ChipFind - документация

Электронный компонент: RP130440-5-24

Скачать:  PDF   ZIP
Specifications are subject to change without notice
(30.06.1999)
1
Solid State Relays
PCB, 1-Phase ZS
Types RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24
AC Solid State Relay for PCB mounting
Zero switching
Rated operational current: 3 or 5 AACrms
Non-repetitive voltage: Up to 850 V
p
Rated operational voltage: 240 V or 440 VACrms
5 VDC logic compatible input
12 and 24 VDC inputs for interfacing PLCs and
other controls
Insulation: OPTO (input-output) 4000 VACrms
Product Description
Ordering Key
Solid State Relay (PCB)
Mounting type
Switching mode
Rated operational voltage
Rated operational current
Control voltage
Rated operational
Control voltage
Rated operational current
voltage
3 AACrms
5 AACrms
5 VDC
RP 130 240-3-05
RP 130 240-5-05
12 VDC
RP 130 240-3-12
RP 130 240-5-12
24 VDC
RP 130 240-3-24
RP 130 240-5-24
5 VDC
RP 130 440-3-05
RP 130 440-5-05
12 VDC
RP 130 440-3-12
RP 130 440-5-12
24 VDC
RP 130 440-3-24
RP 130 440-5-24
Switching mode
Rated operational voltage
Rated operational current
Control voltage
130: Zero switching
240: 230 VACrms
3: 3 AACrms
05:
5 VDC
440: 400 VACrms
5: 5 AACrms
12:
12 VDC
24:
24 VDC
Type Selection
Selection Guide
230 VACrms
400 VACrms
RP 130 240-5-12
The RP Solid State Relays
from Carlo Gavazzi feature a
very reliable design due to use
of optotechnology together
with high performance power
semiconductors.
Either 3 or 5 A relays are avail-
able for AC mains up to 400
VACrms.
The zero switching version
will work for resistive and in-
ductive loads.
With snubberless triacs as
output devices, dV/dt limiting
RC-networks are no longer
required when switching in-
ductive loads.
2
Specifications are subject to change without notice
(30.06.1999)
RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24
RP 130 240-.-..
RP 130 440-.-..
Operational voltage range
24 to 280 VACrms
48 to 480 VACrms
Non-rep. peak voltage
650 V
p
850 V
p
Zero voltage turn-on
30 V
50 V
Operational frequency range
45 to 65 Hz
45 to 65 Hz
Power factor
0.5 @ 230 VACrms
0.5 @ 400 VACrms
Approvals
UL, CSA, VDE
UL, CSA, VDE
CE-marking
Yes
Yes
General Specifications
RP 130 .40-.-05
RP 130 .40-.-12
RP 130 .40-.-24
Control voltage range
4 to 8 VDC
8 to 16 VDC
16 to 32 VDC
Control voltage
5 VDC
12 VDC
24 VDC
Pick-up voltage
4 VDC
8 VDC
16 VDC
Drop-out voltage
1 VDC
1 VDC
1 VDC
Input current @ rated voltage
10 mADC
10 mADC
10 mADC
Reverse voltage
6 VDC
6 VDC
6 VDC
Response time pick-up
1/2 cycle
1/2 cycle
1/2 cycle
Response time drop-out
1/2 cycle
1/2 cycle
1/2 cycle
Input Specifications
RP 13. .40-3-0
RP 13. .40-5-0
Operating temperature
-20 to +70C (-4 to +158F)
-20 to +70C (-4 to +158F)
Storage temperature
-40 to +100C (-40 to +212F)
-40 to +100C (-40 to +212F)
Junction temperature
125C (
257F)
125C (
257F)
R
th
junction to case
20.5 K/W
15.6 K/W
R
th
junction to ambient
33 K/W
21 K/W
Thermal Specifications
Output Specifications
RP 130 .40-3-0
RP 130 .40-5-0
Rated operational current AC 1
3 Arms
5 Arms
AC 3 2.5 Arms
3 Arms
Minimum operational current
20 mArms
20 mArms
Rep. overload current t=1 s
6 A
p
12 A
p
Non-rep. surge current t=20 ms 60 A
p
90 A
p
Off-state leakage current
@ rated voltage and frequency
1 mArms
1 mArms
I
2
t for fusing t=1-10 ms
18 A
2
s
40 A
2
s
Critical dI/dt
20 A/ms
20 A/ms
On-state voltage drop
@ rated current
1.2 Vrms
1.2 Vrms
Critical dV/dt commutating
100 V/s
100 V/s
Critical dV/dt off-state
100 V/s
100 V/s
Specifications are subject to change without notice
(30.06.1999)
3
Insulation Input - Output
Rated insulation voltage
4000 VACrms
Insulation resistance
10
10
Insulation capacitance
8 pF
Reference voltage
according to VDE 0110 B
Insulation group C
500 VACrms, 600 VDC
Derating Curve
Wiring Diagram
Mains input/
load output
Control
input
Load output/
mains input
Functional Diagram
Dimensions
Housing Specifications
Applications
These relays can be used to
switch heaters, motors, lights,
valves or solenoids.
When used at full load current,
the relays must be placed
vertically. If more than one
relay is mounted, please
allow a minimum distance of
20 mm in between for suffi-
cient air cooling.
Accessories
Varistors
Fuses
For further information refer to "General Accessories".
4
6
5
3
2
1
0
0 10
20 30
40 50
60 70
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ambient temp. [C]
Load current [A AC rms]
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight
Approx. 10 g
Housing material
Noryl GFN 1, black
Terminals
Copper, tin-plated
Potting compound
Flame-retardant polyurethane
Line/load
Control
input
+3
-4
2
1
IC
* = 0.2 mm
** = 0.5 mm
43 *
10.5 **
6 **
25.4 *
1 2 +3 4
4 x 1
11M
9M
4M
3M
1M
M = 1/10" = 2.54 mm
RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24