ChipFind - документация

Электронный компонент: AMP1009

Скачать:  PDF   ZIP

Document Outline

10
MOTION-DETECTING
SENSOR
(PASSIVE INFRARED TYPE)
AMP Series
Motion-Detecting Sensor (AMP)
ORDERING INFORMATION
FEATURES
TYPICAL APPLICATIONS
Detects even slight motion of a per-
son (e.g. a 20 cm
7.87 inch
move-
ment of the hand)
With our unique motion detector--high-
ly sensitive type, even slight motions
made by people will be detected easily.
Compact lens
We have decreased the exposed por-
tion of the lens, and at the same time
maintained a detection ability that is as
good or better than other motion sen-
sors on the market.
Lens dimensions:
Standard sensitive type
16
20 mm
.630
.787 inch
TYPES
PERFORMANCE
Highly sensitive type
24
24 mm
.945
.945 inch
High detection ability
This sensor is a stable, sensitive sensor
that detects 2C
3.6F
temperature
changes regardless of the location or
speed of the subject. In other words,
this sensor ensures detection whether a
person is at the edge of the detection
area or in the middle, regardless of how
fast they are moving.
Low current consumption
The standard model consumes 260 A
(during stand-by), while the low con-
sumption current type consumes 30 A
(during stand-by). This makes battery
operation possible.
Wide operation voltage range (2.6 to
5.5 V DC)
The usable range extends from a
standard 5 V DC for microcomputers to
3 V DC and 4.5 V DC for battery opera-
tion.
Varied operation in accordance with
the surrouding brightness
If used together with a brightness
sensor (CdS), you can make the sensor
operate only during bright hours or dark
hours.
Output time can easily be changed
By simply changing the resistor
attached to the outside of the sensor,
the output time can be changed from
approximately 10 seconds to 6 minutes.
Lighting and ventilation control of con-
ference rooms
Control of illumination and exhaust fans
in toilets
Lighting control of halls
Nighttime lighting control of vending
machines
Lightning control around cash dispens-
ing machines (ATMs)
0
9
Detection performance
Current consumption
Lead wire
Operating voltage
1: Standard sensitive type: 0.3 to 2.0 m/s
2: Highly sensitive type: 0.3 to 1.0 m/s
0: Standard type
1: Low current consumption type
0: No lead wire type
9: 2.6 to 5.5 V DC
Ex. AMP
Detection
performance
Standard
sensitive type
Highly
sensitive type
Current consumption
Standard type
Low current consumption type
Standard type
Low current consumption type
Rated operating voltage
2.6 to 5.5 V DC
Part No.
AMP1009
AMP1109
AMP2009
AMP2109
Packing quantity
Inner
Outer
20 pcs.
200 pcs.
1. Detection performance
(Measuring conditions: ambient temp.: 25
C
77
F
; operating voltage: 5V DC)
2. Absolute maximum rating
(Measuring condition: ambient temp.: 25
C
77
F
)
Items
Rated detection distance
Detection
range
Horizontal
Vertical
Detection zone
Standard sensitive type
5 m min.
95
55
34 zones
Highly sensitive type
2 m min.
73
73
64 zones
Conditions of objects to be detected
1. To have more than 2
C
36
F
of temperature
1.
difference from background
2. Movement speed
Standard sensitive type: 0.3 to 2.0 m/s
Highly sensitive type: 0.3 to 1.0 m/s
3. Detection object = human body
Items
Power supply voltage
Output
(Open collector)
Voltage
Usable ambient temperature
Storage temperature
Specified value
7 V
30 V
Current
50 mA
20 to +55
C
4 to +131
F
30 to +80
C
22 to +176
F
No freezing and condensing at low temperature.
