SC16C650A
Universal Asynchronous Receiver/Transmitter (UART)
with 32-byte FIFO and infrared (IrDA) encoder/decoder
Rev. 04 -- 20 June 2003
Product data
1.
General description
The SC16C650A is a Universal Asynchronous Receiver and Transmitter (UART)
used for serial data communications. Its principal function is to convert parallel data
into serial data, and vice versa. The UART can handle serial data rates up to
3 Mbits/s.
The SC16C650A is pin compatible with the ST16C650A and it will power-up to be
functionally equivalent to the 16C450. Programming of control registers enables the
added features of the SC16C650A. Some of these added features are the 32-byte
receive and transmit FIFOs, automatic hardware or software flow control and infrared
encoding/decoding. The selectable auto-flow control feature significantly reduces
software overload and increases system efficiency while in FIFO mode by
automatically controlling serial data flow using RTS output and CTS input signals.
The SC16C650A also provides DMA mode data transfers through FIFO trigger levels
and the RXRDY and TXRDY signals. On-board status registers provide the user with
error indications, operational status, and modem interface control. System interrupts
may be tailored to meet user requirements. An internal loop-back capability allows
on-board diagnostics.
The SC16C650A operates at 5 V, 3.3 V and 2.5 V, and the industrial temperature
range, and is available in plastic DIP40, PLCC44, and LQFP48 packages.
2.
Features
s
5 V, 3.3 V and 2.5 V operation
s
Industrial temperature range
s
After reset, all registers are identical to the typical 16C450 register set
s
Capable of running with all existing generic 16C450 software
s
Pin compatibility with the industry-standard ST16C450/550, TL16C450/550,
PC16C450/550
s
Up to 3 Mbits/s transmit/receive operation at 5 V, 2 Mbits/s at 3.3 V, and
1 Mbit/s at 2.5 V
s
32 byte transmit FIFO
s
32 byte receive FIFO with error flags
s
Programmable auto-RTS and auto-CTS
x
In auto-CTS mode, CTS controls transmitter
x
In auto-RTS mode, RxFIFO contents and threshold control RTS
s
Automatic software/hardware flow control
s
Programmable Xon/Xoff characters
s
Software selectable Baud Rate Generator
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
2 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
s
Four selectable Receive and Transmit FIFO interrupt trigger levels
s
Standard modem interface or infrared IrDA encoder/decoder interface
s
Sleep mode
s
Standard asynchronous error and framing bits (Start, Stop, and Parity Overrun
Break)
s
Independent receiver clock input
s
Transmit, Receive, Line Status, and Data Set interrupts independently controlled
s
Fully programmable character formatting:
x
5-, 6-, 7-, or 8-bit characters
x
Even-, Odd-, or No-Parity formats
x
1-, 1
1
/
2
-, or 2-stop bit
x
Baud generation (DC to 3 Mbit/s)
s
False start-bit detection
s
Complete status reporting capabilities
s
3-State output TTL drive capabilities for bi-directional data bus and control bus
s
Line Break generation and detection
s
Internal diagnostic capabilities:
x
Loop-back controls for communications link fault isolation
s
Prioritized interrupt system controls
s
Modem control functions (CTS, RTS, DSR, DTR, RI, DCD).
3.
Ordering information
Table 1:
Ordering information
Industrial: V
CC
= 2.5 V, 3.3 V or 5 V
10%; T
amb
=
-
40
C to +85
C.
Type number
Package
Name
Description
Version
SC16C650AIA44
PLCC44
plastic leaded chip carrier; 44 leads
SOT187-2
SC16C650AIB48
LQFP48
plastic low profile quad flat package; 48 leads; body 7
7
1.4 mm
SOT313-2
SC16C650AIN40
DIP40
plastic dual in-line package; 40 leads (600 mil)
SOT129-1
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
3 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
4.
Block diagram
Fig 1.
Block diagram.
TRANSMIT
FIFO
REGISTERS
TX
RECEIVE
SHIFT
REGISTER
RECEIVE
FIFO
REGISTERS
RX
INTERCONNECT B
US LINES
AND
CONTR
OL SIGNALS
SC16C650A
TRANSMIT
SHIFT
REGISTER
MODEM
CONTROL
LOGIC
DTR
RTS
CLOCK AND
BAUD RATE
GENERATOR
CTS
RI
DCD
DSR
XTAL2
BAUDOUT
XTAL1
RCLK
DATA BUS
AND
CONTROL LOGIC
D0D7
IOR, IOR
IOW, IOW
RESET
A0A2
CS0, CS1, CS2
REGISTER
SELECT
LOGIC
INT
TXRDY
RXRDY
INTERRUPT
CONTROL
LOGIC
002aaa295
FLOW
CONTROL
LOGIC
FLOW
CONTROL
LOGIC
IR
DECODER
IR
ENCODER
AS
OUT1, OUT2
DDIS
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
4 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
5.
Pinning information
5.1 Pinning
Fig 2.
PLCC44 pin configuration.
SC16C650AIA44
002aaa296
7
8
9
10
11
12
13
14
15
16
17
39
38
37
36
35
34
33
32
31
30
29
18
19
20
21
22
23
24
25
26
27
28
6
5
4
3
2
1
44
43
42
41
40
D4
D3
D2
D1
D0
NC
V
CC
RI
DCD
DSR
CTS
XTAL1
XTAL2
IOW
IOW
GND
NC
IOR
IOR
DDIS
TXRDY
AS
D5
D6
D7
RCLK
RX
NC
TX
CS0
CS1
CS2
BAUDOUT
RESET
OUT1
DTR
RTS
OUT2
NC
INT
RXRDY
A0
A1
A2
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
5 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 3.
LQFP48 pin configuration.
SC16C650AIB48
002aaa298
1
2
3
4
5
6
7
8
9
10
11
12
36
35
34
33
32
31
30
29
28
27
26
25
13
14
15
16
17
18
19
20
21
22
23
24
48
47
46
45
44
43
42
41
40
39
38
37
NC
D4
D3
D2
D1
D0
V
CC
RI
DCD
DSR
CTS
NC
NC
XTAL1
XTAL2
IOW
IOW
GND
IOR
IOR
NC
DDIS
TXRDY
AS
NC
D5
D6
D7
RCLK
NC
RX
TX
CS0
CS1
CS2
BAUDOUT
NC
RESET
OUT1
DTR
RTS
OUT2
INT
RXRDY
A0
A1
A2
NC
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
6 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
5.2 Pin description
Fig 4.
DIP40 pin configuration.
SC16C650AIN40
002aaa299
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
D0
D1
D2
D3
D4
D5
D6
D7
RCLK
RX
TX
CS0
CS1
BAUDOUT
XTAL1
XTAL2
IOW
IOW
GND
VCC
RI
DCD
DSR
CTS
RESET
OUT1
DTR
RTS
OUT2
INT
RXRDY
A0
A1
A2
AS
TXRDY
DDIS
IOR
IOR
40
39
38
37
36
35
34
33
32
31
30
29
28
27
26
25
24
23
22
21
CS2
Table 2:
Pin description
Symbol
Pin
Type
Description
PLCC44 LQFP48 DIP40
A0-A2
28, 27,
26
28, 27,
26
28, 27,
26
I
Register select. A0-A2 are used during read and write operations to
select the UART register to read from or write to. Refer to
Table 3
for
register addresses and refer to AS description.
AS
28
24
25
I
Address strobe. When AS is active (LOW), A0, A1, and A2 and CS0,
CS1, and CS2 drive the internal select logic directly; when AS is
HIGH, the register select and chip select signals are held at the logic
levels they were in when the LOW-to-HIGH transition of AS occurred.
BAUDOUT
17
12
15
O
Baud out. BAUDOUT is a 16
clock signal for the transmitter section
of the UART. The clock rate is established by the reference oscillator
frequency divided by a divisor specified in the baud generator divisor
latches. BAUDOUT may also be used for the receiver section by tying
this output to RCLK.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
7 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
CS0, CS1,
CS2
14, 15,
16
9, 10,
11
12, 13,
14
I
Chip select. When CS0 and CS1 are HIGH and CS2 is LOW, these
three inputs select the UART. When any of these inputs are inactive,
the UART remains inactive (refer to AS description).
CTS
40
38
36
I
Clear to send. CTS is a modem status signal. Its condition can be
checked by reading bit 4 (CTS) of the modem status register. Bit 0
(
CTS) of the modem status register indicates that CTS has changed
states since the last read from the modem status register. If the
modem status interrupt is enabled when CTS changes levels and the
auto-CTS mode is not enabled, an interrupt is generated. CTS is also
used in the auto-CTS mode to control the transmitter.
D(7:0)
2-9
43-47,
2-4
8-1
I/O
Data bus. Eight data lines with 3-State outputs provide a bi-directional
path for data, control and status information between the UART and
the CPU.
DCD
42
40
38
I
Data carrier detect. DCD is a modem status signal. Its condition can
be checked by reading bit 7 (DCD) of the modem status register. Bit 3
(
DCD) of the modem status register indicates that DCD has changed
states since the last read from the modem status register. If the
modem status interrupt is enabled when DCD changes levels, an
interrupt is generated.
DDIS
26
22
23
O
Driver disable. DDIS is active (LOW) when the CPU is not reading
data. When active, DDIS can disable an external transceiver.
DSR
41
39
37
I
Data set ready. DSR is a modem status signal. Its condition can be
checked by reading bit 5 (DSR) of the modem status register. Bit 1
(
DSR) of the modem status register indicates DSR has changed
levels since the last read from the modem status register. If the
modem status interrupt is enabled when DSR changes levels, an
interrupt is generated.
DTR
37
33
33
O
Data terminal ready. When active (LOW), DTR informs a modem or
data set that the UART is ready to establish communication. DTR is
placed in the active level by setting the DTR bit of the modem control
register. DTR is placed in the inactive level either as a result of a
Master Reset, during loop mode operation, or clearing the DTR bit.
