DESCRIPTION
s
475ps propagation delay
s
2.8GHz toggle frequency
s
Internal 75K
input pull-down resistors
s
Available in 8-pin SOIC package
The SY10/100EL51 are differential clock D flip-flops
with reset. These devices are functionally similar to the
E151 devices, with higher performance capabilities. With
propagation delays and output transition times
significantly faster than the E151, the EL51 is ideally
suited for those applications which require the ultimate
in AC performance.
The reset input is an asynchronous, level triggered
signal. Data enters the master portion of the flip-flop
when the clock is LOW and is transferred to the slave,
and thus the outputs, upon a positive transition of the
clock. The differential clock inputs of the EL51 allow the
device to be used as a negative edge triggered flip-flop.
The differential input employs clamp circuitry to
maintain stability under open input (pulled down to V
EE
)
conditions.
FEATURES
DIFFERENTIAL
CLOCK D FLIP-FLOP
PIN CONFIGURATION/BLOCK DIAGRAM
PIN NAMES
Pin
Function
R
Reset Input
D
Data Input
CLK
Clock Input
Q
Data Output
SY10EL51
SY100EL51
FINAL
1
2
3
4
5
6
7
8
R
V
CC
Q
V
EE
D
Q
R
CLK
Flip-Flop
D
CLK
SOIC
TOP VIEW
D
R
CLK
Q
L
L
Z
L
H
L
Z
H
X
H
X
L
NOTE:
1. Z = LOW-to-HIGH transition.
TRUTH TABLE
(1)
1
Rev.: F
Amendment: /0
Issue Date:
February 2003
2
SY10EL51
SY100EL51
Micrel
T
A =
40
C
T
A =
0
C
T
A =
+25
C
T
A =
+85
C
Symbol
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
f
MAX
Maximum Toggle
1.8
2.8
--
2.2
2.8
--
2.2
2.8
--
2.2
2.8
--
GHz
Frequency
t
PLH
Propagation Delay to
ps
t
PHL
Output
CLK
325
465
605
375
465
555
385
475
565
440
530
620
R
305
455
605
355
455
555
355
465
565
410
510
620
t
S
Set-up Time
150
0
--
150
0
--
150
0
--
150
0
--
ps
t
H
Hold Time
250
100
--
250
100
--
250
100
--
250
100
--
ps
t
RR
Reset Recovery
400
200
--
400
200
--
400
200
--
400
200
--
ps
t
PW
Minimum Pulse Width
400
--
--
400
--
--
400
--
--
400
--
--
ps
CLK, Reset
V
PP
Minimum Input
150
--
--
150
--
--
150
--
--
150
--
--
mV
Swing
(1)
V
CMR
Common Mode
(2)
--
0.4
(2)
--
0.4
(2)
--
0.4
(2)
--
0.4
V
Range
(2)
t
r
Output Rise/Fall Times Q
100
225
350
100
225
350
100
225
350
100
225
350
ps
t
f
(20% to 80%)
AC ELECTRICAL CHARACTERISTICS
V
EE
= V
EE
(Min.) to V
EE
(Max.); V
CC
= GND
NOTES:
1. Minimum input swing for which AC parameters are guaranteed.
2. The CMR range is referenced to the most positive side of the differential input signal. Normal operation is obtained if the HIGH level falls within the specified
range and the peak-to-peak voltage lies between V
PP
min. and 1V. The lower end of the CMR range is dependent on V
EE
and is equal to V
EE
+ 3.0V.
PRODUCT ORDERING CODE
Ordering
Package
Operating
Marking
Code
Type
Range
Code
SY10EL51ZC
Z8-1
Commercial
HEL51
SY10EL51ZCTR*
Z8-1
Commercial
HEL51
SY100EL51ZC
Z8-1
Commercial
XEL51
SY100EL51ZCTR*
Z8-1
Commercial
XEL51
*Tape and Reel
DC ELECTRICAL CHARACTERISTICS
T
A =
40
C
T
A =
0
C
T
A =
+25
C
T
A =
+85
C
Symbol
Parameter
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Min.
Typ.
Max.
Unit
I
EE
Power Supply Current
mA
10EL
--
24
29
19
24
29
19
24
29
19
24
29
100EL
--
24
29
19
24
29
19
24
29
24
30
36
V
EE
Power Supply Voltage
V
10EL 4.75
5.2
5.5
4.75
5.2
5.5
4.75
5.2
5.5
4.75
5.2
5.5
100EL 4.20
4.5
5.5
4.20
4.5
5.5
4.20
4.5
5.5
4.20
4.5
5.5
I
IH
Input HIGH Current
--
--
150
--
--
150
--
--
150
--
--
150
A
V
EE
= V
EE
(Min.) to V
EE
(Max.); V
CC
= GND
Note 1.
Recommended for new designs.
Ordering
Package
Operating
Marking
Code
Type
Range
Code
SY10EL51ZI
(1)
Z8-1
Industrial
HEL51
SY10EL51ZITR*
(1)
Z8-1
Industrial
HEL51
SY100EL51ZI
(1)
Z8-1
Industrial
XEL51
SY100EL51ZITR*
(1)
Z8-1
Industrial
XEL51
*Tape and Reel
3
SY10EL51
SY100EL51
Micrel
8 LEAD SOIC .150" WIDE (Z8-1)
Rev. 03
4
SY10EL51
SY100EL51
Micrel
MICREL, INC.
1849 FORTUNE DRIVE
SAN JOSE, CA 95131
USA
TEL
+ 1 (408) 944-0800
FAX
+ 1 (408) 944-0970
WEB
http://www.micrel.com
The information furnished by Micrel in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchaser's
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchaser's own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
2003 Micrel, Incorporated.