Remarks
AMP series 2002.10.23 7:57 PM Page 10
11
X-Y crross section
Y
3m
9.843ft
2
6.562
1
3.281
0
1
3.281
2
6.562
3
9.843
4m
13.123ft
1
3.281
2
6.562
3
9.843
4m
13.123ft
1
3.281
2
6.562
3m
9.843ft
X
47
25.4
47
5m
16.404ft
X
Y
5m
16.404ft
2.5m
8.202ft
2.5m
8.202ft
5m
16.404ft
5m
16.404ft
2.5m
8.202ft
2.5m
8.202ft
25.4
28.7
28.7
0
0
TOP VIEW
SIDE VIEW
3. Electrical characteristics
(Measuring conditions: ambient temp.: 25
C
77
F
; operating voltage: 5V)
Items
Rated operating voltage
Rated
consumption
current
Mask time*
Circuit stability time
Timer time
Standby
ON
Minimum
Typical
Maximum
Minimum
Typical
Maximum
Minimum
Typical
Maximum
Minimum
Typical
Maximum
Minimum
Typical
Maximum
Minimum
Typical
Maximum
Sym-
bol
V
dd
I
w
I
a
T
m
T
wu
T
d
Specified value
Measured conditions
2.6 V DC
--
5.5 V DC
Standard type: 200
A; Low consumption current type: 12
A
Standard type: 260
A; Low consumption current type: 30
A
Standard type: 560
A; Low consumption current type: 96
A
Standard type: 1,000
A; Low consumption current type: 1,000
A
Standard type: 1,250
A; Low consumption current type: 1,200
A
Standard type: 1,600
A; Low consumption current type: 1,400
A
0.8 s
1.3 s
1.8 s
15 s
30 s
45 s
5 s
10 s
15 s
When power is ON.
Externally mounted
resistor R set to 0 k
DETECTION PERFORMANCE
1. Standard sensitive type
[Timing chart]
Top view
Side view
Motion-Detecting Sensor (AMP)
AMP series 2002.10.23 7:57 PM Page 11
DataSheet4U.com
12
1.5m
4.921ft
1m
3.281ft
2m
6.562ft
1
3.281
0.5
1.640
0
0.5
1.640
1
3.281
1.5m
4.921ft
1m
3.281ft
2m
6.562ft
31.2
X
31.2
11.1
11.1
0
1.5m
4.921ft
1m
3.281ft
2m
6.562ft
1
3.281
0.5
1.640
0
0.5
1.640
1
3.281
1.5m
4.921ft
1m
3.281ft
2m
6.562ft
31.2
Y
31.2
11.1
11.1
0
X-Y cross section
Y
X
0.5
1.640
0.5
1.640
1.5m
4.921ft
1.5m
4.921ft
0
0.5
1.640
0.5
1.640
1
3.281
1.5m
4.921ft
1
3.281
1.5m
4.921ft
HOW TO USE
Top view
Side view
1. Wiring diagram
2. Highly sensitive type
2. Time setting
Standard sensitive type/Highly sensitive type
Timer time and external mounted resistor
3. Installation
Install the sensor so that people will be enter-
ing from the X or Y direction shown below. If
persons approch the sensor from the Z direc-
tion, detection distance will be shortened.
Time calculation:
T
d
= 0.3465
(20+R)
R: External mounted resistor (K
)
Sensor module
Motion-Detecting Sensor (AMP)
DIMENSIONS
mm
inch
1. Standard sensitive type
2. Highly sensitive type
43.5
1.713
4-2.5 dia.
4-.098 dia.
22.5
.886
20
.787
16
.630
35.8
1.409
14.0
.551
1.6
0.3
.063
.012
28
1.102
26.8
1.055
49
1.929
43.5
1.713
4-2.5 dia.
4-.098 dia.
21.6
.850
17.6
.693
8.5
.335
R11.3
.445
R14.1
.555
11.25
.443
22.5
.886
43.5
1.713
4-2.5 dia.
4-.098 dia.
22.5
.886
43.5
1.713
18.3
.720
22.5
.886
24
.945
26.8
1.055
24
.945
18.4
.724
1.6
.063
28
1.102
25.6
1.008
25.6
1.008
18.3
.720
7.0
.276
11.25
.443
3.4
0.3
.134
.012
35.8
1.409
49
1.929
4-2.5 dia.
4-.098 dia.
15.3
.602
General tolerance: 0.4
.016
General tolerance: 0.4
.016
Note 1: In order to ensure proper detection, install it with
the lens exposed at least 8.5 mm
.335 inch.
Note 2: In order to ensure proper detection, install it with
the lens exposed at least 7.0 mm
.276 inch.