INT
33
30
30
O
Interrupt. When active (HIGH), INT informs the CPU that the UART
has an interrupt to be serviced. Four conditions that cause an interrupt
to be issued are: a receiver error, received data that is available or
timed out (FIFO mode only), an empty transmitter holding register or
an enabled modem status interrupt. INT is reset (deactivated) either
when the interrupt is serviced or as a result of a Master Reset.
MR
39
35
35
I
Master Reset. When active (HIGH), MR clears most UART registers
and sets the levels of various output signals.
OUT1, OUT2 38, 35
34, 31
34, 31
O
Outputs 1 and 2. These are user-designated output terminals that are
set to the active (low) level by setting respective modem control
register (MCR) bits (OUT1 and OUT2). OUT1 and OUT2 are set to
inactive the (HIGH) level as a result of Master Reset, during loop mode
operations, or by clearing bit 2 (OUT1) or bit 3 (OUT2) of the MCR.
RCLK
10
5
9
I
Receiver clock. RCLK is the 16
baud rate clock for the receiver
section of the UART.
Table 2:
Pin description
...continued
Symbol
Pin
Type
Description
PLCC44 LQFP48 DIP40
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
8 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
IOR, IOR
24, 25
19, 20
21, 22
I
Read inputs. When either IOR or IOR is active (LOW or HIGH,
respectively) while the UART is selected, the CPU is allowed to read
status information or data from a selected UART register. Only one of
these inputs is required for the transfer of data during a read operation;
the other input should be tied to its inactive level (i.e., IOR tied LOW or
IOR tied HIGH).
RI
43
41
39
I
Ring indicator. RI is a modem status signal. Its condition can be
checked by reading bit 6 (RI) of the modem status register. Bit 2 (
RI)
of the modem status register indicates that RI has transitioned from a
LOW to a HIGH level since the last read from the modem status
register. If the modem status interrupt is enabled when this transition
occurs, an interrupt is generated.
RTS
36
32
32
O
Request to send. When active, RTS informs the modem or data set
that the UART is ready to receive data. RTS is set to the active level by
setting the RTS modem control register bit and is set to the inactive
(HIGH) level either as a result of a Master Reset or during loop mode
operations or by clearing bit 1 (RTS) of the MCR. In the auto-RTS
mode, RTS is set to the inactive level by the receiver threshold control
logic.
RXRDY
32
29
29
O
Receiver ready. Receiver direct memory access (DMA) signaling is
available with RXRDY. When operating in the FIFO mode, one of two
types of DMA signaling can be selected using the FIFO control register
bit 3 (FCR[3]). When operating in the 16C450 mode, only DMA mode
0 is allowed. Mode 0 supports single-transfer DMA in which a transfer
is made between CPU bus cycles. Mode 1 supports multi-transfer
DMA in which multiple transfers are made continuously until the
receiver FIFO has been emptied. In DMA mode 0 (FCR0 = 0 or
FCR0 = 1, FCR3 = 0), when there is at least one character in the
receiver FIFO or receiver holding register, RXRDY is active (LOW).
When RXRDY has been active but there are no characters in the FIFO
or holding register, RXRDY goes inactive (HIGH). In DMA mode 1
(FCR0 = 1, FCR3 = 1), when the trigger level or the time-out has been
reached, RXRDY goes active (LOW); when it has been active but there
are no more characters in the FIFO or holding register, it goes inactive
(HIGH).
RX
11
7
10
I
Serial data input. RX is serial data input from a connected
communications device.
TX
13
8
11
I
Serial data output. TX is composite serial data output to a connected
communication device. TX is set to the marking (HIGH) level as a
result of Master Reset.
TXRDY
27
23
24
O
Transmitter ready. Transmitter DMA signaling is available with
TXRDY. When operating in the FIFO mode, one of two types of DMA
signaling can be selected using FCR[3]. When operating in the
16C450 mode, only DMA mode 0 is allowed. Mode 0 supports
single-transfer DMA in which a transfer is made between CPU bus
cycles. Mode 1 supports multi-transfer DMA in which multiple transfers
are made continuously until the transmit FIFO has been filled.
V
CC
44
42
40
Power 2.5 V, 3 V or 5 V supply voltage.
V
SS
22
18
20
Power Ground voltage.
Table 2:
Pin description
...continued
Symbol
Pin
Type
Description
PLCC44 LQFP48 DIP40
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
9 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
[1]
In sleep mode, XTAL2 is left floating.
6.
Functional description
The SC16C650A provides serial asynchronous receive data synchronization,
parallel-to-serial and serial-to-parallel data conversions for both the transmitter and
receiver sections. These functions are necessary for converting the serial data
stream into parallel data that is required with digital data systems. Synchronization for
the serial data stream is accomplished by adding start and stop bits to the transmit
data to form a data character (character orientated protocol). Data integrity is insured
by attaching a parity bit to the data character. The parity bit is checked by the receiver
for any transmission bit errors. The SC16C650A is fabricated with an advanced
CMOS process to achieve low drain power and high speed requirements.
The SC16C650A is an upward solution that provides 32 bytes of transmit and receive
FIFO memory, instead of none in the 16C450, or 16 in the 16C550. The SC16C650A
is designed to work with high speed modems and shared network environments that
require fast data processing time. Increased performance is realized in the
SC16C650A by the larger transmit and receive FIFOs. This allows the external
processor to handle more networking tasks within a given time. In addition, the four
selectable levels of FIFO trigger interrupt and automatic hardware/software flow
control is uniquely provided for maximum data throughput performance, especially
when operating in a multi-channel environment. The combination of the above greatly
reduces the bandwidth requirement of the external controlling CPU, increases
performance, and reduces power consumption.
The SC16C650A is capable of operation up to 3 Mbits/s with a 48 MHz external clock
input (at 5 V).
The rich feature set of the SC16C650A is available through internal registers.
Automatic hardware/software flow control, selectable transmit and receive FIFO
trigger level, selectable TX and RX baud rates, modem interface controls, and a sleep
mode are some of these features.
IOW, IOW
20, 21
16, 17
18, 19
I
Write inputs. When either IOW or IOW is active (LOW or HIGH,
respectively) and while the UART is selected, the CPU is allowed to
write control words or data into a selected UART register. Only one of
these inputs is required to transfer data during a write operation; the
other input should be tied to its inactive level (i.e., IOW tied LOW or
IOW tied HIGH).
XTAL1
18
14
16
I
Crystal connection or External clock input.
XTAL2
[1]
19
15
17
O
Crystal connection or the inversion of XTAL1 if XTAL1 is driven.
Table 2:
Pin description
...continued
Symbol
Pin
Type
Description
PLCC44 LQFP48 DIP40
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
10 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
6.1 Internal registers
The SC16C650A provides 15 internal registers for monitoring and control. These
registers are shown in
Table 3
. Twelve registers are similar to those already available
in the standard 16C550. These registers function as data holding registers
(THR/RHR), interrupt status and control registers (IER/ISR), a FIFO control register
(FCR), line status and control registers (LCR/LSR), modem status and control
registers (MCR/MSR), programmable data rate (clock) control registers (DLL/DLM),
and a user accessible scratchpad register (SPR). Beyond the general 16C550
features and capabilities, the SC16C650A offers an enhanced feature register set
(EFR, Xon/Xoff1-2) that provides on-board hardware/software flow control. Register
functions are more fully described in the following paragraphs.
[1]
These registers are accessible only when LCR[7] is a logic 0.
[2]
These registers are accessible only when LCR[7] is a logic 1.
[3]
Enhanced Feature Register, Xon1, 2 and Xoff1, 2 are accessible only when the LCR is set to "BF"
(HEX).
6.2 FIFO operation
The 32-byte transmit and receive data FIFOs are enabled by the FIFO Control
Register bit-0 (FCR[0]). With 16C550 devices, the user can set the receive trigger
level, but not the transmit trigger level. The SC16C650A provides independent trigger
levels for both receiver and transmitter. To remain compatible with SC16C550, the
transmit interrupt trigger level is set to 16 following a reset. It should be noted that the
user can set the transmit trigger levels by writing to the FCR register, but activation
will not take place until EFR[4] is set to a logic 1. The receiver FIFO section includes
Table 3:
Internal registers decoding
A2
A1
A0
READ mode
WRITE mode
General register set (THR/RHR, IER/ISR, MCR/MSR, FCR, LSR, SPR)
[1]
0
0
0
Receive Holding Register
Transmit Holding Register
0
0
1
Interrupt Enable Register
0
1
0
Interrupt Status Register
FIFO Control Register
0
1
1
Line Control Register
1
0
0
Modem Control Register
1
0
1
Line Status Register
n/a
1
1
0
Modem Status Register
n/a
1
1
1
Scratchpad Register
Scratchpad Register
Baud rate register set (DLL/DLM)
[2]
0
0
0
LSB of Divisor Latch
LSB of Divisor Latch
0
0
1
MSB of Divisor Latch
MSB of Divisor Latch
Enhanced register set (EFR, Xon/off 1-2)
[3]
0
1
0
Enhanced Feature Register
Enhanced Feature Register
1
0
0
Xon1 word
Xon1 word
1
0
1
Xon2 word
Xon2 word
1
1
0
Xoff1 word
Xoff1 word
1
1
1
Xoff2 word
Xoff2 word
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
11 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
a time-out function to ensure data is delivered to the external CPU. An interrupt is
generated whenever the Receive Holding Register (RHR) has not been read
following the loading of a character or the receive trigger level has not been reached.
6.3 Hardware flow control
When automatic hardware flow control is enabled, the SC16C650A monitors the CTS
pin for a remote buffer overflow indication and controls the RTS pin for local buffer
overflows. Automatic hardware flow control is selected by setting EFR[6] (RTS) and
EFR[7] (CTS) to a logic 1. If CTS transitions from a logic 0 to a logic 1 indicating a
flow control request, ISR[5] will be set to a logic 1 (if enabled via IER[6,7]), and the
SC16C650A will suspend TX transmissions as soon as the stop bit of the character in
process is shifted out. Transmission is resumed after the CTS input returns to a
logic 0, indicating more data may be sent.
