ChipFind - документация

Электронный компонент: APE10012

Скачать:  PDF   ZIP

Document Outline

211
PE-RELAYS
VDE
Pending
THE SLIM POWER RELAY
28
1.102
15
.591
5
.197
FEATURES
Slim size
28 mm (L)
5 mm (W)
15 mm (H)
1.102 inch (L)
.197 inch (W)
.591 inch
(H)
permits high density mounting
Wide switching capacity:
100 mA/12 V DC-6A/250 V AC
High sensitivity: 170mW
High breakdown (4,000 V) and surge
(6,000 V) voltage between contacts
and coil
Clearance/creepage distance: 8/8 mm
1 Form A/1 Form C contact.
Insulation complying to following standards:
EN 60255 General specification for electrical relays
EN 60335 For use in house-hold appliances
EN 60730 For use in temperature sensing appliances
EN 60950 For use in electrical business equipment
EN 60065 For use in entertainment electronics
(radio, HiFi-sets)
EN 50178 For use in industrial range
SPECIFICATIONS
Contacts
Coil (at 25
C
77
F
, 50% R.H.)
Characteristics
Arrangement
1 Form A, 1 Form C
Contact material
Silver alloy
Au-plated
silver alloy
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
100 m
30 m
Rating (resis-
tive)
Nominal switching capacity
6 A 250 V AC
Maximum switching power
1,500 VA
Maximum switching voltage
400 V AC/300 V DC
Max. switching current
6 A (AC)
Expected life
(min.opera-
tions)
Mechanical (at 180 cpm)
5
10
6
Electrical (at 6 cpm)
(at rated load)
N.O.: 5
10
4
N.C.: 3
10
4
Nominal operating power
170 mW (4.5 to 24 V DC)
217 mW (48 V DC)
Initial insulation resistance*
1
Min. 1,000 M
at 500 V DC
Initial breakdown
voltage*
2
Between open
contacts
1,000 Vrms
Between con-
tacts and coil
4,000 Vrms
Surge voltage between contacts and
coil*
3
Min. 6,000 V (Initial)
Operate time*
4
(at nominal voltage)
Max. 8 ms (approx. 5 ms)
Release time (without diode)*
4
(at nominal voltage)
Max. 4 ms (approx. 2.5 ms)
Temperature rise
Max. 30
C with nominal coil
voltage across
coil and at nominal switching
capacity
Shock resistance
Functional*
5
1 Form C: Min. 49 m/s
2
{5 G}
1 Form A: Min. 98 m/s
2
{10 G}
Destructive*
6
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
7
10 to 55 Hz
at double amplitude of 1.0 mm/6 G
Destructive
10 to 55 Hz
at double amplitude of 1.5 mm/9 G
Conditions for operation,
transport and storage*
8
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
40
C to +85
C
40
F to +185
F
Humidity
5 to 85%R.H.
Unit weight
Approx. 4 g
.14 oz
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Intial breakdown voltage" section
*
2
Detection current: 10mA
*
3
Wave is standard shock voltage of
1.2
50
s according to JEC-212-1981
*
4
Excluding contact bounce time
*
5
Half-wave pulse of sine wave: 50ms; detection time: 10
s
*
6
Half-wave pulse of sine wave: 11ms
*
7
Detection time: 10
s
*
8
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
TYPICAL APPLICATIONS
Interface relays for programmable con-
trollers
Output relays for measuring equipment,
timers, counters and temperature con-
trollers
Industrial equipment, office equipment
House-hold appliances for Europe
ORDERING INFORMATION
Ex.
Contact arrangement
Contact type
(Notes) 1. Standard packing: Tube: 20 pcs.; Case: 1,000 pcs.
2. 5 V, 60 V type is also available.
3. 1 Form B is also available.
1: 1 Form A
3: 1 Form C
