ChipFind - документация

Электронный компонент: G7L-1A-T100/120VAC

Скачать:  PDF   ZIP
Power Relay
G7L
A High Capacity, High-withstand
-voltage Relay Resistant to Momentary
Voltage Drops
No contact chattering for momentary voltage drops
up to 50% of rated voltage.
Wide-range AC-activated coil that handles 100 to
120 and 200 to 240 VAC at either 50 or 60Hz.
Miniature hinge for maximum switching capacity,
particularly for inductive loads.
Contact gap of 3mm minimum assures stable
switching of 20A minimum at 200 VAC.
Flame resistant materials (UL94V0) used for all
insulation material.
Quick-connect, screw and PCB terminals
available.
Standard models are UL, CSA, VDE and IEC
approved.
Ordering Information
Mounting type
Contact form
PCB terminals
PCB mounting
SPSTNO
G7L1AP
DPSTNO
G7L2AP
Rated coil voltage
Note:
When ordering, add the rated coil voltage to the model
number.
Example: G7L-1A-P 6 VAC
Model Number Legend:
G7L - -
1
2
3 4
1. Contact Form
1A:
SPSTNO
2A:
DPSTNO
2.* Terminal Shape
P:
PCB terminals
T:
Quick-connect terminals
B:
Screw terminals
3. Mounting Construction
None:Ebracket
UB:
Upper bracket
4. Special Functions
None:Standard mode
J:
with test button
5. Rated Coil Voltage
AC:
6, 12, 24, 50, 100 to 120,
200 to 240
DC:
6, 12, 24, 48, 100
*Note: Screw and Quick-con-
nect terminals are also avail-
able, please contact OMRON.
5
Application Examples
Compressors for air conditioners and heater
switching controllers.
Switching controllers for power tools or motors.
Power controllers for water heaters.
Lamp controls, motor drives and power suppply
switching in copy machines, facsimiles and other
office equipment.
Power controllers for packers or food processing
equipment.
Power controllers for dryers.
Lighting controllers.
Magnetron control in microwaves.
Specifications
Coil Ratings
Rated voltage
Rated cur-
rent
Coil resistance
Must operate
voltage
Must release
voltage
Max. voltage
Power con-
sumption
AC
6 VAC
283 mA
-
75% max. of
rated voltage
15% min. of
rated voltage
110% of rated
voltage
Approx. 1.7 to
2 5VA
12 VAC
142mA
-
rated voltage
rated voltage
voltage
2.5VA
24 VAC
71mA
-
50 VAC
34mA
-
100 to 200 VAC
17.0 to
20.4mA
-
75 V
18 V
132 V
200 to 240 VAC
8.5 to
10.2mA
-
150 V
32 V
264 V
DC
6 VDC
317mA
18.9
75% max. of
rated voltage
15% min. of
rated voltage
110% of rated
voltage
Approx. 1.9 W
12 VDC
158mA
75
rated voltage
rated voltage
voltage
24 VDC
79mA
303
48 VDC
40mA
1220
100 VDC
19mA
5260
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
_
C with tolerances of +15%/20% for AC rated
current and
15% for DC coil resistance.
2. Performance characteristic data is measured at a coil temperature of 23
_
C.
Contact Ratings
Model
G7L1AP/G7L2AP
Resistive load
(cos
=1)
Inductive load
(cos
=0.4)
Rated load
20A, 220 VAC
Rated carry current
20A
Max. switching
voltage
250 VAC
Max. switching
current
20A
Max. switching
capacity
4,400 VAC
Min. permissble
load *
100 mA, 5 VDC
*Note: P level:
60
=0.1 x 10
6
/operation
Characteristics
Contact resistance
50m
max.
Operate time
30 ms max.
Release time
30 ms max.