With the Auto-RTS function enabled, an interrupt is generated when the receive FIFO
reaches the programmed trigger level. The RTS pin will not be forced to a logic 1
(RTS off), until the receive FIFO reaches the next trigger level. However, the RTS pin
will return to a logic 0 after the data buffer (FIFO) is unloaded to the next trigger level
below the programmed trigger level. However, under the above described conditions,
the SC16C650A will continue to accept data until the receive FIFO is full.
6.4 Software flow control
When software flow control is enabled, the SC16C650A compares one or two
sequential receive data characters with the programmed Xon or Xoff character
value(s). If received character(s) match the programmed Xoff values, the
SC16C650A will halt transmission (TX) as soon as the current character(s) has
completed transmission. When a match occurs, the receive ready (if enabled via Xoff
IER[5]) flags will be set and the interrupt output pin (if receive interrupt is enabled) will
be activated. Following a suspension due to a match of the Xoff characters' values,
the SC16C650A will monitor the receive data stream for a match to the Xon1,2
character value(s). If a match is found, the SC16C650A will resume operation and
clear the flags (ISR[4]).
Reset initially sets the contents of the Xon/Xoff 8-bit flow control registers to a logic 0.
Following reset, the user can write any Xon/Xoff value desired for software flow
control. Different conditions can be set to detect Xon/Xoff characters and
suspend/resume transmissions. When double 8-bit Xon/Xoff characters are selected,
the SC16C650A compares two consecutive receive characters with two software flow
control 8-bit values (Xon1, Xon2, Xoff1, Xoff2) and controls TX transmissions
accordingly. Under the above described flow control mechanisms, flow control
Table 4:
Flow control mechanism
Selected trigger level
(characters)
INT pin activation
Negate RTS or
send Xoff
Assert RTS or
send Xon
8
8
16
0
16
16
24
7
24
24
28
15
28
28
28
23
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
12 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
characters are not placed (stacked) in the user accessible RX data buffer or FIFO.
When using a software flow control the Xon/Xoff characters cannot be used for data
transfer.
In the event that the receive buffer is overfilling and flow control needs to be executed,
the SC16C650A automatically sends an Xoff message (when enabled) via the serial
TX output to the remote modem. The SC16C650A sends the Xoff1,2 characters as
soon as received data passes the programmed trigger level. To clear this condition,
the SC16C650A will transmit the programmed Xon1,2 characters as soon as receive
data drops below the programmed trigger level.
6.5 Special feature software flow control
A special feature is provided to detect an 8-bit character when EFR[5] is set. When
8-bit character is detected, it will be placed on the user-accessible data stack along
with normal incoming RX data. This condition is selected in conjunction with
EFR[0-3]. Note that software flow control should be turned off when using this special
mode by setting EFR[0-3] to a logic 0.
The SC16C650A compares each incoming receive character with Xoff2 data. If a
match exists, the received data will be transferred to the FIFO, and ISR[4] will be set
to indicate detection of a special character. Although the Internal Register Table
(
Table 8
) shows each X-Register with eight bits of character information, the actual
number of bits is dependent on the programmed word length. Line Control Register
bits LCR[0-1] define the number of character bits, i.e., either 5 bits, 6 bits, 7 bits or
8 bits. The word length selected by LCR[0-1] also determine the number of bits that
will be used for the special character comparison. Bit 0 in the X-registers corresponds
with the LSB bit for the receive character.
6.6 Hardware/software and time-out interrupts
Three special interrupts have been added to monitor the hardware and software flow
control. The interrupts are enabled by IER[5-7]. Care must be taken when handling
these interrupts. Following a reset, the transmitter interrupt is enabled, the
SC16C650A will issue an interrupt to indicate that the Transmit Holding Register is
empty. This interrupt must be serviced prior to continuing operations. The LSR
register provides the current singular highest priority interrupt only. It could be noted
that CTS and RTS interrupts have lowest interrupt priority. A condition can exist
where a higher priority interrupt may mask the lower priority CTS/RTS interrupt(s).
Only after servicing the higher pending interrupt will the lower priority CTS/TRS
interrupt(s) be reflected in the status register. Servicing the interrupt without
investigating further interrupt conditions can result in data errors.
When two interrupt conditions have the same priority, it is important to service these
interrupts correctly. Receive Data Ready and Receive Time Out have the same
interrupt priority (when enabled by IER[0]). The receiver issues an interrupt after the
number of characters have reached the programmed trigger level. In this case, the
SC16C650A FIFO may hold more characters than the programmed trigger level.
Following the removal of a data byte, the user should re-check LSR[0] for additional
characters. A Receive Time Out will not occur if the receive FIFO is empty. The
time-out counter is reset at the center of each stop bit received or each time the
receive holding register (RHR) is read. The actual time-out value is 4 character time.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
13 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
6.7 Programmable baud rate generator
The SC16C650A supports high speed modem technologies that have increased
input data rates by employing data compression schemes. For example, a 33.6 kbit/s
modem that employs data compression may require a 115.2 kbit/s input data rate.
A 128.0 kbit/s ISDN modem that supports data compression may need an input
data rate of 460.8 kbit/s.
A single baud rate generator is provided for the transmitter and receiver, allowing
independent TX/RX channel control. The programmable Baud Rate Generator is
capable of accepting an input clock up to 48 MHz, as required for supporting a
3 Mbits/s data rate. The SC16C650A can be configured for internal or external clock
operation. For internal clock oscillator operation, an industry standard microprocessor
crystal (parallel resonant/22-33 pF load) is connected externally between the XTAL1
and XTAL2 pins (see
Figure 5
). Alternatively, an external clock can be connected to
the XTAL1 pin to clock the internal baud rate generator for standard or custom rates
(see
Table 5
).
The generator divides the input 16
clock by any divisor from 1 to 2
16
-
1. The
SC16C650A divides the basic crystal or external clock by 16. The frequency of the
BAUDOUT output pin is exactly 16
(16 times) of the selected baud rate
(BAUDOUT = 16 Baud Rate). Customized baud rates can be achieved by selecting
the proper divisor values for the MSB and LSB sections of baud rate generator.
Setting MCR[7] to a logic 1 provides an additional divide-by-4, whereas setting
MCR[7] to a logic 0 only divides by 1 (see
Table 5
and
Figure 6
).
Programming the Baud Rate Generator registers DLM (MSB) and DLL (LSB)
provides a user capability for selecting the desired final baud rate. The example in
Table 5
shows selectable baud rates when using a 1.8432 MHz crystal and setting
MCR[7] to a logic 0.
For custom baud rates, the divisor value can be calculated using the following
equation:
(1)
Fig 5.
Crystal oscillator connection.
002aaa169
X1
1.8432 MHz
C1
22 pF
C2
47 pF
XT
AL1
XT
AL2
X1
1.8432 MHz
C1
47 pF
C2
100 pF
XT
AL1
XT
AL2
1.5 k
Divisor (in decimal)
XTAL1 clock frequency
serial data rate
16
-----------------------------------------------------------
=
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
14 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Table 5:
Baud rates using 1.8432 MHz or 3.072 MHz crystal
Using 1.8432 MHz crystal
Using 3.072 MHz crystal
Desired
baud rate
Divisor for
16
clock
Baud rate
error
Desired
baud rate
Divisor for
16
clock
Baud rate
error
50
2304
50
3840
75
1536
75
2560
110
1047
0.026
110
1745
0.026
134.5
857
0.058
134.5
1428
0.034
150
768
150
1280
300
384
300
640
600
192
600
320
1200
96
1200
160
1800
64
1800
107
0.312
2000
58
0.69
2000
96
2400
48
2400
80
3600
32
3600
53
0.628
4800
24
4800
40
7200
16
7200
27
1.23
9600
12
9600
20
19200
6
19200
10
38400
3
38400
5
56000
2
2.86
Fig 6.
Baud rate generator circuitry.
BAUD RATE
GENERATOR
LOGIC
BAUDOUT
MCR[7] = 1
MCR[7] = 0
DIVIDE-BY-1
LOGIC
DIVIDE-BY-4
LOGIC
CLOCK
OSCILLATOR
LOGIC
002aaa208
XTAL1
XTAL2
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
15 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
6.8 DMA operation
The SC16C650A FIFO trigger level provides additional flexibility to the user for block
mode operation. The user can optionally operate the transmit and receive FIFOs in
the DMA mode (FCR[3]). The DMA mode affects the state of the RXRDY and TXRDY
output pins. Tables
6
and
7
show this.
6.9 Sleep mode
The SC16C650A is designed to operate with low power consumption. A special sleep
mode is included to further reduce power consumption when the chip is not being
used. With EFR[4] and IER[4] enabled (set to a logic 1), the SC16C650A enters the
sleep mode, but resumes normal operation when a start bit is detected, a change of
state on any of the modem input pins RX, RI, CTS, DSR, DCD, or a transmit data is
provided by the user. If the sleep mode is enabled and the SC16C650A is awakened
by one of the conditions described above, it will return to the sleep mode
automatically after the last character is transmitted or read by the user. In any case,
the sleep mode will not be entered while an interrupt(s) is pending. The SC16C650A
will stay in the sleep mode of operation until it is disabled by setting IER[4] to a
logic 0.
6.10 Loop-back mode
The internal loop-back capability allows on-board diagnostics. In the loop-back mode,
the normal modem interface pins are disconnected and reconfigured for loop-back
internally. MCR[0-3] register bits are used for controlling loop-back diagnostic testing.