0: Single contact
Contact material
0: Silver alloy
1: Au-plated silver alloy
Coil voltage (DC)
4H: 4.5 V
06: 6 V
12: 12 V
18: 18 V
24: 24 V
48: 48 V
APE
0
PE
212
TYPES AND COIL DATA
(at 20
C
68
F
)
Part No.
Contact
arrangement
Nominal
voltage,
V DC
Pick-up
voltage,
(Initial)
V DC (max.)
Drop-out
voltage,
(Initial)
V DC (min.)
Nominal operating
current,
mA (
10%)
Nominal
operating power,
mW
Coil
resistance,
(
10%)
Max. allowable
voltage,
V DC
APE1004H
1 Form A
(without Au-
plated)
4.5
2.97
0.225
38
170
119
5.4
APE10006
6
3.96
0.3
28
212
7.2
APE10012
12
7.92
0.6
14
847
14.4
APE10018
18
11.88
0.9
9
1,906
21.6
APE10024
24
15.84
1.2
7
3,388
28.8
APE10048
48
31.68
2.4
5
217
10,618
57.6
APE1014H
1 Form A
(with Au-plated)
4.5
2.97
0.225
38
170
119
5.4
APE10106
6
3.96
0.3
28
212
7.2
APE10112
12
7.92
0.6
14
847
14.4
APE10118
18
11.88
0.9
9
1,906
21.6
APE10124
24
15.84
1.2
7
3,388
28.8
APE10148
48
31.68
2.4
5
217
10,618
57.6
APE3004H
1 Form C
(without Au-
plated)
4.5
2.97
0.225
38
170
119
5.4
APE30006
6
3.96
0.3
28
212
7.2
APE30012
12
7.92
0.6
14
847
14.4
APE30018
18
11.88
0.9
9
1,906
21.6
APE30024
24
15.84
1.2
7
3,388
28.8
APE30048
48
31.68
2.4
5
217
10,618
57.6
APE3014H
1 Form C
(with Au-plated)
4.5
2.97
0.225
38
170
119
5.4
APE30106
6
3.96
0.3
28
212
7.2
APE30112
12
7.92
0.6
14
847
14.4
APE30118
18
11.88
0.9
9
1,906
21.6
APE30124
24
15.84
1.2
7
3,388
28.8
APE30148
48
31.68
2.4
5
217
10,618
57.6
DIMENSIONS
mm
inch
1. 1 Form A type
General tolerance:
0.3
.012
0.3
.012
+0.2
0.1
+.008
.004
1.2
.047
2-0.5
2-.020
3.78
.149
21.42
.843
28.0max.
1.102max.
2-1.0
2-.039
5.04
.198
1.9
.075
3.5
.138
0.5
.020
15.0max.
.591max.
5.0max.
.197max.
1.2
.047
0.4
.016
+0.2
0.1
+.008
.004
PC board pattern (Bottom view)
Tolerance:
0.1
.004
Schematic (Bottom view)
21.42
.843
5.04
.198
1.9
.075
3.78
.149
2-1.3 dia.
2-.051 dia.
2-1.0 dia.
2-.039 dia.
1.2
.047
NO
COM
Coil
2. 1 Form C type
General tolerance:
0.3
.012
1.2
.047
2-0.5
2-.020
3.78
.149
21.42
.843
28.0max.
1.102max.
3-1.0
3-.039
5.04
.198
1.9
.075
3.5
.138
0.5
.020
15.0max.
.591max.
5.0max.
.197max.
1.2
.047
5.04
.198
0.3
.012
+0.2
0.1
+.008
.004
0.4
.016
+0.2
0.1
+.008
.004
PC board pattern (Bottom view)
Tolerance:
0.1
.004
Schematic (Bottom view)
21.42
.843
5.04
.198
1.9
.075
3.78
.149
3-1.3 dia.
3-.051 dia.
2-1.0 dia.
2-.039 dia.
1.2
.047
5.04
.198
NO
COM
Coil
NC
PE
213
REFERENCE DATA
1. Max. switching capacity
2. Coil temperature rise
Sample: APE30012
Measured portion: Inside the coil
Ambient temperature: 28
C
82
F
3. Ambient temperature characteristics
Sample: APE30012
No. of samples: n = 6
1
0.5
0.2
0.3
0.4
2
3
4
5
6
10
10
20 30 50 100
300
Contact voltage, V
Contact current, A
50
60
70
80
90
40
30
20
10
0
100
110
120
130
Coil applied voltage, %V
Temperature rise,
C
6A
0A
-20
-40
10
20
30
40
-30
-40
-20
85
60
40
0
20
-10
Ambient
temperature,
C
Pick-up voltage
Rate of
change, %
Drop-out
voltage
NOTES
Rating
Standard
File No.
Rating
UL
E43149
6 A 277 V AC
VDE
122402G
6 A 250 V AC
(cos
= 1)
1 A 250 V AC
(cos
= 0.4)
SEV
CH-99.1 10483.2A1
6 A 250 V AC
(cos
= 1)
For Cautions for Use, see Relay Technical Information (Page 48 to 76).
9/1/2000
All Rights Reserved, Copyright Matsushita Electric Works, Ltd.