ChipFind - документация

Электронный компонент: D13007

Скачать:  PDF   ZIP
KST-H035-000
1
STD13007F
NPN Silicon Power Transistor
Features
High speed switching
High Collector Voltage : V
CBO
= 700V
Suitable for Switching Regulator and Motor Control
Ordering
Information
Type NO. Marking Package Code
STD13007F STD13007 TO-220F

Outline Dimensions unit :
mm
S
S
e
e
m
m
i
i
c
c
o
o
n
n
d
d
u
u
c
c
t
t
o
o
r
r
PIN Connections
1. Base
2. Collector
3. Emitter
KST-H035-000
2
STD13007F

Absolute maximum ratings
(Ta=25
C)
Characteristic Symbol
Rating
Unit
Collector-Base voltage
V
CBO
700 V
Collector-Emitter voltage
V
CEO
400 V
Emitter-base voltage
V
EBO
9 V
Collector current (DC)
I
C
8 A
Collector current (Pulse)
I
CM
16 A
Base current (DC)
I
B
4 A
Collector Power dissipation (Tc=25)
P
C
40 W
Junction temperature
T
j
150
C
Storage temperature
T
stg
-55~150 C
Electrical Characteristics
(Ta=25
C)
Characteristic Symbol
Test
Condition
Min.
Typ.
Max.
Unit
Collector-Emitter sustaining voltage
BV
CEO(sus)
I
C
=10mA, I
B
=0 400
-
-
V
Emitter cut-off current
I
EBO
V
EB
=9V, I
C
=0 -
-
1
mA
I
C
=2A, V
CE
=5V 8
-
60
DC Current gain
h
FE
*
I
C
=5A, V
CE
=5V 5
-
30
I
C
=2A, I
B
=0.4A -
-
1
I
C
=5A, I
B
=1A -
-
2
Collector-Emitter saturation voltage
V
CE(sat)
*
I
C
=8A, I
B
=2A -
-
3
V
I
C
=2A, I
B
=0.4A -
-
1.2
Base-Emitter saturation voltage
V
BE(sat)
*
I
C
=5A, I
B
=1A -
-
1.6
V
Transition frequency
f
T
V
CE
=10V, I
C
=0.5A, f=1MHz
-
14
-
MHz
Output capacitance
C
ob
V
CB
=10V, I
E
=0, f=0.1MHz
-
80
-
Turn on Time
t
on
-
-
1.6
Storage Time
t
stg
-
-
3
Fall Time
t
f
V
CC
=125V, I
C
=5A
I
B1
=-I
B2
=1A
- - 0.7
* Pulse test: PW300 , Duty cycle2%.
KST-H035-000
3
STD13007F
Electrical Characteristic Curves
Fig. 1 P
C
- T
C
Fig. 2 V
BE(sat)
, V
CE(sat)
- I
C
Fig. 3 h
FE-
I
C
Fig. 4 t
f
, t
stg
- IC
Fig. 5 td , tr - IC
Fig. 6 Cob - V
CB
KST-H035-000
4
STD13007F
Fig. 7 Safe Operating Area
KST-H035-000
5
STD13007F
These AUK products are intended for usage in general electronic equipments(Office and
communication equipment, measuring equipment, domestic electrification, etc.).
Please make sure that you consult with us before you use these AUK products in equipm-
ents which require high quality and/or reliability, and in equipments which could have
major impact to the welfare of human life(atomic energy control, airplane, spaceship, traffic
signal, combustion central, all types of safety device, etc.).
AUK cannot accept liability to any damage which may occur in case these AUK products
were used in the mentioned equipments without prior consurtation with AUK.