Max. operating frequency
Mechanical: 1,800 operations/hr
Electrical:
1,800 operations/hr (under rated load)
Insulation resistance
1,000 M
min. (at 500 VDC)
Dielectric withstand voltage
4,000 VAC min./5,000 VAC typ., 50/60Hz for 1 minute between coil and contacts
2,000 VAC, 50/60Hz for 1 minute between contacts of same polarity
2,000 VAC, 50/60Hz for 1 minute between contacts of different polarity (DPSTNO type)
Impulse withstand voltage
10,000 V* between coil and contact
Vibration resistance
Destruction: 10 to 55Hz, 1.5mm double amplitude
Malfunction: 10 to 55Hz, 1.5mm double amplitude
Shock resistance
Destruction: 1,000 m/s2 (approx. 100G)
Malfunction: 100 m/s2 (approx. 10G)
Life expectancy
Mechanical: 1,000,000 operations min. (at 1,800 operations/hr)
Electrical:
100,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature
Operating:
25
_
C to 60
_
C (with no icing)
Ambient humidity
Operating:
35% to 85%
Weight
PCB Terminal Type: approx. 100g
Note:
1. The values given are intial values.
2.* Impulse wave used: 1.2 x 50
s
Approved by Standards
UL 508 Recognitions (File No. E41643)/
CSA22.2 No. 14 Listings (File No. LR35535)
Coil ratings
Contact ratings
PCB terminals
6 to 265 VAC
6 to 220 VDC
20A
277 VAC, Resistive
20A
277 VAC, General use
1.5KW
120 VAC, Tungsten
1.5hp
120 VAC
3.0hp
240/265/277 VAC
20 FLA/120 LRA
120 VAC
17 FLA/102 LRA
277 VAC
TV10
120 VAC
VDE 0435, IEC 255, IEC 950 (TUV: File No.
R9051158; Pollution Degree 3, Overvoltage
Category III)
Coil ratings
Contact ratings
PCB terminals
SPSTNO
DPSTNO
6, 12, 24, 48, 100,
110, 200, 220
VDC
6, 12, 24, 50,
100/120, 200/240
VAC
20A, 240VAC
(cos
=1)
20A, 240VAC
(cos
=0.4)
20A, 240VAC
(cos
=1)
20A, 240VAC
(cos
=0.4)
Engineering Data
G7L1AP/G7L2AP
Maximum Switching
Capacity
Life Expectancy
Switching voltage (V)
Switching voltage (V)
Switching current (A)
Life expectancy (x10 operations)
AC resistive load
AC inductive load
(cos
=0.4)
220VAC resistive load
220VAC inductive
load (cos
=0.4)
3
Dimensions
G7L1AP
G7L2AP
Terminal Arrangement/
Internal Connections
(Top view)
Terminal Arrangement/
Internal Connections
(Top view)
Mounting Holes
(Bottom view)
Mounting Holes
(Bottom view)
Internal Coil Circuit
DC Operating Coil
AC Operating Coil
Precautions
Handling
To preserve performance, do not drop or otherwise subject the
Power Relay to shock.
The case is not designed to be removed during normal handling
and operation. Doing so may affect performance.
Use the Power Relay in a dry environment free from excessive
dust, SO2, H
2
S or organic gas.
Do not allow a voltage greater than the maximum allowable coil
voltage to be applied continuously.
Do not use the Power Relay outside of specified voltages and
currents.
Do not allow the ambient operating temperature to exceed the
specified limit.
Installation
Although there are not specific limits on the installation site, it
should be as dry and dust-free as possible.
PCB Terminal-equipped Relays weigh approximately 100g. Be
sure that the PCB is strong enough to support them. We
recommend dual-side through-hole PCBs to reduce solder
cracking from heat stress.
Cleaning PCB Terminals
PCB terminals have flux-tight construction which prevents flux from
penetrating into the relay base housing e.g. due to capillary action
up the terminals when the relay is soldered onto the PC board. This
type of relay cannot be immersed for cleaning.
Operating Coil
As a rule, either a DC battery or a DC power supply with a
maximum of 5% ripple is used for the operating voltage for DC
relays. Before using a rectified AC supply, confirm that the ripple
is not greater than 5%. Ripple greater than this can lead to
variations in the operating and reset voltages.
An excessive ripple can generate pulses, the insertion of a
smoothing capacitor is recommended as shown below.
% of ripple= ______________ x 100
E max.: Max. ripple
E min.: Min. ripple
E mean: Mean DC value
E max.E min.
E mean
Relay
Smoothing
capacitor
E min.E max.E mean
DC fraction
When driving a transistor, check the leakage current and
connect a bleeder resistor if necessary.