In the loop-back mode, OUT1 and OUT2 in the MCR register (bits 2-3) control the
modem RI and DCD inputs, respectively. MCR signals DTR and RTS (bits 0-1) are
used to control the modem CTS and DSR inputs, respectively. The transmitter output
(TX) and the receiver input (RX) are disconnected from their associated interface
pins, and instead are connected together internally (see
Figure 7
). The CTS, DSR,
DCD, and RI are disconnected from their normal modem control input pins, and
instead are connected internally to DTR, RTS, OUT1 and OUT2. Loop-back test data
is entered into the transmit holding register via the user data bus interface, D0-D7.
The transmit UART serializes the data and passes the serial data to the receive
UART via the internal loop-back connection. The receive UART converts the serial
data back into parallel data that is then made available at the user data interface
D0-D7. The user optionally compares the received data to the initial transmitted data
for verifying error-free operation of the UART TX/RX circuits.
Table 6:
Effect of DMA mode on state of RXRDY pin
Non-DMA mode
DMA mode
1 = FIFO empty
0-to-1 transition when FIFO empties
0 = at least 1 byte in FIFO
1-to-0 transition when FIFO reaches trigger level,
or time-out occurs
Table 7:
Effect of DMA mode on state of TXRDY pin
Non-DMA mode
DMA mode
1 = at least 1 byte in FIFO
0-to-1 transition when FIFO becomes full
0 = FIFO empty
1-to-0 transition when FIFO goes below trigger level
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
16 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
In this mode, the receiver and transmitter interrupts are fully operational. The Modem
Control Interrupts are also operational. However, the interrupts can only be read
using lower four bits of the Modem Status Register (MSR[0-3]) instead of the four
Modem Status Register bits 4-7. The interrupts are still controlled by the IER.
Fig 7.
Internal loop-back mode diagram.
TRANSMIT
FIFO
REGISTERS
TX
RECEIVE
SHIFT
REGISTER
RECEIVE
FIFO
REGISTERS
RX
INTERCONNECT
B
US LINES
AND
CONTR
OL SIGNALS
SC16C650A
TRANSMIT
SHIFT
REGISTER
MODEM
CONTROL
LOGIC
CLOCK AND
BAUD RATE
GENERATOR
XTAL2
XTAL1
DATA BUS
AND
CONTROL LOGIC
D0D7
IOR, IOR
IOW, IOW
RESET
A0A2
CS0, CS1
REGISTER
SELECT
LOGIC
INT
TXRDY
RXRDY
INTERRUPT
CONTROL
LOGIC
002aaa303
MCR[4] = 1
DSR
RTS
DTR
CTS
OUT1
OUT2
DCD
RI
FLOW
CONTROL
LOGIC
FLOW
CONTROL
LOGIC
IR
ENCODER
IR
DECODER
CS2
AS
DDIS
RCLK
BAUDOUT
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
17 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.
Register descriptions
Table 8
details the assigned bit functions for the fifteen SC16C650A internal registers.
The assigned bit functions are more fully defined in
Section 7.1
through
Section 7.11
.
[1]
The value shown represents the register's initialized HEX value; X = n/a.
[2]
These registers are accessible only when LCR[7] = 0.
[3]
The Special Register set is accessible only when LCR[7] is set to a logic 1.
[4]
Enhanced Feature Register, Xon-1,2 and Xoff-1,2 are accessible only when LCR is set to `BF
Hex
'.
Table 8:
SC16C650A internal registers
Shaded bits are only accessible when EFR[4] is set.
A2
A1
A0
Register Default
[1]
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
General Register Set
[2]
0
0
0
RHR
XX
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
0
0
0
THR
XX
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
0
0
1
IER
00
CTS
interrupt
RTS
interrupt
Xoff
interrupt
Sleep
mode
modem
status
interrupt
receive
line status
interrupt
transmit
holding
register
receive
holding
register
0
1
0
FCR
00
RCVR
trigger
(MSB)
RCVR
trigger
(LSB)
TX
trigger
(MSB)
TX trigger
(LSB)
DMA
mode
select
XMIT
FIFO
reset
RCVR
FIFO
reset
FIFO
enable
0
1
0
ISR
01
FIFOs
enabled
FIFOs
enabled
INT
priority
bit 4
INT
priority
bit 3
INT
priority
bit 2
INT
priority
bit 1
INT
priority
bit 0
INT
status
0
1
1
LCR
00
divisor
latch
enable
set break set parity even
parity
parity
enable
stop bits
word
length
bit 1
word
length
bit 0
1
0
0
MCR
00
Clock
select
IR enable INT type
select
loop back OUT2,
INT
enable
OUT1
RTS
DTR
1
0
1
LSR
60
FIFO
data
error
trans.
empty
trans.
holding
empty
break
interrupt
framing
error
parity
error
overrun
error
receive
data
ready
1
1
0
MSR
X0
DCD
RI
DSR
CTS
DCD
RI
DSR
CTS
1
1
1
SPR
FF
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Special Register Set
[3]
0
0
0
DLL
XX
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
0
0
1
DLM
XX
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
Enhanced Register Set
[4]
0
1
0
EFR
00
Auto
CTS
Auto RTS Special
char.
select
Enable
IER[4-7],
ISR[4,5],
FCR[4,5],
MCR[5-7]
Cont-3
Tx, Rx
Control
Cont-2
Tx, Rx
Control
Cont-1
Tx, Rx
Control
Cont-0
Tx, Rx
Control
1
0
0
Xon-1
00
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
1
0
1
Xon-2
00
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
1
1
0
Xoff-1
00
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
1
1
1
Xoff-2
00
bit 15
bit 14
bit 13
bit 12
bit 11
bit 10
bit 9
bit 8
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
18 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.1 Transmit (THR) and Receive (RHR) Holding Registers
The serial transmitter section consists of an 8-bit Transmit Hold Register (THR) and
Transmit Shift Register (TSR). The status of the THR is provided in the Line Status
Register (LSR). Writing to the THR transfers the contents of the data bus (D7-D0) to
the THR, providing that the THR or TSR is empty. The THR empty flag in the LSR
register will be set to a logic 1 when the transmitter is empty or when data is
transferred to the TSR. Note that a write operation can be performed when the THR
empty flag is set (logic 0 = FIFO full; logic 1 = at least one FIFO location available).
The serial receive section also contains an 8-bit Receive Holding Register (RHR).
Receive data is removed from the SC16C650A and receive FIFO by reading the RHR
register. The receive section provides a mechanism to prevent false starts. On the
falling edge of a start or false start bit, an internal receiver counter starts counting
clocks at the 16
clock rate. After 7-
1
/
2
clocks, the start bit time should be shifted to
the center of the start bit. At this time the start bit is sampled, and if it is still a logic 0
it is validated. Evaluating the start bit in this manner prevents the receiver from
assembling a false character. Receiver status codes will be posted in the LSR.
7.2 Interrupt Enable Register (IER)
The Interrupt Enable Register (IER) masks the interrupts from receiver ready,
transmitter empty, line status and modem status registers. These interrupts would
normally be seen on the INT output pin.
Table 9:
Interrupt Enable Register bits description
Bit
Symbol
Description
7
IER[7]
CTS interrupt.
Logic 0 = Disable the CTS interrupt (normal default condition).
Logic 1 = Enable the CTS interrupt. The SC16C650A issues an interrupt
when the CTS pin transitions from a logic 0 to a logic 1.
6
IER[6]
RTS interrupt.
Logic 0 = Disable the RTS interrupt (normal default condition).
Logic 1 = Enable the RTS interrupt. The SC16C650A issues an interrupt
when the RTS pin transitions from a logic 0 to a logic 1.
5
IER[5]
Xoff interrupt.
Logic 0 = Disable the software flow control, receive Xoff interrupt
(normal default condition).
Logic 1 = Enable the software flow control, receive Xoff interrupt. See
Section 6.4 "Software flow control"
for details.
4
IER[4]
Sleep mode.
Logic 0 = Disable sleep mode (normal default condition).
Logic 1 = Enable sleep mode. See
Section 6.9 "Sleep mode"
for details.
3
IER[3]
Modem Status Interrupt.
Logic 0 = Disable the modem status register interrupt (normal default
condition).
Logic 1 = Enable the modem status register interrupt.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
19 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.2.1
IER versus Receive FIFO interrupt mode operation
When the receive FIFO (FCR[0] = logic 1), and receive interrupts (IER[0] = logic 1)
are enabled, the receive interrupts and register status will reflect the following:
The receive data available interrupts are issued to the external CPU when the
FIFO has reached the programmed trigger level. It will be cleared when the FIFO
drops below the programmed trigger level.
FIFO status will also be reflected in the user accessible ISR register when the
FIFO trigger level is reached. Both the ISR register status bit and the interrupt will
be cleared when the FIFO drops below the trigger level.
The data ready bit (LSR[0]) is set as soon as a character is transferred from the
shift register to the receive FIFO. It is reset when the FIFO is empty.
7.2.2
IER versus Receive/Transmit FIFO polled mode operation
When FCR[0] = logic 1, resetting IER[0-3] enables the SC16C650A in the FIFO
polled mode of operation. Since the receiver and transmitter have separate bits in the
LSR, either or both can be used in the polled mode by selecting respective transmit or
receive control bit(s).
LSR[0] will be a logic 1 as long as there is one byte in the receive FIFO.
LSR[1-4] will provide the type of errors encountered, if any.
LSR[5] will indicate when the transmit FIFO is empty.
LSR[6] will indicate when both the transmit FIFO and transmit shift register are
empty.
LSR[7] will indicate any FIFO data errors.
2
IER[2]
Receive Line Status interrupt. This interrupt will be issued whenever a fully
assembled receive character is transferred from RSR to the RHR/FIFO,
i.e., data ready, LSR[0].
Logic 0 = Disable the receiver line status interrupt (normal default
condition).
Logic 1 = Enable the receiver line status interrupt.
1
IER[1]
Transmit Holding Register interrupt. This interrupt will be issued whenever
the THR is empty, and is associated with LSR[1].
Logic 0 = Disable the transmitter empty interrupt (normal default
condition).
Logic 1 = Enable the transmitter empty interrupt.
