ChipFind - документация

Электронный компонент: S1430ROS915

Скачать:  PDF   ZIP
Specifications are subject to change without notice (25.06.99)
1
Supply to photoelectric switch
Emitter (cont.)
Supply voltage (open loop)
7 V square wave
Current
300 mA short-circuit
protected
Output resistance
10
Receiver
Rx1: Pin 4
Rx2: Pin 7
Rx3: Pin 8
Shield: Pin 5 (common)
Supply voltage (open loop)
5 VDC
Short-circuit current
10 mA
Input resistance
470
Sensitivity
2 ranges,
(% of S
n
)
DIP-switch selectable
- low sensitivity (25%)
- high sensitivity (100%)
Sensitivity adjustment
with 270:
Turn knob on CH 1, 2, 3
Note:
Maximum range indicated
on photoelectric switch
data sheet in high sensi-
tivity range only
Operation within low sen-
sitivity range, increases
ambient light and cross-
talk immunity
Rated operational voltage (U
B
)
pins 2 & 10
DC
13.5 to 33 VDC
AC
13.5 to 33 VAC, 45 to 65 Hz
Rated operational power
AC supply
5 VA
DC supply
5 W
Power ON delay (t
v
)
< 300 ms
Output
Contact Rating (AgCdO)
Resistive loads
AC 1
1.5 A/100 VAC
DC 1
1.5 A/30 VDC
Small induc. loads
AC 15 1.5 A/100 VAC
DC 13 1.5 A/30 VDC
Mechanical life (typical)
20 x10
6
operations at
18000 imp/H
Electrical life (typical)
300000 operating at
220 VAC - 2A resistive load
Output function
Relay Make function
Protection, outputs
Reverse polarity, short-circuit,
transients
Supply to photoelectric switch
Emitter
Tx1: Pin 1
Tx2: Pin 9
Tx3: Pin 6
Shield: Pin 11 (common)
Photoelectrics
Amplifier, -Processor Controlled
Type S1430 ROS, 3 Inputs/3 Double Relay Outputs
Product Description
Ordering Key
Type
Special function
Output type
Power supply
-Processor controlled ampli-
fier for 3 sets of photoelec-
tric sensors, type MOFTR,
MKFTR, MIFTR or MHFTR.
Utilising an 11-pin circular
plug for easy connection.
Relay outputs (NO) w. 2
relays in series connection.
Self-diagnostics for system
test. Protected against
reverse wiring or cross talk
from adjecent photoelectrics.
Multi-voltage power supply.
Sensitivity is individually
adjustable for each set of
photoelectrics.
-Processor controlled
Amplifier unit for 3 sets of photoelectrics
3 independent outputs with 2 x Relay SPDT connected
in series, Make switching funktion
Self-diagnostic functions
Alignment failure indication
Multivoltage 15 to 30 VAC/DC
Modulated and synchronized light
Adjustable sensitivity for each channel
LED indications: supply, outputs, signal quality
11-pin plug-in housing
For 115 or 230 VAC use power supplys from SS120 series
Positive safety, NF P25-362 Standard
Type Selection
Plug type
Ordering no.
Supply: 15 - 30 VAC/DC
Circular, 11 pins
S 1430 ROS 915
Specifications
S14 30 ROS 915
2
Specifications are subject to change without notice (25.06.99)
Object present
Yes
No
No
Dirt on lenses,
misaligned or
--
No
Yes
1)
sensitivity too low
Output LED yellow
OFF
ON
ON
Level LED red
OFF
OFF
Output OFF
ON
ON
Operating frequency (f)
Light/dark ratio 1:1
12.5 Hz
Response time
OFF-ON (t
ON
)
30 ms
ON-OFF (t
OFF
)
30 ms
Indication
Supply ON
LED, green
Output ON
LED, yellow
Signal quality
LED, red
Environment
Overvoltage category
III (IEC 60664)
Degree of protection
IP 20 (IEC 60529, 60947-1)
Pollution degree
3 (IEC 60664/60664A,
60947-1)
Temperature
Operating
-20 to +50C (-4 to +122F)
Storage
-50 to +85C (-58 to 185F)
Weight
150 g
Approvals
CSA
CE-marking
Yes
S 1430 ROS
Specifications (cont.)
Truth Table
Make switching
ON
or
flashing
1)
Under normal operating conditions, the red level indication
LED has to be OFF. The level indication LED will turn on
shortly each time an object enters or exits the sensing
zone, even if the photoelectric switch is correctly installed
and adjusted.
