1076
Sealed Subminiature Basic Switch
D2SW-P
Sealed Subminiature Basic Switch
D2SW-P
Sealed Basic Switch with Simplified
Construction, Mounting Compatible with
SS and D2SW Series.
Sealed to IEC IP67.
Switch rating of 2A at 250 VAC possible with a single-leaf
movable spring. Models for micro loads are also available.
Solder, quick-connect terminals (#110), PCB terminals and
molded lead wires are available. Even-pitched PCB
terminals are also standardized.
RoHS Compliant.
Ordering Information
I
Model Number Legend
1. Ratings
2:
2A at 250 VAC
01:
0.1A at 30 VDC
2. Actuator
None: Pin plunger
L1: Hinge
lever
L2: Hinge
roller
lever
L3: Simulated
roller
lever
3. Contact Form
None: SPDT
-2:
SPST-NC (Molded lead wire models only)
-3:
SPST-NO (Molded lead wire models only)
4. Terminals
H:
Solder terminals
T:
Quick-connect terminals (#110)
D:
PCB terminals (Uneven pitch)
B:
PCB terminals (Even pitch)
M:
Molded lead wires
I
List of Models
Note:
Consult your OMRON sales representative for details on SPST-NO and SPST-NC models.
D2SW-P
@@@@
1 2 3 4
Rating Actuator
Terminal
Solder
terminals
Quick-connect
terminals (#110)
PCB terminals
Molded lead
wires
Uneven pitch
Even pitch
2A
Pin plunger
D2SW-P2H
D2SW-P2T
D2SW-P2D
D2SW-P2B
D2SW-P2M
Hinge lever
D2SW-P2L1H
D2SW-P2L1T
D2SW-P2L1D
D2SW-P2L1B
D2SW-P2L1M
Hinge roller lever
D2SW-P2L2H
D2SW-P2L2T
D2SW-P2L2D
D2SW-P2L2B
D2SW-P2L2M
Simulated roller lever
D2SW-P2L3H
D2SW-P2L3T
D2SW-P2L3D
D2SW-P2L3B
D2SW-P2L3M
0.1A
Pin plunger
D2SW-P01H
D2SW-P01T
D2SW-P01D
D2SW-P01B
D2SW-P01M
Hinge lever
D2SW-P01L1H
D2SW-P01L1T
D2SW-P01L1D
D2SW-P01L1B
D2SW-P01L1M
Hinge roller lever
D2SW-P01L2H
D2SW-P01L2T
D2SW-P01L2D
D2SW-P01L2B
D2SW-P01L2M
Simulated roller lever
D2SW-P01L3H
D2SW-P01L3T
D2SW-P01L3D
D2SW-P01L3B
D2SW-P01L3M
Sealed Subminiature Basic Switch
D2SW-P
1077
Specifications
I
Ratings
Note:
The ratings values apply under the following test conditions.
Ambient temperature: 202C
Ambient humidity: 655%
Operating frequency: 20 operations/min.
I
Characteristics
Note: 1.
The data given above are initial values.
2.
The dielectric strength shown in the table indicates a value for models with a Separator.
3.
For the pin plunger models, the above values apply for both the free position and total travel position. For the lever models, the values
apply at the total travel position. Contact opening or closing time is within 1ms.
4.
Consult your OMRON sales representative for testing conditions.
5.
The test to meet standards checks for water intrusion after immersion for 30 minutes. The test does not check for switching operation
underwater. Refer to
"Degree of Protection"
or
"Instructions for Correct Use".
Model
Rated voltage
Resistive load
D2SW-P2
30 VDC
2 A
250 VAC
D2SW-P01
30 VDC
0.1 A
125 VAC
Item
Model
D2SW-P2
D2SW-P01
Operating speed
0.1 mm to 500 mm/s (pin plunger models)
Operating frequency
Mechanical: 120 operations/min max.
Electrical: 20 operations/min max.
Insulation resistance
100 M
min. (at 500 VDC)
Contact resistance (initial value)
Terminal models: 50 m
max.
Molded lead wire models: 100 m
max.
Terminal models: 100 m
max.
Molded lead wire models: 150 m
max.
Dielectric strength (see note 2)
1,000 VAC, 50/60 Hz for 1 min. between
terminals of the same polarities
600 VAC, 50/60 Hz for 1 min. between
terminals of the same polarities
1,500 VAC, 50/60 Hz for 1 min. between current-carrying metal parts and ground, and between
each terminal and non-current-carrying metal parts
Vibration resistance (see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance (see note 3)
Destruction: 1,000 m/s
2
{approx. 100 G} max.
Malfunction: 300 m/s
2
{approx. 30 G} max.
Durability (see note 4)
Mechanical: 1,000,000 operations min.
(60 operations/min.)
Electrical: 50,000 operations min.
(20 operations/min.)
