ChipFind - документация

Электронный компонент: BTS410F2

Скачать:  PDF   ZIP
PROFET BTS 410 F2
Semiconductor Group
1 of 15
2003-Oct-01
Smart Highside Power Switch
Features
Overload protection
Current limitation
Short circuit protection
Thermal shutdown
Overvoltage protection (including load dump)
Fast demagnetization of inductive loads
Reverse battery protection
1
)
Undervoltage and overvoltage shutdown with
auto-restart and hysteresis
Open drain diagnostic output
Open load detection in ON-state
CMOS compatible input
Loss of ground and loss of V
bb
protection
Electrostatic discharge (ESD) protection
Application
C compatible power switch with diagnostic feedback for 12 V and 24 V DC grounded loads
Most suitable for inductive loads
Replaces electromechanical relays, fuses and discrete circuits
General Description
N channel vertical power FET with charge pump, ground referenced CMOS compatible input and diagnostic
feedback, monolithically integrated in Smart SIPMOS
technology. Providing embedded protective functions.
+ Vbb
IN
ST
Signal GND
ESD
PROFET
OUT
GND
Logic
Voltage
sensor
Voltage
source
Open load
detection
Short circuit
detection
Charge pump
Level shifter
Temperature
sensor
Rectifier
Limit for
unclamped
ind. loads
Gate
protection
Current
limit
2
4
1
3
5
Load GND
Load
V
Logic
Overvoltage
protection
1
) With external current limit (e.g. resistor R
GND
=150
) in GND connection, resistors in series with IN and ST
connections, reverse load current limited by connected load.
Product Summary
Overvoltage protection
V
bb(AZ)
65
V
Operating voltage
V
bb(on)
4.7 ... 42 V
On-state resistance
R
ON
220 m
Load current (ISO)
I
L(ISO)
1.8
A
Current limitation
I
L(SCr)
2.7
A
TO-220AB/5
5
Standard
1
5
Straight leads
1
5
SMD
BTS 410 F2
Semiconductor Group
2
2003-Oct-01
Pin Symbol
Function
1 GND
-
Logic
ground
2
IN
I
Input, activates the power switch in case of logical high signal
3 Vbb
+
Positive power supply voltage,
the tab is shorted to this pin
4
ST
S
Diagnostic feedback, low on failure
5 OUT
(Load, L)
O
Output to the load
Maximum Ratings at T
j
= 25 C unless otherwise specified
Parameter Symbol
Values
Unit
Supply voltage (overvoltage protection see page 3)
V
bb
65
V
Load dump protection
2
)
V
LoadDump
= U
A
+ V
s
, U
A
= 13.5 V
R
I
3
)
= 2
, R
L
= 6.6
, t
d
= 400 ms, IN= low or high
V
Load dump
4
)
100
V
Load current (Short circuit current, see page 4)
I
L
self-limited
A
Operating temperature range
Storage temperature range
T
j
T
stg
-40 ...+150
-55 ...+150
C
Power dissipation (DC), T
C
25 C
P
tot
50
W
Inductive load switch-off energy dissipation, single pulse
V
bb
=
12V, T
j,start
=
150C, T
C
=
150C const.
I
L
=
1.8
A, Z
L
=
2.3
H, 0
:


E
AS
4.5
J
Electrostatic discharge capability (ESD)
IN:
(Human Body Model)
all other pins:
acc. MIL-STD883D, method 3015.7 and ESD assn. std. S5.1-1993
V
ESD
1
2
kV
Input voltage (DC)
V
IN
-0.5 ... +6
V
Current through input pin (DC)
Current through status pin (DC)
see internal circuit diagrams page 6
I
IN
I
ST
5.0
5.0
mA
Thermal Characteristics
Parameter and Conditions Symbol
Values
Unit
min typ
max
Thermal resistance
chip - case:
junction - ambient (free air):
R
thJC
R
thJA
--
--
--
--
2.5
75
K/W
SMD version, device on PCB
5
)
:
-- 35 --
2
) Supply voltages higher than V
bb(AZ)
require an external current limit for the GND and status pins, e.g. with a
150
resistor in the GND connection and a 15 k
resistor in series with the status pin. A resistor for the
protection of the input is integrated.
3
)
R
I
= internal resistance of the load dump test pulse generator
4
)
V
Load dump
is setup without the DUT connected to the generator per ISO 7637-1 and DIN 40839
5
) Device on 50mm*50mm*1.5mm epoxy PCB FR4 with 6cm
2
(one layer, 70
m thick) copper area for Vbb
connection. PCB is vertical without blown air.
BTS 410 F2
Semiconductor Group
3
2003-Oct-01
Electrical Characteristics
Parameter and Conditions Symbol
Values
Unit
at T
j
= 25 C, V
bb
= 12 V unless otherwise specified
min typ
max
Load Switching Capabilities and Characteristics
On-state resistance (pin 3 to 5)
I
L
= 1.6 A
T
j
=25 C:
T
j
=150 C:

R
ON
--
190
390
220
440
m
Nominal load current, ISO Norm (pin 3 to 5)
V
ON
= 0.5 V, T
C
= 85 C

