utilize the
aluminum indium gallium phos-
phide (AlInGaP) technology.
These LED lamps are untinted,
nondiffused, T-1
3
/
4
packages
incorporating second generation
optics producing well defined
spatial radiation patterns at
specific viewing cone angles.
SunPower Series
HLMP-ELxx
HLMP-EJxx
HLMP-EHxx
HLMP-EGxx
These lamps are made with an
advanced optical grade epoxy,
offering superior high tempera-
ture and high moisture resistance
performance in outdoor signal
and sign applications. The high
maximum LED junction tempera-
ture limit of +130
C enables high
temperature operation in bright
sunlight conditions. The package
epoxy contains both uv-a and
uv-b inhibitors to reduce the
effects of long term exposure to
direct sunlight.
These lamps are available in two
package options to give the
designer flexibility with device
mounting.
2
2
Device Selection Guide
Typical
Viewing
Color and
Luminous
Angle
Dominant
Lamps Without Standoffs
Lamps With Standoffs
Intensity Iv (mcd)
[1,2]
2
1
/
2
Wavelength
on Leads
on Leads
@ 20 mA
(Deg.)
[4]
(nm), Typ.
[3]
(Outline Drawing A)
(Outline Drawing B)
Min.
Max.
HLMP-EL08-VY000
HLMP-EL10-VY000
3600
13800
HLMP-EL08-VYK00*
3600
13800
HLMP-EL08-VXK00*
3600
10700
HLMP-EL08-VX400**
3600
10700
HLMP-EL08-VX000
3600
10700
HLMP-EL08-WZ000
HLMP-EL10-WZ000
4700
18400
Amber 590
HLMP-EL08-XZ400**
6200
18400
HLMP-EL08-XZ000
6200
18400
HLMP-EL08-XZK00*
6200
18400
HLMP-EL08-XY000
6200
13800
HLMP-EL08-XYK00*
6200
13800
HLMP-EL08-X1K00*
6200
24100
HLMP-EL08-X1000
HLMP-EL10-X1000
6200
24100
6
[5]
HLMP-EJ08-WZ000
HLMP-EJ10-WZ000
4700
18400
Orange 605
HLMP-EJ08-X1000
HLMP-EJ10-X1000
6200
24100
HLMP-EJ08-Y2000
HLMP-EJ10-Y2000
8000
31000
HLMP-EH08-UX000
HLMP-EH10-UX000
2750
10700
HLMP-EH08-VY000
HLMP-EH10-VY000
3600
13800
Red-Orange 615
HLMP-EH08-WZ000
HLMP-EH10-WZ000
4700
18400
HLMP-EH08-X1000
HLMP-EH10-X1000
6200
24100
HLMP-EH08-Y2000
HLMP-EH10-Y2000
8000
31000
HLMP-EG08-VW000
3600
8300
HLMP-EG08-VY000
HLMP-EG10-VY000
3600
13800
HLMP-EG08-WZ000
HLMP-EG10-WZ000
4700
18400
Red 626
HLMP-EG08-X1000
HLMP-EG10-X1000
6200
24100
HLMP-EG08-YZ000
8000
18400
HLMP-EG08-Y1000
8000
24100
HLMP-EG08-Y2000
HLMP-EG10-Y2000
8000
31000
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2.
The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
1/2
is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
3
Typical
Viewing
Color and
Luminous
Angle
Dominant
Lamps Without Standoffs
Lamps With Standoffs
Intensity Iv (mcd)
[1,2]
2
1
/
2
Wavelength
on Leads
on Leads
@ 20 mA
(Deg.)
[4]
(nm), Typ.
[3]
(Outline Drawing A)
(Outline Drawing B)
Min.
Max.
HLMP-EL15-PS000
HLMP-EL17-PS000
765
2900
HLMP-EL15-QR000
1000
2200
HLMP-EL15-QRK00*
1000
2200
HLMP-EL15-QS000
1000
2900
HLMP-EL15-QS400**
1000
2900
HLMP-EL15-QSK00*
1000
2900
HLMP-EL15-QT000
HLMP-EL17-QT000
1000
3700
HLMP-EL15-QTK00*
1000
3700
HLMP-EL15-RU000
HLMP-EL17-RU000
1300
4800
HLMP-EL17-SV000
1650
6300
Amber 590
HLMP-EL15-TW000
HLMP-EL17-TW000
2170
8300
HLMP-EL15-TWK00*
2170
8300
HLMP-EL15-TUK00*
2170
4800
15
HLMP-EL15-TV400**
2170
6300
HLMP-EL15-UX000
HLMP-EL17-UX000
2750
10700
HLMP-EL15-VY000
HLMP-EL17-VY000
3600
13800
HLMP-EL15-VYK00*
3600
13800
HLMP-EL15-VX000
3600
10700
HLMP-EL15-VXK00*
3600
10700
HLMP-EL15-VX400**
3600
10700
HLMP-EL15-VW000*
3600
8300
HLMP-EL15-VWK00*
3600
8300
HLMP-EJ15-PS000
765
2900
Orange 605
HLMP-EJ15-RU000
HLMP-EJ17-RU000
1300
4800
HLMP-EJ15-SV000
HLMP-EJ17-SV000
1650
6300
HLMP-EH15-QT000
HLMP-EH17-QT000
1000
3700
Red-Orange 615
HLMP-EH15-RU000
HLMP-EH17-RU000
1300
4800
HLMP-EH15-TW000
HLMP-EH17-TW000
2170
8300
HLMP-EH15-UX000
HLMP-EH17-UX000
2750
10700
Device Selection Guide (Continued)
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2.
