DQ
1
DQ-RELAYS
30A POWER LATCHING
RELAY
38.0
1.496
29.0
1.142
17.3
.681
FEATURES
1. Compact with high capacity
Although compact this relay can handle
high capacity control of 30A.
2. Latching type
With latching this relay contributes to en-
ergy conservation in devices.
3. High insulation
Designed with an insulation distance of at
least 8 mm.
4. Cadmium and lead free
5. Complies with safety standards
UL, CSA and VDE approved.
SPECIFICATIONS
Contact
Coil
Arrangement
1 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
30 m
Contact material
Silver alloy
Rating
(resistive load)
Nominal switching capacity
30 A 250V AC
Max. switching power
7,500 V A
Max. switching voltage
250V AC
Max. switching current
30 A
Expected life
(min. operations)
Mechanical
(at 180 cpm)
10
6
Electrical
(Resistive load)
10
4
*
1
Nominal operating power
1 coil latching
800 mW
2 coil latching
1,600 mW
Characteristics
Max. operating speed
(at rated load)
180 cpm
Initial insulation resistance*
2
Min. 1,000 M
(at 500 V DC)
Initial breakdown
voltage*
3
Between open
contacts
1,500 Vrms for 1 min.
Between contacts
and coil
4,000 Vrms for 1 min.
Surge voltage between contact and
coil*
4
Min. 10,000 V (initial)
Operate time [Set time]*
5
(at 20
C)
(at nominal voltage)
Max. 20ms
Release time [Reset time]*
5
(at 20
C)
(at nominal voltage)
Max. 20ms
Temperature rise (at 65
C)*
6
Max. 50
C
Shock
resistance
Functional*
7
Min. 200 m/s
2
{20 G}
Destructive*
8
Min. 1,000 m/s
2
{100 G}
Vibration
resistance
Functional*
9
10 to 55Hz
at double amplitude of 1.5mm
Destructive
10 to 55Hz
at double amplitude of 2.0mm
Conditions for
operation,
transport and
storage*
10
(Not freezing and
condensing at
low temperature)
Ambient
temperature*
11
40
C to +65
C
40
F to +149
F
Humidity
5 to 75% R.H.
Unit weight
Approx. 35 g
1.23 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
At nominal switching capacity, operating frequency: 3s ON, 3s OFF
*
2
Measurement at same location as "Initial breakdown voltage" section.
*
3
Detection current: 10mA
*
4
Wave is standard shock voltage of
1.2
50
s according to JEC-212-1981
*
5
Excluding contact bounce time.
*
6
By resistive method, max. switching current
*
7
Half-wave pulse of sine wave: 11 ms; detection time: 10
s
*
8
Half-wave pulse of sine wave: 6 ms
*
9
Detection time: 10
s
*
10
Refer to 5. Usage, transport and storage conditions mentioned in NOTES
*
11
Under the packing condition, allowable temperature range is from 40 to +65
C
40
to +149
F
.
TYPICAL APPLICATIONS
Time switches
Electric water heaters
Remote control of electric power meters
dq.fm 1 y [ W Q O O P N P Q
P P oe @ j oe @
R
R O "
DQ
2
ORDERING INFORMATION
Operating function
Contact capacity
1: 1 coil latching
2: 2 coil latching
3: 30 A
Terminal shape
Q: 250 Faston terminal
Contact characteristics
0: Standard contact
Coil voltage (DC)
4H: 4.5 V
06: 6 V
09: 9 V
12: 12 V
24: 24 V
ADQ
3
Q
0
TYPES AND COIL DATA (at 20
C
68
F
)
1 coil latching type
2 coil latching type
Contact
arrangement
Part No.
Nominal
voltage,
V DC
Set voltage,
max. V DC
(initial)
Reset voltage,
max. V DC
(initial)
Coil
resistance,
(
10%)
Nominal
operating
current, mA
(
10%)
Nominal
operating
power, mW
Max. allowable
voltage,
V DC
1 Form A
ADQ13Q04H
4.5
3.15
3.15
25.3
177.8
800
5.85
ADQ13Q006
6
4.2
4.2
45
133.3
800
7.8
ADQ13Q009
9
6.3
6.3
101
88.9
800
11.7
ADQ13Q012
12
8.4
8.4
180
66.7
800
15.6
ADQ13Q024
24
16.8
16.8
720
33.3
800
31.2
Contact
arrangement
Part No.
Nominal
voltage,
V DC
Set
voltage,
max.
V DC
(initial)
Reset
voltage,
max.
