General Purpose Relay
LY
D
V
E
Ordering Information
To Order: Select the part number and add the desired coil voltage rating (e.g., LY1-
DC6).
Part number
Single contact
Bifurcated contact
Standard
Upper
Lower
Standard
Upper
Lower
Contact
bracket
mounting
mounting
bracket
mounting
mounting
Type
Terminal
form
mounting
bracket
bracket
mounting
bracket
bracket
Standard
Plug-in/solder
SPDT
LY1
LY1F
LY1S
--
--
--
DPDT
LY2
LY2F
LY2S
LY2Z
LY2ZF
LY2ZS
3PDT
LY3
LY3F
LY3S
--
--
--
4PDT
LY4
LY4F
LY4S
--
--
--
PCB
SPDT
LY1-0
--
--
--
--
--
DPDT
LY2-0
--
--
LY2Z-0
--
--
3PDT
LY3-0
--
--
--
--
--
4PDT
LY4-0
--
--
--
--
--
LED indicator
Plug-in/solder
SPDT
LY1N
--
--
--
--
--
DPDT
LY2N
--
--
LY2ZN
--
--
3PDT
LY3N
--
--
--
--
--
4PDT
LY4N
--
--
--
--
--
Diode surge
SPDT
LY1-D
--
--
--
--
--
suppression
DPDT
LY2-D
--
--
LY2Z-D
--
--
3PDT
LY3-D
--
--
--
--
--
4PDT
LY4-D
--
--
--
--
--
LED indicator
SPDT
LY1N-D2
--
--
--
--
--
and diode surge
DPDT
LY2N-D2
--
--
LY2ZN-D2
--
--
suppression
4PDT
LY4N-D2
--
--
--
--
--
RC circuit
SPDT
LY1-CR
--
--
--
--
--
DPDT
LY2-CR
--
--
LY2Z-CR
--
--
LED indicator
SPDT
LY1N-CR
--
--
--
--
--
and RC circuit
DPDT
LY2N-CR
--
--
LY2ZN-CR
--
--
Note:
1. Types with specifications other than those listed are available. Contact your OMRON Sales representative.
2. To order connecting sockets and mounting tracks, see "Accessories" section.
2
LY
LY
Solder
Wire wrap
terminal
terminal
Relay hold-down clip
Socket Mounting Plate
Relay
socket
socket
Standard
Push-to-test RC circuit
Mtg. plate
1
10
12
18
SPDT
PT08
PT08QN
PYC-P
PYC-P2
PYC-1
PYC-S
PYP-1
PYP-18
DPDT
3PDT
PT11
PT11QN
PTP-1-3
PTP-12
4PDT
PT14
PT14QN
PTP-1
PTP-10
Note:
1. Types with specifications other than those listed are available. Contact your OMRON Sales representative.
2. To order connecting sockets and mounting tracks, see "Accessories" section.
Ordering Information,
continued
Part number
Single contact
Bifurcated contact
Standard
Upper
Lower
Standard
Upper
Lower
Contact
bracket
mounting
mounting
bracket
mounting
mounting
Type
Terminal
form
mounting
bracket
bracket
mounting
bracket
bracket
Push-to-test
Plug-in/solder
SPDT
LY1l4
--
--
--
--
--
button
DPDT
LY2l4
--
--
LY2Zl2
--
--
3PDT
LY3l4
--
--
--
--
--
4PDT
LY4l4
--
--
--
--
--
LED indicator and
Plug-in/solder
DPDT
LY2l4N
--
--
LY2Zl2N
--
--
push-to-test button
4PDT
LY4l4N
--
--
--
--
--
s
ACCESSORIES
Connecting Sockets
To Order: Select the appropriate part numbers for sockets, clips, and mounting tracks (if required) from the following charts.
Track mounted sockets
Relay hold-down clip
Relay
Socket*
Standard
RC circuit
Mounting track
SPDT
PTF08A-E
PYC-A1
Y92H-3
PFP-100N/PFP-50N &
DPDT
PFP-M or PFP-100N2
3PDT
PTF11A
PFP-S (Option spacer)
4PDT
PTF14A-E
* Track mounted socket can be used as a front connecting socket.
