ChipFind - документация

Электронный компонент: DL4007

Скачать:  PDF   ZIP
DL4001
THRU
DL4007
1 Amp Glass
Passivated Rectifier
50 to 1000 Volts
MELF
SUGGESTED SOLDER
PAD LAYOUT
Features
Glass Passivated Junction
Low Current Leakage
Metalurgically Bonded Construction
Surface Mount Applications
DIMENSIONS
INCHES
MM
DIM
MIN
MAX
MIN
MAX
NOTE
A .185 .205 4.70 5.20
B .018 .022 0.46 0.56 Nominal
C .095 .105 2.40 2.67
Maximum Ratings
Operating Temperature: -65
C to +150
C
Storage Temperature: -65
C to +150
C
Maximum Thermal Resistance; 30
C/W Junction To Lead
MCC
Part Number
Device
Marking
Maximum
Recurrent
Peak
Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
DL4001 ------- 50V 35V 50V
DL4002 ------- 100V 70V 100V
DL4003 ------- 200V 140V 200V
DL4004 ------- 400V 280V 400V
DL4005 ------- 600V 420V 600V
DL4006 ------- 800V 560V 800V
DL4007 ------- 1000V 700V 1000V
Electrical Characteristics @ 25
C Unless Otherwise Specified
Average Forward
Current
I
F(AV)
1.0A
T
A
= 75
C
Peak Forward Surge
Current
I
FSM
30A
8.3ms, half sine
Maximum
Instantaneous
Forward Voltage
V
F
1.1V
I
FM
= 1.0A;
T
J
= 25
C*
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
R
5.0
A
50
A
T
J
= 25
C
T
J
= 125
C
Typical Junction
Capacitance
C
J
12pF Measured at
1.0MHz, V
R
=4.0V
*Pulse test: Pulse width 300
sec, Duty cycle 2%
A
B
C
Cathode Mark
.220"
.035"
.115"
www.
mccsemi
.com
omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
M C C
Average Forward Rectified Current - Amperes
versus
Ambient Temperature -
C
Figure 2
Forward Derating Curve
0
175
50
75
100
125
0
.2
.4
.6
Single Phase, Half Wave
60Hz Resistive or Inductive Load
Amps
C
150
.8
1.0
1.2
Junction Capacitance - pF
versus
Reverse Voltage - Volts
Instantaneous Forward Current - Amperes
versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
4
6
20
10
Amps
.4
.6
.8
1.0
1.2
1.4
.01
.02
.04
.06
.1
.2
.4
.6
1
2
25
C
Volts
Figure 3
Junction Capacitance
.1
.2
1
.4
2
10
20
40
4
100
200
1
2
6
10
20
100
pF
Volts
60
40
4
400
1000
T
J
=25
C
M C C
www.
mccsemi
.com
DL4001 thru DL4007
DL4001 thru DL4007
1
100
4
0
10
5
20
30
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes
versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10
20
60 80
40
40
50
60
Figure 4
Typical Reverse Characteristics
Instantaneous Reverse Leakage Current - MicroAmperes
versus
Percent Of Rated Peak Reverse Voltage - Volts
Volts
4
6
20
10
Amps
20
120
40
60
80
100
.01
.02
.04
.06
.1
.2
.4
.6
1
2
T
A
=25
C
40
60
100
140
T
A
=100
C
M C C