0
IER[0]
Receive Holding Register interrupt. This interrupt will be issued when the
FIFO has reached the programmed trigger level, or is cleared when the
FIFO drops below the trigger level in the FIFO mode of operation.
Logic 0 = Disable the receiver ready interrupt (normal default condition).
Logic 1 = Enable the receiver ready interrupt.
Table 9:
Interrupt Enable Register bits description
...continued
Bit
Symbol
Description
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
20 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.3 FIFO Control Register (FCR)
This register is used to enable the FIFOs, clear the FIFOs, set the receive FIFO
trigger levels, and select the DMA mode.
7.3.1
DMA mode
Mode 0 (FCR bit 3 = 0):
Set and enable the interrupt for each single transmit or
receive operation, and is similar to the 16C450 mode. Transmit Ready (TXRDY) will
go to a logic 0 whenever an empty transmit space is available in the Transmit Holding
Register (THR). Receive Ready (RXRDY) will go to a logic 0 whenever the Receive
Holding Register (RHR) is loaded with a character.
Mode 1 (FCR bit 3 = 1):
Set and enable the interrupt in a block mode operation. The
transmit interrupt is set when the transmit FIFO is below the programmed trigger
level. The receive interrupt is set when the receive FIFO fills to the programmed
trigger level. However, the FIFO continues to fill regardless of the programmed level
until the FIFO is full. RXRDY remains a logic 0 as long as the FIFO fill level is above
the programmed trigger level.
7.3.2
FIFO mode
Table 10:
FIFO Control Register bits description
Bit
Symbol
Description
7-6
FCR[7]
(MSB),
FCR[6]
(LSB)
RCVR trigger. These bits are used to set the trigger level for the receive
FIFO interrupt.
An interrupt is generated when the number of characters in the FIFO
equals the programmed trigger level. However, the FIFO will continue to
be loaded until it is full. Refer to
Table 11
.
5-4
FCR[5]
(MSB),
FCR[4]
(LSB)
Logic 0 or cleared is the default condition; TX trigger level = 16.
These bits are used to set the trigger level for the transmit FIFO
interrupt. The SC16C650A will issue a transmit empty interrupt when the
number of characters in FIFO drops below the selected trigger level.
Refer to
Table 12
.
3
FCR[3]
DMA mode select.
Logic 0 = Set DMA mode `0' (normal default condition).
Logic 1 = Set DMA mode `1'
Transmit operation in mode `0': When the SC16C650A is in the
16C450 mode (FIFOs disabled; FCR[0] = logic 0) or in the FIFO mode
(FIFOs enabled; FCR[0] = logic 1; FCR[3] = logic 0), and when there are
no characters in the transmit FIFO or transmit holding register, the
TXRDY pin will be a logic 0. Once active, the TXRDY pin will go to a
logic 1 after the first character is loaded into the transmit holding
register.
Receive operation in mode `0': When the SC16C650A is in 16C450
mode, or in the FIFO mode (FCR[0] = logic 1; FCR[3] = logic 0) and
there is at least one character in the receive FIFO, the RXRDY pin will
be a logic 0. Once active, the RXRDY pin will go to a logic 1 when there
are no more characters in the receiver.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
21 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Transmit operation in mode `1': When the SC16C650A is in FIFO
mode (FCR[0] = logic 1; FCR[3] = logic 1), the TXRDY pin will be a
logic 1 when the transmit FIFO is completely full. It will be a logic 0 when
the trigger level has been reached.
Receive operation in mode `1': When the SC16C650A is in FIFO
mode (FCR[0] = logic 1; FCR[3] = logic 1) and the trigger level has been
reached, or a Receive Time-Out has occurred, the RXRDY pin will go to
a logic 0. Once activated, it will go to a logic 1 after there are no more
characters in the FIFO.
2
FCR[2]
XMIT FIFO reset.
Logic 0 = No FIFO transmit reset (normal default condition).
Logic 1 = Clears the contents of the transmit FIFO and resets the
FIFO counter logic (the transmit shift register is not cleared or
altered). This bit will return to a logic 0 after clearing the FIFO.
1
FCR[1]
RCVR FIFO reset.
Logic 0 = No FIFO receive reset (normal default condition).
Logic 1 = Clears the contents of the receive FIFO and resets the FIFO
counter logic (the receive shift register is not cleared or altered). This
bit will return to a logic 0 after clearing the FIFO.
0
FCR[0]
FIFO enable.
Logic 0 = Disable the transmit and receive FIFO (normal default
condition).
Logic 1 = Enable the transmit and receive FIFO. This bit must be a
`1' when other FCR bits are written to, or they will not be
programmed.
Table 11:
RCVR trigger levels
FCR[7]
FCR[6]
RX FIFO trigger level (bytes)
0
0
8
0
1
16
1
0
24
1
1
28
Table 12:
TX FIFO trigger levels
FCR[5]
FCR[4]
TX FIFO trigger level (bytes)
0
0
16
0
1
8
1
0
24
1
1
30
Table 10:
FIFO Control Register bits description
...continued
Bit
Symbol
Description
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
22 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.4 Interrupt Status Register (ISR)
The SC16C650A provides six levels of prioritized interrupts to minimize external
software interaction. The Interrupt Status Register (ISR) provides the user with six
interrupt status bits. Performing a read cycle on the ISR will provide the user with the
highest pending interrupt level to be serviced. No other interrupts are acknowledged
until the pending interrupt is serviced. Whenever the interrupt status register is read,
the interrupt status is cleared. However, it should be noted that only the current
pending interrupt is cleared by the read. A lower level interrupt may be seen after
re-reading the interrupt status bits.
Table 13 "Interrupt source"
shows the data values
(bits 0-5) for the six prioritized interrupt levels and the interrupt sources associated
with each of these interrupt levels.
Table 13:
Interrupt source
Priority
level
ISR[5]
ISR[4]
ISR[3]
ISR[2]
ISR[1]
ISR[0]
Source of the interrupt
1
0
0
0
1
1
0
LSR (Receiver Line Status
Register)
2
0
0
0
1
0
0
RXRDY (Received Data
Ready)
2
0
0
1
1
0
0
RXRDY (Receive Data
time-out)
3
0
0
0
0
1
0
TXRDY (Transmitter
Holding Register Empty)
4
0
0
0
0
0
0
MSR (Modem Status
Register)
5
0
1
0
0
0
0
RXRDY (Received Xoff
signal) / Special character
6
1
0
0
0
0
0
CTS, RTS change of state
Table 14:
Interrupt Status Register bits description
Bit
Symbol
Description
7-6
ISR[7-6]
FIFOs enabled. These bits are set to a logic 0 when the FIFO is
not being used. They are set to a logic 1 when the FIFOs are
enabled.
Logic 0 or cleared = default condition.
5-4
ISR[5-4]
INT priority bits 4-3. These bits are enabled when EFR[4] is set to
a logic 1. ISR[4] indicates that matching Xoff character(s) have
been detected. ISR[5] indicates that CTS, RTS have been
generated. Note that once set to a logic 1, the ISR[4] bit will stay a
logic 1 until Xon character(s) are received.
Logic 0 or cleared = default condition.
3-1
ISR[3-1]
INT priority bits 2-0. These bits indicate the source for a pending
interrupt at interrupt priority levels 1, 2, and 3 (see
Table 13
).
Logic 0 or cleared = default condition.
0
ISR[0]
INT status.
Logic 0 = An interrupt is pending and the ISR contents may be
used as a pointer to the appropriate interrupt service routine.
Logic 1 = No interrupt pending (normal default condition).
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
23 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.5 Line Control Register (LCR)
The Line Control Register is used to specify the asynchronous data communication
format. The word length, the number of stop bits, and the parity are selected by
writing the appropriate bits in this register.
[1]
When LCR[7] = 1, the general register set cannot be accessed until LCR[7] = 0.
Table 15:
Line Control Register bits description
Bit
Symbol
Description
7
LCR[7]
[1]
Divisor latch enable. The internal baud rate counter latch and Enhance
Feature mode enable.
Logic 0 = Divisor latch disabled (normal default condition).
Logic 1 = Divisor latch and enhanced feature register enabled.
6
LCR[6]
Set break. When enabled, the Break control bit causes a break condition
to be transmitted (the TX output is forced to a logic 0 state). This
condition exists until disabled by setting LCR[6] to a logic 0.
Logic 0 = no TX break condition (normal default condition).
Logic 1 = forces the transmitter output (TX) to a logic 0 for alerting the
remote receiver to a line break condition.
5
LCR[5]
Set parity. If the parity bit is enabled, LCR[5] selects the forced parity
format. Programs the parity conditions (see
Table 16
).
Logic 0 = parity is not forced (normal default condition).
LCR[5] = logic 1 and LCR[4] = logic 0: parity bit is forced to a logical 1
for the transmit and receive data.
LCR[5] = logic 1 and LCR[4] = logic 1: parity bit is forced to a logical 0
for the transmit and receive data.
4
LCR[4]
Even parity. If the parity bit is enabled with LCR[3] set to a logic 1,
LCR[4] selects the even or odd parity format.
Logic 0 = ODD Parity is generated by forcing an odd number of
logic 1s in the transmitted data. The receiver must be programmed to
check the same format (normal default condition).
Logic 1 = EVEN Parity is generated by forcing an even number of
logic 1s in the transmitted data. The receiver must be programmed to
check the same format.
3
LCR[3]
Parity enable. Parity or no parity can be selected via this bit.
Logic 0 = no parity (normal default condition).
Logic 1 = a parity bit is generated during the transmission, receiver
checks the data and parity for transmission errors.
2
LCR[2]
Stop bits. The length of stop bit is specified by this bit in conjunction with
the programmed word length (see
Table 17
).
Logic 0 or cleared = default condition.
1-0
LCR[1-0]
Word length bits 1, 0. These two bits specify the word length to be
transmitted or received (see
Table 18
).
