ChipFind - документация

Электронный компонент: CVT-2240

Скачать:  PDF   ZIP
Converts encoded badge information from Wiegand readers
to an ASCII string.
Encoded badge information is transmitted as an ASCII string.
The Reader's LED is activated by receiving a command string.
A command sequence also controls an on-board relay.
When connected to any Wiegand output reader, the encoded badge information is output as
a formatted ASCII string. The output of the CVT-2240 can then be captured by a
communications program running on a PC or printed directly on a serial printer. In
addition, commands can be sent to the CVT-2240 to control the reader's LED and activate
an auxiliary relay located on the Converter's circuit board.
Verifying encoded badge information.
Creating a database of existing badges.
Entering badge information into a program.
Testing badge or reader integrity.
Remote Control of Door strikes, MagLocks, Turnstiles, and Gate arms.
Features
Description
Applications
CVT-2240
RS-232
Any Wiegand output reader
CVT- 2240
Wiegand -> ASCII Converter
CYPRESS
INDUSTRY LEADERS DEPEND ON US ...FOR SOLUTIONS
Cypress Computer Systems, Inc. 1778 Imlay City Rd. Lapeer, MI 48446-3206
TX(810)245-2300 FX(810)245-2332 www.cypresscom.com
2.9
2.5
3.1
side view
Common
+8 to +24 Vdc @ 150 ma
Ground
+5 Vdc @ 100 ma
Data 0
Data 1
LED
Normally Open
Normally Closed
Ground
Wiegand to
ASCII
Converter
CVT-2240
Door Strike Relay
125 Vac @ 1 Amp
Open Collector (30 Vdc Max)
Open Collector or 5 Vdc Pulses
DB-9
Female
1.1
DB-9 Female
1...DCD unused
2...RX Data from Terminal/Printer
3...TX Data from CVT-2240
4...DTR unused
5...Ground
6...DSR unused
7...RTS
8...CTS
9...RI unused
5
4
3
2
1
9
8
7
6
Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446
TX(810)245-2300 FX(810)245-2332 www.cypresscom.com
This Device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference,
(2) this device must accept any interference received,
including interference that may cause undesired operation.
RX Data:
Turn LED on................ @ L 1
Turn LED off............... @ L 0
Toggle LED................. @ L 2
(Bi-Color LED Turns Orange)
Turn Relay on.............. @ R 1
Turn Relay off............. @ R 0
Enable Format Processing... @ P 1
(Outputs Badge Num,Site Code,Fixed Code for recognized formats only)
Disable Format Processing.. @ P 0
(Outputs Decimal Representation of all card bits)
Communications:
9600 BPS ASYNC, 8 bits, 1 Stop, No Parity
Cables
3
2
5
2
3
5
TX
RX
Gnd
RX
TX
Gnd
Computer
DB-9
Female
3
2
5
3
2
7
TX
RX
Gnd
RX
TX
Gnd
Computer
DB-25
Female
CVT-2240
DB-9
Male
3
2
5
2
3
7
TX
RX
Gnd
RX
TX
Gnd
Printer
DB-25
Male
CVT-2240
DB-9
Male
CVT-2240
DB-9
Male
Input Characteristics of CVT-2240
Data 1
Data 0
1 ms (typ.)
50 s (typ)
16383 0 65535
Site Code
1..16383
Badge Number
1..65535
End of Text {$03}
Start of Text {$02}
stx
etx
TX Data:
Always 0
nul nul
stx = $2
etx = $3
nul = $0
12345678901234567890123456789012345678901234
xxxxxxxSSSSSSSSSSSSSSBBBBBBBBBBBBBBBBxxxxxxx
The above output would result from the following input:
xxxxxxx111111111111111111111111111111111111x
190512
Cypress Computer Systems, Inc. 1778 Imlay City Road Lapeer, MI 48446
TX(810)245-2300 FX(810)245-2332 www.cypresscom.com