The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
1/2
is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
4
4
Device Selection Guide (Continued)
Typical
Viewing
Color and
Luminous
Angle
Dominant
Lamps Without Standoffs
Lamps With Standoffs
Intensity Iv (mcd)
[1,2]
2
1
/
2
Wavelength
on Leadson Leads
@ 20 mA
(Deg.)
[4]
(nm), Typ.
[3]
(Outline Drawing A)
(Outline Drawing B)
Min.
Max.
HLMP-EG15-PS000
765
2900
HLMP-EG15-QT000
HLMP-EG17-QT000
1000
3700
15
Red 626
HLMP-EG15-RU000
HLMP-EG17-RU000
1300
4800
HLMP-EG15-UX000
HLMP-EG17-UX000
2750
10700
HLMP-EG15-TW000
HLMP-EG17-TW000
2170
8300
HLMP-EL24-MQ000
450
1730
HLMP-EL24-NR000
HLMP-EL26-NR000
590
2200
HLMP-EL24-PS000
HLMP-EL26-PS000
765
2900
HLMP-EL24-PSK00*
765
2900
HLMP-EL24-PR400**
765
2200
HLMP-EL24-PQK00*
765
1730
HLMP-EL24-QR000
1000
2200
HLMP-EL24-QRK00*
1000
2200
HLMP-EL24-QS000
1000
2900
HLMP-EL24-QSK00*
1000
2900
HLMP-EL24-QS400**
1000
2900
23
Amber 590
HLMP-EL24-QT000
HLMP-EL26-QT000
1000
3700
HLMP-EL24-QTK00*
1000
3700
HLMP-EL24-RU000
HLMP-EL26-RU000
1300
4800
HLMP-EL24-RUK00*
1300
4800
HLMP-EL26-SV000
1650
6300
HLMP-EL24-ST000
1650
3700
HLMP-EL24-STK00*
1650
3700
HLMP-EL24-SU000
1650
4800
HLMP-EL24-SUK00*
1650
4800
HLMP-EL24-SU400**
1650
4800
HLMP-EL24-SV000
1650
6300
HLMP-EL24-SVK00*
1650
6300
HLMP-EL24-TW000
HLMP-EL26-TW000
2170
8300
HLMP-EL24-TWK00*
2170
8300
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2.
The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
1/2
is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.
5
Typical
Viewing
Color and
Luminous
Angle
Dominant
Lamps Without Standoffs
Lamps With Standoffs
Intensity Iv (mcd)
[1,2]
2
1
/
2
Wavelength
on Leads
on Leads
@ 20 mA
(Deg.)
[4]
(nm), Typ.
[3]
(Outline Drawing A)
(Outline Drawing B)
Min.
Max.
Orange 605
HLMP-EJ24-QT000
HLMP-EJ26-QT000
1000
3700
HLMP-EJ24-RU000
HLMP-EJ26-RU000
1300
4800
HLMP-EH26-PS000
765
2900
Red-Orange 615
HLMP-EH24-QT000
HLMP-EH26-QT000
1000
3700
23
HLMP-EH24-RU000
HLMP-EH26-RU000
1300
4800
HLMP-EH24-SV000
HLMP-EH26-SV000
1650
6300
HLMP-EG24-PS000
HLMP-EG26-PS000
765
2900
Red 626
HLMP-EG24-QT000
HLMP-EG26-QT000
1000
3700
HLMP-EG24-RU000
HLMP-EG26-RU000
1300
4800
HLMP-EL30-MQ000
HLMP-EL32-MQ000
450
1730
HLMP-EL30-NR000
HLMP-EL32-NR000
590
2200
HLMP-EL30-PQ000
765
1730
HLMP-EL30-PQK00*
765
1730
HLMP-EL30-PR000
765
2200
HLMP-EL30-PR400**
765
2200
HLMP-EL30-PRK00*
765
2200
HLMP-EL30-PS000
HLMP-EL32-PS000
765
2900
30
Amber 590
HLMP-EL30-PSK00*
765
2900
HLMP-EL30-QT000
HLMP-EL32-QT000
1000
3700
HLMP-EL30-QTK00*
1000
3700
HLMP-EL30-QS000
1000
2900
HLMP-EL30-QS400**
1000
2900
HLMP-EL30-QRK00*
1000
2200
HLMP-EL30-SU000
1650
4800
HLMP-EL30-SUK00*
1650
4800
HLMP-EL30-SU400**
1650
4800
HLMP-EL30-ST000
1650
3700
Device Selection Guide (Continued)
Notes:
1. The luminous intensity is measured on the mechanical axis of the lamp package.
2.
The optical axis is closely aligned with the package mechanical axis.
3. The dominant wavelength,
d
, is derived from the CIE Chromaticity Diagram and represents the color of the lamp.
4.
1/2
is the off-axis angle where the luminous intensity is one half the on-axis intensity.
5. The intensity of narrow viewing angle lamps is measured at the intensity peak.
Part numbers in bold are recommended for new designs.
*HLMP-xLxx-xxK00 are selected to amber color bins 2 and 4 only.
**HLMP-xLxx-xx400 are selected to amber color bin 4 only.