Logic 0 or cleared = default condition.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
24 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.6 Modem Control Register (MCR)
This register controls the interface with the modem or a peripheral device.
Table 16:
LCR[5] parity selection
LCR[5]
LCR[4]
LCR[3]
Parity selection
X
X
0
no parity
0
0
1
ODD parity
0
1
1
EVEN parity
1
0
1
force parity `1'
1
1
1
forced parity `0'
Table 17:
LCR[2] stop bit length
LCR[2]
Word length
Stop bit length (bit times)
0
5, 6, 7, 8
1
1
5
1-
1
/
2
1
6, 7, 8
2
Table 18:
LCR[1-0] word length
LCR[1]
LCR[0]
Word length
0
0
5
0
1
6
1
0
7
1
1
8
Table 19:
Modem Control Register bits description
Bit
Symbol
Description
7
MCR[7]
Clock select.
Logic 0 = Divide-by-1. The input clock (crystal or external) is
divided by 16 and then presented to the Programmable Baud Rate
Generator (BGR) without further modification, i.e., divide-by-1
(normal default condition).
Logic 1 = Divide-by-4. The divide-by-1 clock described in MCR[7]
equals a logic 0, is further divided by four (see also
Section 6.7
"Programmable baud rate generator"
).
6
MCR[6]
IR enable.
Logic 0 = Enable the standard modem receive and transmit
input/output interface (normal default condition).
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs.
While in this mode, the TX/RX output/inputs are routed to the
infrared encoder/decoder. The data input and output levels will
conform to the IrDA infrared interface requirement. As such, while
in this mode, the infrared TX output will be a logic 0 during idle data
conditions.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
25 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
5
MCR[5]
INT typ select.
Logic 0 = Enable active or 3-State interrupt output mode (normal
default condition).
Logic= 1 = Enable open source interrupt output mode. Provides
shared interrupts in the STD mode by producing a wire-OR output
driver capability for interrupts. This output appears at the IRQA/INT
pin. When using this option, an external pull-down resistor of
200 to 500
must be tied from the IRQA/INT pin to ground to
provide and acceptable logic 0 level
4
MCR[4]
Loop-back. Enable the local loop-back mode (diagnostics). In this
mode the transmitter output (TX) and the receiver input (RX), CTS,
DSR, DCD, and RI are disconnected from the SC16C650A I/O pins.
Internally the modem data and control pins are connected into a
loop-back data configuration (see
Figure 7
). In this mode, the receiver
and transmitter interrupts remain fully operational. The Modem
Control Interrupts are also operational, but the interrupts' sources are
switched to the lower four bits of the Modem Control. Interrupts
continue to be controlled by the IER register.
Logic 0 = Disable loop-back mode (normal default condition).
Logic 1 = Enable local loop-back mode (diagnostics).
3
MCR[3]
OUT2, INTx enable. Used to control the modem DCD signal in the
loop-back mode.
Logic 0 = Forces INT output to the 3-State mode. In the loop-back
mode, sets OUT2 (DCD) internally to a logic 1.
Logic 1 = Forces the INT output to the active mode. In the
loop-back mode, sets OUT2 (DCD) internally to a logic 0.
2
MCR[2]
OUT1. This bit is used in the Loop-back mode only. In the loop-back
mode, this bit is used to write the state of the modem RI interface
signal via OUT1.
1
MCR[1]
RTS
Logic 0 = Force RTS output to a logic 1 (normal default condition).
Logic 1 = Force RTS output to a logic 0.
0
MCR[0]
DTR
Logic 0 = Force DTR output to a logic 1 (normal default condition).
Logic 1 = Force DTR output to a logic 0.
Table 19:
Modem Control Register bits description
...continued
Bit
Symbol
Description
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
26 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.7 Line Status Register (LSR)
This register provides the status of data transfers between the SC16C650A and
the CPU.
Table 20:
Line Status Register bits description
Bit
Symbol
Description
7
LSR[7]
FIFO data error.
Logic 0 = No error (normal default condition).
Logic 1 = At least one parity error, framing error or break indication is in
the current FIFO data. This bit is cleared when LSR register is read.
6
LSR[6]
THR and TSR empty. This bit is the Transmit Empty indicator. This bit is
set to a logic 1 whenever the transmit holding register and the transmit
shift register are both empty. It is reset to logic 0 whenever either the THR
or TSR contains a data character. In the FIFO mode, this bit is set to `1'
whenever the transmit FIFO and transmit shift register are both empty.
5
LSR[5]
THR empty. This bit is the Transmit Holding Register Empty indicator.
This bit indicates that the UART is ready to accept a new character for
transmission. In addition, this bit causes the UART to issue an interrupt to
CPU when the THR interrupt enable is set. The THR bit is set to a logic 1
when a character is transferred from the transmit holding register into the
transmitter shift register. The bit is reset to a logic 0 concurrently with the
loading of the transmitter holding register by the CPU. In the FIFO mode,
this bit is set when the transmit FIFO is empty; it is cleared when at least
1 byte is written to the transmit FIFO.
4
LSR[4]
Break interrupt.
Logic 0 = No break condition (normal default condition).
Logic 1 = The receiver received a break signal (RX was a logic 0 for
one character frame time). In the FIFO mode, only one break character
is loaded into the FIFO.
3
LSR[3]
Framing error.
Logic 0 = No framing error (normal default condition).
Logic 1 = Framing error. The receive character did not have a valid stop
bit(s). In the FIFO mode, this error is associated with the character at
the top of the FIFO.
2
LSR[2]
Parity error.
Logic 0 = No parity error (normal default condition).
Logic 1 = Parity error. The receive character does not have correct
parity information and is suspect. In the FIFO mode, this error is
associated with the character at the top of the FIFO.
1
LSR[1]
Overrun error.
Logic 0 = No overrun error (normal default condition).
Logic 1 = Overrun error. A data overrun error occurred in the receive
shift register. This happens when additional data arrives while the FIFO
is full. In this case, the previous data in the shift register is overwritten.
Note that under this condition, the data byte in the receive shift register
is not transferred into the FIFO, therefore the data in the FIFO is not
corrupted by the error.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
27 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.8 Modem Status Register (MSR)
This register provides the current state of the control interface signals from the
modem, or other peripheral device to which the SC16C650A is connected. Four bits
of this register are used to indicate the changed information. These bits are set to a
logic 1 whenever a control input from the modem changes state. These bits are set to
a logic 0 whenever the CPU reads this register.
0
LSR[0]
Receive data ready.
Logic 0 = No data in receive holding register or FIFO (normal default
condition).
Logic 1 = Data has been received and is saved in the receive holding
register or FIFO.
Table 20:
Line Status Register bits description
...continued
Bit
Symbol
Description
Table 21:
Modem Status Register bits description
Bit
Symbol
Description
7
MSR[7]
Data Carrier Detect. DCD (Active-HIGH, logical 1). Normally this bit is
the complement of the DCD input. In the loop-back mode this bit is
equivalent to the OUT2 bit in the MCR register.
6
MSR[6]
Ring Indicator. RI (Active-HIGH, logical 1). Normally this bit is the
complement of the RI input. In the loop-back mode this bit is equivalent
to the OUT1 bit in the MCR register.
5
MSR[5]
Data Set Ready. DSR (Active-HIGH, logical 1). Normally this bit is the
complement of the DSR input. In loop-back mode this bit is equivalent to
the DTR bit in the MCR register.
4
MSR[4]
Clear To Send. CTS. CTS functions as hardware flow control signal input
if it is enabled via EFR[7]. Flow control (when enabled) allows starting
and stopping the transmissions based on the external modem CTS
signal. A logic 1 at the CTS pin will stop SC16C650A transmissions as
soon as current character has finished transmission. Normally MSR[4] is
the complement of the CTS input. However, in the loop-back mode, this
bit is equivalent to the RTS bit in the MCR register.
3
MSR[3]
DCD
[1]
Logic 0 = No DCD change (normal default condition).
Logic 1 = The DCD input to the SC16C650A has changed state since
the last time it was read. A modem Status Interrupt will be generated.
2
MSR[2]
RI
[1]
Logic 0 = No RI change (normal default condition).
Logic 1 = The RI input to the SC16C650A has changed from a logic 0
to a logic 1. A modem Status Interrupt will be generated.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
28 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
[1]
Whenever any MSR bit 0-3 is set to logic 1, a Modem Status Interrupt will be generated.
7.9 Scratchpad Register (SPR)
The SC16C650A provides a temporary data register to store 8 bits of user
information.
7.10 Enhanced Feature Register (EFR)
Enhanced features are enabled or disabled using this register.
Bits 0 through 4 provide single or dual character software flow control selection.
When the Xon1 and Xon2 and/or Xoff1 and Xoff2 modes are selected, the double
8-bit words are concatenated into two sequential numbers.
1
MSR[1]
DSR
[1]
Logic 0 = No DSR change (normal default condition).
Logic 1 = The DSR input to the SC16C650A has changed state since
the last time it was read. A modem Status Interrupt will be generated.
0
MSR[0]
CTS
[1]
Logic 0 = No CTS change (normal default condition).
Logic 1 = The CTS input to the SC16C650A has changed state since
the last time it was read. A modem Status Interrupt will be generated.
Table 21:
Modem Status Register bits description
...continued
Bit
Symbol
Description
Table 22:
Enhanced Feature Register bits description
Bit
Symbol
Description
7
EFR[7]
Automatic CTS flow control.
Logic 0 = Automatic CTS flow control is disabled (normal default
condition).
Logic 1 = Enable Automatic CTS flow control. Transmission will stop
when CTS goes to a logical 1. Transmission will resume when the CTS
pin returns to a logical 0.
6
EFR[6]
Automatic RTS flow control. Automatic RTS may be used for hardware flow
control by enabling EFR[6]. When Auto-RTS is selected, an interrupt will
be generated when the receive FIFO is filled to the programmed trigger
level and RTS will go to a logic 1 at the next trigger level. RTS will return to
a logic 0 when data is unloaded below the next lower trigger level
(programmed trigger level 1). The state of this register bit changes with the
status of the hardware flow control. RTS functions normally when
hardware flow control is disabled.