Mechanical: 1,000,000 operations min.
(60 operations/min.)
Electrical: 200,000 operations min.
(20 operations/min.)
Degree of protection
IEC IP67 (see note 5)
(excluding the terminals on terminal models)
Degree of protection against electric shock
Class 1
Proof tracking index (PTI)
175
Ambient operating temperature
-20
C to 70C (at ambient humidity of 60% max.) (with no icing)
Ambient operating humidity
85% max. (for 5
C to 35C)
Weight
Approx. 2 g (pin plunger models with terminals)
1078
Sealed Subminiature Basic Switch
D2SW-P
I
Approved Standards
Consult your OMRON sales representative for specific models with
standard approval.
UL1054 (File No. E41515)/
CSA C22.2 No. 55 (UL approval)
I
Contact Specifications
Note:
For more information on the minimum applicable load, refer to
Using Micro Loads
in the Precautions section of this data sheet.
I
Contact Form
Note:
Lead wire colors are indicated in parentheses.
Dimensions
I
Terminals
Note: 1.
All units are in millimeters unless otherwise indicated.
2.
Terminal plate thickness is 0.5 mm for all models.
Solder Terminals
PCB Terminals (Uneven pitch)
PCB Mounting Dimensions (Reference)
Quick-connect Terminals (#110)
PCB Terminals (Even pitch)
PCB Mounting Dimensions (Reference)
Rated voltage
D2SW-P2
D2SW-P01
125 VAC
250 VAC
--
2 A
0.1 A
--
30 VDC
2 A
0.1 A
Item
Model
D2SW-P2
D2SW-P01
Contact
Specification
Rivet
Crossbar
Material
Silver alloy
Gold alloy
Gap
(standard value)
0.5 mm
Minimum applicable load
(see note)
160 mA at 5 VDC 1 mA at 5 VDC
SPDT
SPST-NC
(Molded lead wire models only)
SPST-NO
(Molded lead wire models only)
COM
NO
NC
(Black) (Blue) (Red)
COM
NC
(Black)
(Red)
COM
NO
(Black) (Blue)
NC
NC
C
0.5
6.4
0.2
3.2
2.15
8.55
9.5
0.1
19.8
0.2
3.3
0.1
5.15
7.3
15.5
Three, 1.6-dia. Holes
0.5
1.3
6.4
0.2
3.3
0.1
3-1.2
3-0.8
1.85
16.1
0.2
9.5
0.1
5.15
19.8
0.2
8.8
0.2
3.9
1.8
16.1
0.1
8.8
0.1
Three,-1.35 to 1.5 dia.
0.5
6.4
0.2
7.6
0.2
7.6
0.2
9.5
0.1
19.8
0.2
3.3
0.1
3-2.8
5.15
11
7.1
3.3
0.1
3-1.2
3-0.8
19.8
0.2
7.62
0.2
7.62
0.2
0.5
1.3
6.4
0.2
3.9
1.8
9.5
0.1
5.15
7.62
0.1
7.62
0.1
Three, 1.35 to 1.5 dia.
Sealed Subminiature Basic Switch
D2SW-P
1079
Molded Lead Wires
I
Mounting Holes
I
Dimensions and Operating Characteristics
Note: 1.
All units are in millimeters unless otherwise indicated.
2.
The following illustrations and drawings are for solder terminal models. Refer to
Terminals
section for details on models with quick-connect
terminals (#110) or PCB terminals or molded lead wires.
3.
The
@ in the model number is for the contact form code or the terminal code.
4.
Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.
5.
The operating characteristics are for operation in the A direction (
).
.
300
10
6.4
0.2
9.2
(5)
21.2
9.5
0.1
5.15
Normally closed
terminal (red)
Normally open
terminal (blue)
Common terminal (black)
0.7
Insulator
Stranded annealed
copper wites
9.5
0.1
Two, M2.3 screw hole
0.5
6.4
0.2
3.2
2.15
8.55
9.5
0.1
7.55
0.2
A
19.8
0.2
2.5
0.07
dia.
3.3
0.1
5.15
15.5
Three, 1.6 dia. holes
7.7
6.9
1.8
dia.
2.35
dia.
+0.075
-0.05
2.35
+0.075
-0.05
PT
OP
7.3
0.5
6.4
0.2
A
3.2
2.15
8.55
9.5
0.1
2.5
0.07
dia.
19.8
0.2
5.15
15.5
Three, 1.6 dia. holes
2.35
+0.075
-0.05
2.35
dia.
+0.075
-0.05
7.3
t=0.3 Stainless-steel lever
14.5
0.6
3.3
0.1
FP
OP
7.7
6.9
Pin Plunger Models
D2SW-P2
@@
D2SW-P01
@@
Model
D2SW-P2
@@
D2SW-P01
@@
OF max.
RF min.
1.8 N {183 gf}
0.2 N {20 gf}
PT max.