I
L(ISO)
1.6
1.8 --
A
Output current (pin
5
) while GND disconnected or
GND pulled up, V
bb
=30 V, V
IN
= 0, see diagram
page 7, T
j
=-40...+150C
I
L(GNDhigh)
-- -- 1
mA
Turn-on time
IN
to 90% V
OUT
:
Turn-off time
IN
to 10% V
OUT
:
R
L
= 12
,
T
j
=-40...+150C
t
on
t
off
12
5
--
--
125
85
s
Slew rate on
10 to 30% V
OUT
,
R
L
= 12
,
T
j
=-40...+150C
dV /dt
on
--
--
3
V/
s
Slew rate off
70 to 40% V
OUT
, R
L
= 12
,
T
j
=-40...+150C
-dV/dt
off
--
--
6
V/
s
Operating Parameters
Operating voltage
6
)
T
j
=-40...+150C: V
bb(on)
4.7
--
42
V
Undervoltage shutdown
T
j
=25C:
T
j
=-40...+150C:
V
bb(under)
2.9
2.7
--
--
4.5
4.7
V
Undervoltage restart
T
j
=-40...+150C: V
bb(u rst)
--
--
4.9
V
Undervoltage restart of charge pump
see diagram page 13
V
bb(ucp)
-- 5.6 6.0
V
Undervoltage hysteresis
V
bb(under)
= V
bb(u rst)
- V
bb(under)
V
bb(under)
-- 0.1 --
V
Overvoltage shutdown
T
j
=-40...+150C: V
bb(over)
42
--
52
V
Overvoltage restart
T
j
=-40...+150C: V
bb(o rst)
40 -- --
V
Overvoltage hysteresis
T
j
=-40...+150C:
V
bb(over)
-- 0.1 --
V
Overvoltage protection
7
)
T
j
=-40...+150C:
I
bb
=4 mA
V
bb(AZ)
65
70
--
V
Standby current (pin 3)
T
j
=-40...+25C
:
V
IN
=0
T
j
= 150C:
I
bb(off)
--
--
10
18
15
25
A
Leakage output current (included in I
bb(off)
)
V
IN
=0
I
L(off)
-- --
20
A
Operating current (Pin 1)
8
)
, V
IN
=5 V,
T
j
=-40...+150C
I
GND
-- 1
2.1
mA
6
)
At supply voltage increase up to V
bb
= 5.6 V typ without charge pump, V
OUT
V
bb
- 2 V
7
)
Meassured without load
.
See also V
ON(CL)
in table of protection functions and circuit diagram page 7.
8
)
Add I
ST
, if I
ST
> 0, add I
IN
, if V
IN
>5.5 V
BTS 410 F2
Parameter and Conditions Symbol
Values
Unit
at T
j
= 25 C, V
bb
= 12 V unless otherwise specified
min typ
max
Semiconductor Group
4
2003-Oct-01
Protection Functions
9
)
Initial peak short circuit current limit (pin 3 to 5)
10
)
,
(
max 450
s if V
ON
> V
ON(SC)
)
I
L(SCp)
T
j
=-40C:
T
j
=25C:
T
j
=+150C:
4.0
3.5
2.0
--
5.5
3.5
11
10
7.5
A
Overload shutdown current limit
I
L(SCr)
V
ON
= 8 V, T
j
= T
jt
(see timing diagrams, page 11)
--
2.7 --
A
Short circuit shutdown delay after input pos. slope
V
ON
> V
ON(SC)
,
T
j
=-40..+150C:
min value valid only, if input "low" time exceeds 60
s

t
d(SC)
--
-- 450
s
Output clamp (inductive load switch off)
at V
OUT
= V
bb
- V
ON(CL)
I
L
= 40 mA, T
j
=-40..+150C:

V
ON(CL)
61
68 73
V
I
L
= 1 A, T
j
=-40..+150C:
--
-- 75
Short circuit shutdown detection voltage(pin 3 to 5) V
ON(SC)
--
8.5
--
V
Thermal overload trip temperature
T
jt
150 -- --
C
Thermal hysteresis
T
jt
-- 10 --
K
Reverse battery (pin 3 to 1)
11
)
-V
bb
--
--
32
V
Diagnostic Characteristics
Open load detection current
(on-condition)
T
j
=-40 ..150C:
I
L (OL)
2
-- 150
mA
9
)
Integrated protection functions are designed to prevent IC destruction under fault conditions described in the
data sheet. Fault conditions are considered as "outside" normal operating range. Protection functions are not
designed for continuous repetitive operation.
10
) Short circuit current limit for max. duration of t
d(SC) max
=450
s, prior to shutdown
11
) Requires
150
resistor in GND connection. The reverse load current through the intrinsic drain-source
diode has to be limited by the connected load. Note that the power dissipation is higher compared to normal
operating conditions due to the voltage drop across the intrinsic drain-source diode. The temperature
protection is not active during reverse current operation! Input and Status currents have to be limited (see
max. ratings page 2 and circuit page 7).
BTS 410 F2
Parameter and Conditions Symbol
Values
Unit
at T
j
= 25 C, V
bb
= 12 V unless otherwise specified
min typ
max
Semiconductor Group
5
2003-Oct-01
Input and Status Feedback
12
)
Input turn-on threshold voltage
T
j
=-40..+150 V
IN(T+)
1.5 --
2.4
V
Input turn-off threshold voltage
T
j
=-40..+150 V
IN(T-)
1.0 -- --
V
Input threshold hysteresis
V
IN(T)
-- 0.5 --
V
Off state input current (pin 2), V
IN
= 0.4 V
I
IN(off)
1
--
30
A
On state input current (pin 2), V
IN
= 5 V
I
IN(on)
10 25 70
A
Status invalid after positive input slope
(short circuit)
Tj=-40 ... +150C:
t
d(ST SC)
-- --
450
s
Status invalid after positive input slope
(open load)
Tj=-40 ... +150C:
t
d(ST)
300 --
1400
s
Status output (open drain)
Zener limit voltage T
j
=-40...+150C, I
ST
= +50 uA:
ST low voltage T
j
=-40...+150C, I
ST
= +1.6 mA:
V
ST(high)
V
ST(low)
5.0
--
6
--
--
0.4
V
12
)
If a ground resistor R
GND
is used, add the voltage drop across this resistor.