Back connecting sockets
Note:
Types PYP-18, PTP-12 and PTP-10 may be cut to any desired length.
Relay hold-down clip
Relay
PC terminal socket
Standard
Push-to-test
RC circuit
SPDT
PT08-0
PYC-P
PYC-P2
PYC-1
DPDT
3PDT
PT11-0
4PDT
PT14-0
3
LY
LY
Coil inductance
Coil
(ref. value) (H)
Pick-up
Dropout
Maximum
Power
Rated
Rated current (mA)
resistance
Armature
Armature
voltage
voltage
voltage
consumption
voltage (V)
50 Hz
60 Hz
(
)
OFF
ON
(% of rated voltage)
(VA, W)
6
214.10
183
12.20
0.04
0.08
80% max.
30% min.
110%
Approx.
12
106.50
91
46
0.17
0.33
1.00 to 1.20
24
53.80
46
180
0.69
1.30
(60 Hz)
50
25.70
22
788
3.22
5.66
100/110
11.70/12.90
10/11
3,750
14.54
24.60
Approx.
110/120
9.90/10.80
8.40/9.20
4,430
19.20
32.10
0.90 to 1.10
200/220
6.20/6.80
5.30/5.80
12,950
54.75
94.07
(60 Hz)
220/240
4.80/5.30
4.20/4.60
18,790
83.50
136.40
Specifications
s
CONTACT DATA
Single contact
Bifurcated contact
SPDT
DPDT, 3PDT, 4PDT
DPDT
Resistive load
Inductive load
Resistive load
Inductive load
Resistive load
Inductive load
(p.f. = 1)
(p.f. = 0.4)
(p.f. = 1)
(p.f. = 0.4)
(p.f. = 1)
(p.f. = 0.4)
Load
(L/R = 7 ms)
(L/R = 7 ms)
(L/R = 7 ms)
Rated load
15 A at 110 VAC
10 A at 110 VAC
10 A at 110 VAC
7.5 A at 110 VAC 5 A at 110 VAC
4 A at 110 VAC
15 A at 24 VDC
7 A at 24 VDC
10 A at 24 VDC
5 A at 24 VDC
5 A at 24 VDC
4 A at 24 VDC
Contact material
AgCdO
Carry current
15 A
10 A
7 A
Max. operating
250 VAC
voltage
125 VDC
Max. operating
15 A
10 A
7 A
current
Max. switching
1,700 VA
1,100 VA
1,100 VA
830 VA
550 VA
440 VA
capacity
360 W
170 W
240 W
120 W
120 W
100 W
Min. permissible
100 mA, 5 VDC
10 mA, 5 VDC
load
s
COIL DATA
1- and 2-pole types AC
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
C (73
F) with tolerances of +15%, -20% for
AC rated current, and
15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23
C (73
F).
4. Class B coil insulation is available.
Coil inductance
Coil
(ref. value) (H)
Pick-up
Dropout
Maximum
Power
Rated
resistance
Armature
Armature
voltage
voltage
voltage
consumption
voltage (V)
Rated current (mA)
(
)
OFF
ON
(% of rated voltage)
(VA, W)
6
150
40
0.16
0.33
80% max.
10% min.
110%
Approx.
12
75
160
0.73
1.37
0.90
24
36.90
650
3.20
5.72
48
18.50
2,600
10.60
21
100/110
9.10/10
11,000
45.60
86.20
1- and 2-pole types DC
4
LY
LY
Coil inductance
Coil
(ref. value) (H)
Pick-up
Dropout
Maximum
Power
Rated
Rated current (mA)
resistance
Armature
Armature
voltage
voltage
voltage
consumption
voltage (V)
50 Hz
60 Hz
(
)
OFF
ON
(% of rated voltage)
(VA, W)
6
310
270
6.70
0.03
0.05
80% max.
30% min.
110%
Approx.