OT min.
MD max.
0.6 mm
0.4 mm
0.15 mm
OP
8.4
0.3 mm
Model
D2SW-P2L1
@@
D2SW-P01L1
@@
OF max.
RF min.
0.6 N {61 gf}
0.05 N {5 gf}
OT min.
MD max.
0.8 mm
0.8 mm
FP max.
OP
13.6 mm
8.8
0.8 mm
Hinge Lever Models
D2SW-P2L1
@@
D2SW-P01L1
@@
1080
Sealed Subminiature Basic Switch
D2SW-P
Precautions
I
Cautions
Degree of Protection
Do not use this product in water. Although these models satisfy the
test conditions for the standard given below, this test is to check the
ingress of water into the switch enclosure after submerging the
Switch in water for a given time. Satisfying this test condition does
not mean that the Switch can be used in water.
IEC 60529: 2001 Degrees of protection provided by enclosures (IP
Code)
Code: IP67 (The test to meet the standard checks for water intrusion
after immersion for 30 minutes.)
Do not operate the Switch when it is exposed to water spray, or when
water drops adhere to the Switch surface, or during sudden tempera-
ture changes, otherwise water may intrude into the interior of the
Switch due to a suction effect.
Prevent the Switch from coming into contact with oil and chemicals.
Otherwise, damage to or deterioration of Switch materials may
result.
Do not use the Switch in areas where it is exposed to silicon adhe-
sives, oil, or grease, otherwise faulty contact may result due to the
generation of silicon oxide.
The environment-resistant performance of the switch differs depend-
ing on operating loads, ambient atmospheres, and installation condi-
tions, etc. Please perform an operating test of the switch in advance
under actual usage conditions.
Connecting to Terminals
Connecting to Solder Terminals
When soldering the lead wire to the terminal, first insert the lead wire
conductor through the terminal hole and the conduct soldering.
Make sure that the temperature at the tip of the soldering iron is 350
to 400C. Do not take more than 3 seconds to solder the switch ter-
minal, and do not impose external force on the terminal for 1 min.
after soldering. Improper soldering involving an excessively high tem-
perature or excessive soldering time may deteriorate the characteris-
tics of the Switch.
Connecting to Quick-connect Terminals
Wire the quick-connect terminals (#110) with receptacles. Insert the
terminals straight into the receptacles. Do not impose excessive
force on the terminal in the horizontal direction, otherwise the termi-
nal may be deformed or the housing may be damaged.
Connecting to PCB Terminal Boards
When using automatic soldering baths, we recommend soldering at
2605C within 5 seconds. Make sure that the liquid surface of the
solder does not flow over the edge of the board.
When soldering by hand, as a guideline, solder with a soldering iron
with a tip temperature of 350 to 400C within 3 seconds, and do not
apply any external force for at least 1 minute after soldering. When
applying solder, keep the solder away from the case of the Switch
and do not allow solder or flux to enter the case.
Side-actuated (Cam/Dog) Operation
When using a cam or dog to operate the Switch, factors such as the
operating speed, operating frequency, push-button indentation, and
material and shape of the cam or dog will affect the durability of the
Switch. Confirm performance specifications under actual operation
conditions before using the Switch in applications.
0.5
6.4
0.2
A
3.2
2.15
8.55
9.5
0.1
2.5
0.07
dia.
19.8
0.2
5.15
15.5
Three, 1.6 dia. holes
2.35
+0.075
-0.05
2.35
dia.
+0.075
-0.05
7.3
t=0.3 Stainless-steel lever
14.5
0.6
3.3
0.1
FP
OP
7.7
6.9
dia. 4.8 x 3.2
Polyacetal resin roller
Model
D2SW-P2L2
@@
D2SW-P01L2
@@
OF max.
RF min.
0.6 N {61 gf}
0.05 N {5 gf}
OT min.
MD max.
0.8 mm
0.8 mm
FP max.
OP
19.3 mm
14.5
0.8 mm
Model
D2SW-P2L3
@@
D2SW-P01L3
@@
OF max.
RF min.
0.6 N {61 gf}
0.05 N {5 gf}
OT min.
MD max.
0.8 mm
0.8 mm
FP max.
OP
15.5 mm
10.7
0.8 mm
Hinge Roller Lever Models
D2SW-P2L2
@@
D2SW-P01L2
@@
Simulated Roller Lever Models
D2SW-P2L3
@@
D2SW-P01L3
@@
0.5
6.4
0.2
A
3.2
2.15
8.55
9.5
0.1
2.5
0.07
dia.
19.8
0.2
5.15
15.5
Three, 1.6 dia. holes
2.35
+0.075
-0.05
2.35
dia.
R1.3
+0.075
-0.05
7.3
t=0.3 Stainless-steel lever
15.8
0.6
3.3
0.1
FP
OP
7.7
6.9