0 = Automatic RTS flow control is disabled (normal default condition).
1 = Enable Automatic RTS flow control.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
29 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
[1]
When using a software flow control the Xon/Xoff characters cannot be used for data transfer.
5
EFR[5]
Special Character Detect.
Logic 0 = Special character detect disabled (normal default condition).
Logic 1 = Special character detect enabled. The SC16C650A compares
each incoming receive character with Xoff2 data. If a match exists, the
received data will be transferred to FIFO and ISR[4] will be set to
indicate detection of special character. Bit-0 in the X-registers
corresponds with the LSB bit for the receive character. When this feature
is enabled, the normal software flow control must be disabled (EFR[3-0]
must be set to a logic 0).
4
EFR[4]
Enhanced function control bit. The content of IER[7-4], ISR[5-4], FCR[5-4],
and MCR[7-5] can be modified and latched. After modifying any bits in the
enhanced registers, EFR[4] can be set to a logic 0 to latch the new values.
This feature prevents existing software from altering or overwriting the
SC16C650A enhanced functions.
Logic 0 = Disable (normal default condition).
Logic 1 = Enable.
3-0
EFR[3-0] Cont-3-0 Tx, Rx control. Logic 0 or cleared is the default condition.
Combinations of software flow control can be selected by programming
these bits. See
Table 23
.
Table 23:
Software flow control functions
[1]
Cont-3
Cont-2
Cont-1
Cont-0
TX, RX software flow controls
0
0
X
X
No transmit flow control
1
0
X
X
Transmit Xon1/Xoff1
0
1
X
X
Transmit Xon2/Xoff2
1
1
X
X
Transmit Xon1 and Xon2/Xoff1 and Xoff2
X
X
0
0
No receive flow control
X
X
1
0
Receiver compares Xon1/Xoff1
X
X
0
1
Receiver compares Xon2/Xoff2
1
0
1
1
Transmit Xon1/Xoff1
Receiver compares Xon1 and Xon2, Xoff1 and Xoff2
0
1
1
1
Transmit Xon2/Xoff2
Receiver compares Xon1 and Xon2/Xoff1 and Xoff2
1
1
1
1
Transmit Xon1 and Xon2/Xoff1 and Xoff2
Receiver compares Xon1 and Xon2/Xoff1 and Xoff2
Table 22:
Enhanced Feature Register bits description
...continued
Bit
Symbol
Description
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
30 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
7.11 SC16C650A external reset conditions
8.
Limiting values
Table 24:
Reset state for registers
Register
Reset state
IER
IER[7-0] = 0
ISR
ISR[7-1] = 0; ISR[0] = 1
LCR
LCR[7-0] = 0
MCR
MCR[7-0] = 0
LSR
LSR[7] = 0; LSR[6-5] = 1; LSR[4-0] = 0
MSR
MSR[7-4] = input signals; MSR[3-0] = 0
FCR
FCR[7-0] = 0
EFR
EFR[7-0] = 0
Table 25:
Reset state for outputs
Output
Reset state
TX
HIGH
RTS
HIGH
DTR
HIGH
RXRDY
HIGH (STD mode)
TXRDY
LOW (STD mode)
INT
LOW (STD mode)
Table 26:
Limiting values
In accordance with the Absolute Maximum Rating System (IEC 60134).
Symbol
Parameter
Conditions
Min
Max
Unit
V
CC
supply voltage
-
7
V
V
n
voltage at any pin
GND
-
0.3
V
CC
+ 0.3
V
T
amb
operating temperature
-
40
+85
C
T
stg
storage temperature
-
65
+150
C
P
tot(pack)
total power dissipation per
package
-
500
mW
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
31 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
9.
Static characteristics
[1]
Except for x
2
, V
OL
= 1 V typically.
[2]
Refer to
Table 2 "Pin description" on page 6
for a listing of pins having internal pull-up resistors.
Table 27:
DC electrical characteristics
T
amb
=
-
40
C to +85
C; V
CC
= 2.5 V, 3.3 V or 5.0 V
10%, unless otherwise specified.
Symbol
Parameter
Conditions
2.5 V
3.3 V
5.0 V
Unit
Min
Max
Min
Max
Min
Max
V
IL(CK)
LOW-level clock input voltage
-
0.3
0.45
-
0.3
0.6
-
0.5
0.6
V
V
IH(CK)
HIGH-level clock input voltage
1.8
V
CC
2.4
V
CC
3.0
V
CC
V
V
IL
LOW-level input voltage
-
0.3
0.65
-
0.3
0.8
-
0.5
0.8
V
V
IH
HIGH-level input voltage
1.6
-
2.0
-
2.2
V
CC
V
V
OL
LOW-level output voltage
on all outputs
[1]
I
OL
= 5 mA
(databus)
-
-
-
-
-
0.4
V
I
OL
= 4 mA
(other outputs)
-
-
-
0.4
-
-
V
I
OL
= 2 mA
(databus)
-
0.4
-
-
-
-
V
I
OL
= 1.6 mA
(other outputs)
-
0.4
-
-
-
-
V
V
OH
HIGH-level output voltage
I
OH
=
-
5 mA
(databus)
-
-
-
-
2.4
-
V
I
OH
=
-
1 mA
(other outputs)
-
-
2.0
-
-
-
V
I
OH
=
-
800
A
(databus)
1.85
-
-
-
-
-
V
I
OH
=
-
400
A
(other outputs)
1.85
-
-
-
-
-
V
I
LIL
LOW-level input leakage current
-
10
-
10
-
10
A
I
CL
clock leakage
-
30
-
30
-
30
A
I
CC
average power supply current
f = 5 MHz
-
3.5
-
4.5
-
4.5
mA
C
i
input capacitance
-
5
-
5
-
5
pF
R
pu(int)
internal pull-up resistance
[2]
500
-
500
-
500
-
k
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
32 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
10. Dynamic characteristics
Table 28:
AC electrical characteristics
T
amb
=
-
40
C to +85
C; V
CC
= 2.5 V, 3.3 V or 5 V
10%, unless otherwise specified.
Symbol
Parameter
Conditions
2.5 V
3.3 V
5.0 V
Unit
Min
Max
Min
Max
Min
Max
t
1w
, t
2w
clock pulse duration
15
-
13
-
10
-
ns
t
3w
oscillator/clock frequency
[1]
-
16
-
32
-
48
MHz
t
4w
address strobe width
45
-
35
-
25
-
ns
t
5s
address set-up time
5
-
5
-
1
-
ns
t
5h
address hold time
5
-
5
-
5
-
ns
t
6s
chip select set-up time to AS
10
-
5
-
0
-
ns
t
6h
address hold time
0
-
0
-
0
-
ns
t
6s'
address set-up time
[2]
10
-
10
-
5
-
ns
t
6h
chip select hold time
0
-
0
-
0
-
ns
t
7d
IOR delay from chip select
10
-
10
-
10
-
ns
t
7w
IOR strobe width
25 pF load
77
-
26
-
23
-
ns
t
7h
chip select hold time from IOR
0
-
0
-
0
-
ns
t
7h'
address hold time
[2]
5
-
5
-
5
-
ns
t
8d
IOR delay from address
10
-
10
-
10
-
ns
t
9d
read cycle delay
25 pF load
20
-
20
-
20
-
ns
t
11d
IOR to DDIS delay
25 pF load
-
100
-
35
-
30
ns
t
12d
delay from IOR to data
25 pF load
-
77
-
26
-
23
ns
t
12h
data disable time
25 pF load
-
15
-
15
-
15
ns
t
13d
IOW delay from chip select
10
-
10
-
10
-
ns
t
13w
IOW strobe width
[3]
20
-
20
-
15
-
ns
t
13h
chip select hold time from IOW
0
-
0
-
0
-
ns
t
14d
IOW delay from address
10
-
10
-
10
-
ns
t
15d
write cycle delay
[4]
25
-
25
-
20
-
ns
t
16s
data set-up time
20
-
20
-
15
-
ns
t
16h
data hold time
15
-
5
-
5
-
ns
t
17d
delay from IOW to output
25 pF load
-
100
-
33
-
29
ns
t
18d
delay to set interrupt from Modem
input
25 pF load
-
100
-
24
-
23
ns
t
19d
delay to reset interrupt from IOR
25 pF load
-
100
-
24
-
23
ns
t
20d
delay from stop to set interrupt
-
1
-
1
-
1
R
clk
t
21d
delay from IOR to reset interrupt
25 pF load
-
100
-
29
-
28
ns
t
22d
delay from start to set interrupt
-
100
-
45
-
40
ns
t
23d
delay from IOW to transmit start
8
24
8
24
8
24
R
clk
t
24d
delay from IOW to reset interrupt
-
100
-
45
-
40
ns
t
25d
delay from stop to set RXRDY
-
1
-
1
-
1
R
clk
t
26d
delay from IOR to reset RXRDY
-
100
-
45
-
40
ns
t
27d
delay from IOW to set TXRDY
-
100
-
45
-
40
ns
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
33 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
[1]
Applies to external clock, crystal oscillator max 24 MHz.
[2]
Applicable only when AS is tied LOW.
[3]
= 333 ns (for Baudrate
max
= 1.5 Mbits/s)
= 1
s (for Baudrate
max
= 460.8 kbits/s)
= 4
s (for Baudrate
max
= 115.2 kbits/s)
[4]
When in both DMA mode 0 and FIFO enable mode, the write cycle delay should be larger than one x
1
clock cycle.
10.1 Timing diagrams
t
28d
delay from start to reset TXRDY
-
8
-
8
-
8
R
clk
t
RESET
Reset pulse width
100
-
40
-
40
-
ns
N
baud rate divisor
1
2
16
-
1
1
2
16
-
1
1
2
16
-
1
R
clk
Table 28:
AC electrical characteristics
...continued
T
amb
=
-
40
C to +85
C; V
CC
= 2.5 V, 3.3 V or 5 V
10%, unless otherwise specified.
