MURX0510
THRU
MURX0560
0.5 Amp Super Fast
Recovery Rectifier
100 to 600 Volts
Features
For Surface Mount Application
Low Leakage
Low Forward Voltage Drop
Extremely Low Thermal Resistance
Super Fast Recovery Time For High Efficiency
Maximum Ratings
Operating Temperature: -40
to +150
Storage Temperature: -40
to +150
Maximum Thermal Resistance: 200 /W Junction to Ambient
MCC
Part Number
Device
Marking
Maximum
Recurrent
Peak Reverse
Voltage
Maximum
RMS
Voltage
Maximum
DC
Blocking
Voltage
MURX0510 U1 100V 70V 100V
MURX0520 U2 200V 140V
200V
MURX0530 U3 300V 210V
300V
MURX0540 U4 400V 280V
400V
MURX0550 U5 500V 350V
500V
MURX0560 U6 600V 420V
600V
Electrical Characteristics @ 25 Unless Otherwise Specified
Average Forward
Current
I
F(AV)
0.5
A
T
L
= 115
Peak Forward Surge
Current
I
FSM
8.0A 8.3ms, half sine
Maximum
Instantaneous
Forward Voltage
V
F
1.35V
I
FM
=0.5A;
T
A
= 25
Maximum DC
Reverse Current At
Rated DC Blocking
Voltage
I
R
5.0
A T
A
= 25
Maximum Reverse
Recovery Time
T
rr
75ns
I
F
=0.5A, I
R
=1.0A,
I
rr
=0.25A
Typical Junction
Capacitance
C
J
10pF
Measured at
1.0MHz, V
R
=4.0V
*Pulse Test: Pulse Width 300
sec, Duty Cycle 2%
omponents
21201 Itasca Street Chatsworth
!"#
$ % !"#
M C C
www.
mccsemi
.com
SOD-123
0.036"
0.093"
0.048"
SUGGESTED SOLDER
PAD LAYOUT
DIMENSIONS
INCHES MM
DIM
MIN MAX MIN MAX
NOTE
A .140 .152 3.55 3.85
B .100 .112 2.55 2.85
C .055 .071 1.40 1.80
D ----- .053 ----- 1.35
E .012 .031 0.30 .78
G .006 ----- 0.15 -----
H ----- .01 ----- .25
J ----- .006 ----- .15
A
B
E
C
J
D
H
G
Average Forward Rectified Current - Amperes versus
Ambient Temperature -
C
Figure 2
Forward Derating Curve
0
175
50
75
100
125
0
.1
.2
.3
Amps
C
150
.4
. 5
.6
Junction Capacitance - pF versus
Reverse Voltage - Volts
Instantaneous Forward Current - Amperes versus
Instantaneous Forward Voltage - Volts
Figure 1
Typical Forward Characteristics
.4
.6
2.0
1.0
Amps
.4
.6
.8
1.0
1.2
1.4
.001
.002
.004
.006
.01
.02
.04
.06
.1
.2
25
C
Volts
Figure 3
Junction Capacitance
.1
.2
1
.4
2
10
20
40
4
100
200
.1
.2
.6
1
2
10
pF
Volts
6
4
.4
400
1000
T
J
=25
C
Single Phase, Half Wave
60Hz Resistive or Inductive Load
www.
mccsemi
.com
M C C
MURX0510 thru MURX0560
t
rr
+0.5A
0
-0.25
1.0
1cm
Set Time Base for 20/100ns/cm
25Vdc
1
50
10
Oscilloscope
Note 1
Pulse
Generator
Note 2
Notes:
1. Rise Time = 7ns max.
Input impedance = 1 megohm, 22pF
2. Rise Time = 10ns max.
Source impedance = 50 ohms
3. Resistors are non-inductive
Figure 6
Reverse Recovery Time Characteristic And Test Circuit Diagram
1
100
4
0
1.5
3.0
4.5
8
Figure 5
Peak Forward Surge Current
Peak Forward Surge Current - Amperes versus
Number Of Cycles At 60Hz - Cycles
Amps
Cycles
2
6
10
20
60
80
40
6.0
7.5
9.0
Figure 4
Typical Reverse Characteristics
Instantaneous Reverse Leakage Current - MicroAmperes versus
Percent Of Rated Peak Reverse Voltage - Volts
Volts
4
6
20
10
Amps
2
120
4
60
80
100
.01
.02
.04
.06
.1
.2
.4
.6
1
2
T
A
=25
C
40
60
100
140
T
A
=100
C
T
A
=150
C
www.
mccsemi
.com
M C C
MURX0510 thru MURX0560