Operation Diagram
Power supply
Object present
Signal quality
!
Procedure for Test Functions (Dip-switch Selection)
Transmitter test
(switch 1 in the up position)
When switch 1 is placed in
the up position all yellow and
red LED's on the front of the
unit will flash simultaneously.
Once the test is completed
(approx. 3 scans) and a
wiring fault is detected, such
as reverse polarity or short-
circuit, the transmitter that
has the fault condition will
be indicated by the red LED
being continuously ON. If a
fault condition is not existing
then only the yellow LED will
be ON. If a fault exists, cor-
rect the fault condition and
then repeat the test, this will
ensure proper wiring has
been done. Always
reset
switch 1 for normal opera-
tion of system when testing
completed.
Receiver test
(switch 2 in the up position)
When switch 2 is placed in
the up position all yellow and
red LED's on the front of the
unit will flash simultaneously.
Once the test is completed
(approx.
3 scans) and a
wiring fault is detected, such
as reverse polarity or short-
circuit, the receiver that has
the fault condition will be
indicated by the red LED
being continuously ON. If a
fault condition is not existing
then only the yellow LED will
be ON. If a fault exists, cor-
rect the fault condition and
then repeat the test, this will
ensure proper wiring has
been done. Always
reset
switch 2 for normal opera-
tion of system when testing
completed.
Function test
(switch 1 and 2 in the up position)
When switch 1 and 2 are
both placed in the up positi-
on (simultaneously) the yel-
low and red LED's on the
front of the housing will
begin to flash simultane-
ously and then the LED's
LED Indication
Yellow LED ON
Red LED OFF
Yellow LED ON
Red LED ON
Yellow LED OFF
Red LED ON
Make switching
System Test OK
}
Tx's and Rx's mismatched,
e.g. Rx3 seeing Tx1
}
}
Alignment error or beam
obstructed by object
!
!
!
Signal strength
Time
will cycle from channel 1 to
channel 2 and then to chan-
nel 3. Once the complete
system scan is done the
indication of the system
condition will be displayed
(see below). System test will
continue until switch 1 and 2
are reset.
Specifications are subject to change without notice (25.06.99)
3
DIP-switch (located behind cover):
1: Test button, transmitters are transmitting,
no short, wired correctly
2: Test button, receivers are receiving, no short,
wired correctly
1+2together: System test (transmitter and receiver)
S 1430 ROS
Dimensions
Wiring Diagrams
Accessories
- 11 pole circular socket
S111, S111A, S411, ZPD11
- Socket cover for S111
BB1
- Socket cover for S411
BB4
- Holding down spring
HF
- Mounting rack
SM13
- Front panel mounting bezel
FRS2
- Connection cable (2 plugs)
2 x 6/6 modular plugs
2 x 6/6 mod. 2.0 m
- Power supplies for 115/230 VAC SS120-series
- DIN-rail interface
6IODC
Delivery Contents
Output connection cable
1 m, 6 wires one plug
Output connection cable
0.2 m, 6 wires two plugs
Amplifier
S 1430 ROS 915
DIN-rail interface
6IODC
Screw driver
Packaging:
Cardboard box
A B C D E F
TEST
Output
Wire colour
coding
A: white
B:
Output 1 (max. 30 VDC, 100 VAC, 1.5A)
black
C: red
D:
Output 2 (max. 30 VDC, 100 VAC, 1.5A)
green
E: yellow
F:
Output 3 (max. 30 VDC, 100 VAC, 1.5A)
blue
ON sockets
1: Transmitter 1
2: Supply (+ VDC)
3: No connection
4: Receiver 1
5: GND (Receivers)
6: Transmitter 3
7: Receiver 2
8: Receiver 3
9: Transmitter 2
10: Supply (- VDC)
11: GND (Transmitters)
Power Supply
8
9
10
11
7
6
5
4
3
1
2
Rx 1
Rx 2
Rx 1
Rx 3
Tx 1
Tx 2
Rx 1
Tx 3
35
80
84
75
4
5
1 2
SW
Transmitter test.
Yellow ON: OK
Red ON: Error
Normal operation
sw 1:
Receiver test.
Yellow ON: OK
Red ON: Error
Normal operation
sw 2:
System test.
Yellow ON: OK
Red ON: Error
Both ON: Crosstalk
sw 1+2:
Normal operation
6IODC
DIN-rail interface
(DIN EN 50 035, EN 50 022)
output from plug to screw
terminnals
Interface
Test pins for contact verification is placed under
Front cover.
}
}
}