3.4
0.3
.134
.012
Timer time (Td)
10 sec.
8.86 K
Short
30 sec.
66.6 K
68 K
1 min.
153.2 K
160 K
2 min.
326.3 K
330 K
3 min.
499.5 K
510 K
4 min.
672.6 K
680 K
5 min.
845.8 K
820 K
6 min.
1,019 K
1 M
R-value
External mounted
resistor
Note Timer time, 1 sec. is available as a custom
ordered product.
Load power
source
Sensor power
source
15.3
.602
AMP series 2002.10.23 7:57 PM Page 12
CAUTIONS WHEN USING
This product is mainly designed for use
indoors with general electronic devices.
If it is to be used outdoors, take suitable
precautions to protect it from water, dust,
dew condensation, and freezing.
Example:
1. Safety devices
2. Security equipment
3. Traffic signal equipment
4. Miscellaneous safety devices and
control equipment for trains,
automobiles.
1. Operation environment
1) Shown below are ambient tempera-
ture, humidity and air pressure condi-
tions for operation, transportation, and
storage of the sensor.
Usable ambient temperature:
20 to 55C
4 to +131F
Storage temperature:
30 to 80C
22 to +176F
Humidity: 15 to 85% R.H.
(with no freezing and condensation)
Air pressure: 86 to 106 kPa
Condensation
Condensation may occur if the relay
is exposed to sudden temperature
change in a high-temperature, high-
humidity environment. This may
result in problems such as sensing
performance deterioration, non-
operation or insulation failure.
Freezing
At temperature below 0C
32F
, con-
densation and moisture may freeze
onto the sensor and cause problems
such as sensing performance
deterioration, non-operation or insula-
tion failure.
Low-temperature, low-humidity
atmosphere
If the relay is exposed to a low-
temperature, low-humidity environ-
ment for an extended period of time,
the plastic components may become
brittle and fragile.
2) Be sure to use a stable power source
for the sensor. The sensor may operate
incorrectly if it receives voltage ripples of
more than 40 mV P-P.
3) Be sure to employ an absorber ele-
ment to prevent the internal circuit from
being destroyed if an external voltage
surge of more than 500 V occurs (mono-
polarized all-wave voltage of 1.2
50
sec).
4) Static electricity or lightning may
cause the sensor to operate incorrectly.
5) Avoid using the sensor in the following
locations:
Locations exposed to direct sunlight
or other bright light sources.
Locations where a heater lies within
the detection range.
Locations subject to direct air from an
air conditioner.
Locations with high humidity (e.g.,
bathrooms, etc.).
Locations subject to sudden, extreme
temperature changes.
Locations subject to strong vibrations
or shocks.
Locations containing objects that
block infra-red rays such as glass.
Locations where blinds or curtains are
located near the detection range.
Locations near to a heat source or
switching device.
Locations containing dust or corrosive
gases.
Outdoors.
2. Detection characteristics
1) Since this sensor works by detecting
fluctuations in infrared rays, it will also
detect non-human heat sources (e.g.,
small animals, etc.) if they enter the
detection range.
2) Since this sensor works by detecting
fluctuations in infra-red rays, it will not
detect a person that is motionless, even
if within the detection range.
3. Drop damage
If the sensor is dropped, damage can
occur resulting in incorrect operation. If
dropped, be sure to do a visual check of
the exterior for noticeable damage and
check the operation characteristics for
faulty operation.
4. Other handling cautions
1) When installing the sensor, be sure
not to apply stress to the printed circuit
board.
2) Be careful not to allow dust or dirt to
accumulate on the lens as this will adver-
sely affect the detection sensitivity.
3) When soldering the lead wire, perform
the operation within 3 seconds at 350C
662F
.
4) In order to avoid adverse effects from
noise, we recommend the use of
shielded wire when wiring.
5) In order to protect the internal cir-
cuitry, keep wire to a length of 1 m
3.3 ft
maximum from the sphere.
Motion-Detecting Sensor (AMP)
AMP series 2002.10.23 7:57 PM Page 13
12/1/2002
All Rights Reserved, Copyright Matsushita Electric Works, Ltd.
Go To Online Catalog