V DC
(initial)
Coil resistance,
(
10%)
Nominal operating
current, mA (
10%)
Nominal operating
power, mW
Max. allowable
voltage,
V DC
Set coil
Reset
coil
Set coil
Reset
coil
Set coil
Reset
coil
1 Form A
ADQ23Q04H
4.5
3.15
3.15
12.7
12.7
355.6
355.6
1,600
1,600
5.85
ADQ23Q006
6
4.2
4.2
22.5
22.5
266.7
266.7
1,600
1,600
7.8
ADQ23Q009
9
6.3
6.3
50.6
50.6
177.8
177.8
1,600
1,600
11.7
ADQ23Q012
12
8.4
8.4
90
90
133.3
133.3
1,600
1,600
15.6
ADQ23Q024
24
16.8
16.8
360
360
66.7
66.7
1,600
1,600
31.2
DIMENSIONS
mm
inch
General tolerance:
0.3
.012
38.0
1.496
0.8
.031
0.8
.031
0.8
.031
5.08
.200
10.16
.400
20.32
.800
0.8
.031
3.6
.142
250 faston terminal
35.8
1.409
6.35
.250
0.4
.016
0.4
.016
1.5
.059
1.8
.071
25.4
1.000
5.08
.200
5.08
.200
1.5
.059
3.3 dia.
.130 dia.
1.7 dia.
.067 dia.
29.0
1.142
40.1
1.579
4.5
.177
3.7
.146
17.3
.681
0.3
.012
21.4
.843
7.9
.311
6.9
272
Schematic (Bottom view)
Note) Terminal No.3 is only for 2 coil latching
type.
PC board pattern (Bottom view)
Tolerance:
0.1
.004
6
7
Reset
coil
Set
coil
+
1
5
4
3
2
10.16
.400
15.24
.600
5.08
.200
5.08
.200
5.08
.200
4-2.0 dia.
4-.079 dia.
3-1.5 dia.
3-.059 dia.
25.4
1.000
dq.fm 2 y [ W Q O O P N P Q
P P oe @ j oe @
R
R O "
DQ
3
NOTES
1. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be rectangular.
If it includes ripple, the ripple factor should
be less than 5%. However, check it with
the actual circuit since the characteristics
may be slightly different.
2. Coil connection
When connecting coils, refer to the wiring
diagram to prevent mis-operation or mal-
function.
3. Soldering
We recommend the following soldering
conditions
Soldering: 300
C
572
F
, max. 5 s
4. Others
1) If the relay has been dropped, the ap-
pearance and characteristics should al-
ways be checked before use.
2) The cycle lifetime is defined under the
standard test condition specified in the
JIS* C 5442-1996 standard (temperature
15 to 35
C
59 to 95
F
, humidity 25 to
75%). Check this with the real device as it
is affected by coil driving circuit, load type,
activation frequency, activation
phase,ambient conditions and other fac-
tors.
Also, be especially careful of loads such
as those listed below.
(1) When used for AC load-operating and
the operating phase is synchronous.
Rocking and fusing can easily occur due
to contact shifting.
(2) High-frequency load-operating
When high-frequency opening and clos-
ing of the relay is performed with a load
that causes arcs at the contacts, nitrogen
and oxygen in the air is fused by the arc
energy and HNO
3
is formed. This can cor-
rode metal materials.
Three countermeasures for these are listed
here.
1. Incorporate an arc-extinguishing cir-
cuit.
2. Lower the operating frequency
3. Lower the ambient humidity
3) For secure operations, the voltage ap-
plied to the coil should be nominal volt-
age. In addition, please note that pick-up
and drop-out voltage will vary according
to the ambient temperature and operation
conditions.
4) Heat, smoke, and even a fire may occur
if the relay is used in conditions outside of
the allowable ranges for the coil ratings,
contact ratings, operating cycle lifetime,
and other specifications. Therefore, do
not use the relay if these ratings are ex-
ceeded. Also, make sure that the relay is
wired correctly.
5) Incorrect wiring may cause unexpected
events or the generation of heat or flames.
6) Check the ambient conditions when
storing or transporting the relays and de-
vices containing the relays. Freezing or
condensation may occur in the relay,
causing functional damage. Avoid sub-
jecting the relays to heavy loads, or strong
vibration and shocks.
5. Usage, transport and storage condi-
tions
1) Ambient temperature, humidity, and at-
mospheric pressure during usage, trans-
port, and storage of the relay:
(1) Temperature:
40 to +65
C
40 to +149
F
(2) Humidity: 5 to 75% RH
(Avoid freezing and condensation.)
The humidity range varies with the tempera-
ture. Use within the range indicated in the
graph below.
(3) Atmospheric pressure: 86 to 106 kPa Tem-
perature and humidity range for usage, trans-
port, and storage:
2) Condensation
Condensation forms when there is a sud-
den change in temperature under high
temperature and high humidity conditions.
Condensation will cause deterioration of
the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the tempera-
tures is lower than 0
C
32
F
. This causes
problems such as sticking of movable
parts or operational time lags.
4) Low temperature, low humidity environ-
ments
The plastic becomes brittle if the relay is
exposed to a low temperature, low humid-
ity environment for long periods of time.
,
,,,
,,,,,
,,,,,,,
,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,,
,,,,,,,,,
,,,,,,,
,,,,,
,,,
Humidity, %RH
Temperature,
C
F
Tolerance range
75
5
0
+32
65
+119
40
40
(Avoid
condensation
when used at
temperatures higher
than 0
C
32
F
)
(Avoid freezing
when used at
temperatures lower
than 0
C
32
F
)