12
159
134
24
0.12
0.21
1.60 to 2.00
24
80
67
100
0.44
0.79
(60 Hz)
50
38
33
410
2.24
3.87
100/110
15.90/18.30
13.60/15.60
2,300
10.50
18.50
120
17.30
14.8
2,450
11.50
20.60
200/220
10.50/11.60 9.00/9.90
8,650
34.80
59.50
240
9.40
8
10,400
38.60
74.60
s
COIL DATA(continued)
3-pole type AC
3-pole type DC
Coil inductance
Coil
(ref. value) (H)
Pick-up
Dropout
Maximum
Power
Rated
resistance
Armature
Armature
voltage
voltage
voltage
consumption
voltage (V)
Rated current (mA)
(
)
OFF
ON
(% of rated voltage)
(VA, W)
6
234
25.70
0.11
0.21
80% max.
10% min.
110%
Approx.
12
112
107
0.45
0.98
1.40
24
58.60
410
1.89
3.87
48
28.20
1,700
8.53
13.90
100/110
12.70/13
8,500
29.60
54.30
Coil inductance
Coil
(ref. value) (H)
Pick-up
Dropout
Maximum
Power
Rated
Rated current (mA)
resistance
Armature
Armature
voltage
voltage
voltage
consumption
voltage (V)
50 Hz
60 Hz
(
)
OFF
ON
(% of rated voltage)
(VA, W)
6
386
330
5
0.02
0.04
80% max.
30% min.
110%
Approx.
12
199
170
20
0.10
0.17
1.95 to 2.50
24
93.60
80
78
0.38
0.67
(60 Hz)
50
46.80
40
350
1.74
2.88
100/110
22.50/25.50 19/21.80
1,800
10.50
17.30
120
19.00
16.40
2,200
9.30
19
200/220
11.50/13.10 9.80/11.20
6,700
33.10
57.90
240
11.00
9.50
9,000
33.20
63.40
4-pole type AC
4-pole type DC
Coil inductance
Coil
(ref. value) (H)
Pick-up
Dropout
Maximum
Power
Rated
resistance
Armature
Armature
voltage
voltage
voltage
consumption
voltage (V)
Rated current (mA)
(
)
OFF
ON
(% of rated voltage)
(VA, W)
6
240
25
0.09
0.21
80% max.
10% min.
110%
Approx.
12
120
100
0.39
0.84
1.50
24
69
350
1.41
2.91
48
30
1,600
6.39
13.60
100/110
15/15.90
6,900
32
63.70
Note:
1. The rated current and coil resistance are measured at a coil temperature of 23
C (73
F) with tolerances of +15%, -20% for
AC rated current, and
15% for DC rated coil resistance.
2. The AC coil resistance and inductance are reference values at 60 Hz.
3. The performance characteristics are measured at a coil temperature of 23
C (73
F).
4. Class B coil insulation is available.
5
LY
LY
s
CHARACTERISTICS
Contact resistance
50 m
max.
Operate time
25 ms max.
Release time
25 ms max.
Operating frequency
Mechanically
18,000 operations/hour
Under rated load
1,800 operations/hour
Insulation resistance
100 M
min. (at 500 VDC)
Dielectric strength
2,000 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
Vibration
Mechanical durability
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Malfunction durability
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
Shock
Mechanical durability
1,000 m/s
2
(approx. 100 G)
Malfunction durability
200 m/s
2
(approx. 20 G)
Ambient temperature
Operating
-40
to 70
C (-40
to 158
F)
Humidity
35 to 85% RH
Service Life
Mechanically
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
Electrically
See "Characteristic Data"
Weight
SPDT, DPDT: Approx. 40 g (1.41 oz), 3PDT: Approx. 50 g (1.76 oz)
4PDT: Approx. 70 g (2.47 oz)
Note:
Data shown are of initial value.
s
CHARACTERISTIC DATA
Maximum switching capacity
LY1
LY2
LY3, LY4
LY2Z
Electrical service life
LY1
LY2
LY3, LY4
LY2Z
Rated operating current (A)
Rated operating current (A)
Rated operating current (A)
Rated operating current (A)
Rated operating voltage (V)
Rated operating voltage (V)
Rated operating voltage (V)
Rated operating voltage (V)
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Service life (operations x 10
6
)
Rated operating current (A)
Rated operating current (A)
Rated operating current (A)
Rated operating current (A)