Symbol
Parameter
Conditions
2.5 V
3.3 V
5.0 V
Unit
Min
Max
Min
Max
Min
Max
IOWstrobe
max
1
2 Baudrate
max
(
)
--------------------------------------
=
Fig 8.
General read timing when using AS signal.
DATA
ACTIVE
VALID
VALID
ADDRESS
002aaa331
t
4w
t
7d
t
5s
t
7w
A0A2
CS2
CS1CS0
IOR, IOR
D0D7
t
5h
t
6h
t
6s
t
8d
t
7h
t
9d
DDIS
t
11d
t
11d
ACTIVE
t
12d
t
12h
AS
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
34 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 9.
General write timing when using AS signal.
DATA
ACTIVE
VALID
VALID
ADDRESS
002aaa332
t
4w
t
13d
t
5s
t
13w
A0A2
CS2
CS1CS0
IOW, IOW
D0D7
t
5h
t
6h
t
6s
t
14d
t
13h
t
15d
t
16s
t
16h
AS
Fig 10. General read timing when AS is tied to GND.
DATA
ACTIVE
ACTIVE
VALID
ADDRESS
002aaa333
t
6s
t
7h
t
7w
t
9d
t
12d
t
12h
A0A2
CS
IOR
D0D7
t
7h
VALID
ADDRESS
t
6s
ACTIVE
t
7w
t
12d
t
12h
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
35 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 11. General write timing when AS is tied to GND.
DATA
ACTIVE
ACTIVE
VALID
ADDRESS
002aaa334
t
6s
t
7h
t
13w
t
15d
t
16s
t
16h
A0A2
CS
IOW
D0D7
t
7h
VALID
ADDRESS
t
6s
ACTIVE
t
13w
t
16s
t
16h
Fig 12. Modem input/output timing.
t
17d
ACTIVE
IOW
CHANGE OF STATE
CHANGE OF STATE
RTS
DTR
DCD
CTS
DSR
CHANGE OF STATE
CHANGE OF STATE
CHANGE OF STATE
ACTIVE
ACTIVE
ACTIVE
t
18d
t
18d
INT
ACTIVE
ACTIVE
ACTIVE
IOR
RI
t
19d
002aaa351
t
18d
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
36 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 13. External clock timing.
t
2w
EXTERNAL
CLOCK
002aaa112
t
1w
t
3w
Fig 14. Receive timing.
D0
D1
D2
D3
D4
D5
D6
D7
ACTIVE
ACTIVE
16 BAUD RATE CLOCK
002aaa113
t
21d
NEXT
DATA
START
BIT
STOP
BIT
PARITY
BIT
START
BIT
t
20d
RX
INT
IOR
DATA BITS (5-8)
5 DATA BITS
6 DATA BITS
7 DATA BITS
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
37 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 15. Receive ready timing in non-FIFO mode.
D0
D1
D2
D3
D4
D5
D6
D7
ACTIVE
DATA
READY
ACTIVE
002aaa114
t
26d
NEXT
DATA
START
BIT
STOP
BIT
PARITY
BIT
START
BIT
t
25d
RX
RXRDY
IOR
DATA BITS (58)
Fig 16. Receive ready timing in FIFO mode.
D0
D1
D2
D3
D4
D5
D6
D7
ACTIVE
DATA
READY
ACTIVE
002aaa115
t
26d
STOP
BIT
PARITY
BIT
START
BIT
t
25d
RX
RXRDY
IOR
DATA BITS (58)
FIRST BYTE THAT
REACHES THE
TRIGGER LEVEL
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
38 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 17. Transmit timing.
D0
D1
D2
D3
D4
D5
D6
D7
ACTIVE TX READY
ACTIVE
16 BAUD RATE CLOCK
002aaa116
t
24d
NEXT
DATA
START
BIT
STOP
BIT
PARITY
BIT
START
BIT
t
22d
TX
INT
IOW
DATA BITS (58)
5 DATA BITS
6 DATA BITS
7 DATA BITS
ACTIVE
t
23d
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
39 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 18. Transmit ready timing in non-FIFO mode.
D0
D1
D2
D3
D4
D5
D6
D7
TRANSMITTER
NOT READY
===!"#
NEXT
DATA
START
BIT
STOP
BIT
PARITY
BIT
START
BIT
t
27d
TX
TXRDY
IOW
DATA BITS (58)
ACTIVE
D0D7
BYTE #1
ACTIVE
TRANSMITTER READY
t
28d
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
40 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 19. Transmit ready timing in FIFO mode (DMA mode `1').
D0
D1
D2
D3
D4
D5
D6
D7
FIFO FULL
002aaa346
STOP
BIT
PARITY
BIT
START
BIT
t
27d
TX
TXRDY
IOW
DATA BITS (5-8)
ACTIVE
D0D7
BYTE #16
5 DATA BITS
6 DATA BITS
7 DATA BITS
t
28d
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
41 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 20. Infrared transmit timing.
Fig 21. Infrared receive timing.
0
1
0
1
0
0
1
1
1
0
DATA BITS
UART FRAME
ST
AR
T
ST
OP
TX DATA
IRTXAIRTXD
TX
BIT
TIME
1/2 BIT TIME
3/16 BIT TIME
002aaa212
0
1
0
1
0
0
1
1
1
0
DATA BITS
UART FRAME
ST
AR
T
ST
OP
RX DATA
IRRXAIRRXD
RX
BIT
TIME
002aaa213
0-1 16X CLOCK DELAY
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
42 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
11. Package outline
Fig 22. PLCC44 (SOT187-2).
UNIT
A
A1
min.
A4
max.
bp
e
y
w
v
REFERENCES
OUTLINE
VERSION
EUROPEAN
PROJECTION
ISSUE DATE
IEC
JEDEC
JEITA
mm
4.57
4.19
0.51
3.05
0.53
0.33
0.021
0.013
16.66
16.51
1.27
17.65
17.40
2.16
45
o
0.18
0.1
0.18
DIMENSIONS (mm dimensions are derived from the original inch dimensions)
Note
1. Plastic or metal protrusions of 0.25 mm (0.01 inch) maximum per side are not included.
SOT187-2
D
(1)
E
(1)
16.66
16.51
HD
HE
17.65
17.40
ZD
(1)
max.
ZE
(1)
max.
2.16
b1
0.81
0.66
k
1.22
1.07
0.180
0.165
0.02
0.12
A3
0.25
0.01
0.656
0.650
0.05
0.695
0.685
0.085
0.007 0.004
0.007
Lp
1.44
1.02
0.057
0.040
0.656
0.650
0.695
0.685
eD
eE
16.00
14.99
0.63
0.59
16.00
14.99
0.63
0.59
0.085
0.032
0.026
0.048
0.042
29
39
44
1
6
7
17
28
18
40
detail X
(A )
3
b
p
w
M
A
1
A
A
4
L
p
b
1
k
X
y
e
E
B
D
H
E
e
E
H
v
M
B
D
Z D
A
Z E
e
v
M
A
pin 1 index
112E10
MS-018
EDR-7319
0
5
10 mm
scale
99-12-27
01-11-14
inches
PLCC44: plastic leaded chip carrier; 44 leads
SOT187-2
D
e
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
43 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 23. LQFP48 (SOT313-2).
UNIT
A
max.
A
1
A
2
A
3
b
p
c
E
(1)
e
H
E
L
L
p
Z
y
w
v
REFERENCES
OUTLINE
VERSION
EUROPEAN
PROJECTION
ISSUE DATE
IEC
JEDEC
JEITA
mm
1.6
0.20
0.05
1.45
1.35
0.25
0.27
0.17
0.18
0.12
7.1
6.9
0.5
9.15
8.85
0.95
0.55
7
0
o
o
0.12
0.1
0.2
1
DIMENSIONS (mm are the original dimensions)
Note
1. Plastic or metal protrusions of 0.25 mm maximum per side are not included.
0.75
0.45
SOT313-2
MS-026
136E05
00-01-19
03-02-25
D
(1)
(1)
(1)
7.1
6.9
H
D
9.15
8.85
E
Z
0.95
0.55
D
b
p
e
E
B
12
D
H
b
p
E
H
v
M
B
D
ZD
A
Z E
e
v
M
A
1
48
37
36
25
24
13
A
1
A
L
p
detail X
L
(A )
3
A
2
X
y
c
w
M
w
M
0
2.5
5 mm
scale
pin 1 index
LQFP48: plastic low profile quad flat package; 48 leads; body 7 x 7 x 1.4 mm
SOT313-2
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
44 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Fig 24. DIP40 (SOT129-1).
UNIT
A
max.
1
2
b
1
c
D
E
e
M
H
L
REFERENCES
OUTLINE
VERSION
EUROPEAN
PROJECTION
ISSUE DATE
IEC
JEDEC
JEITA
mm
inches
DIMENSIONS (inch dimensions are derived from the original mm dimensions)
SOT129-1
99-12-27
03-02-13
A
min.
A
max.
b
Z
max.
w
M
E
e
1
1.70
1.14
0.53
0.38
0.36
0.23
52.5
51.5
14.1
13.7
3.60
3.05
0.254
2.54
15.24
15.80
15.24
17.42
15.90
2.25
4.7
0.51
4
0.067
0.045
0.021
0.015
0.014
0.009
2.067
2.028
0.56
0.54
0.14
0.12
0.01
0.1
0.6
0.62
0.60
0.69
0.63
0.089
0.19
0.02
0.16
051G08
MO-015
SC-511-40
M
H
c
(e )
1
M
E
A
L
seating plane
A
1
w
M
b
1
e
D
A
2
Z
40
1
21
20
b
E
pin 1 index
0
5
10 mm
scale
Note
1. Plastic or metal protrusions of 0.25 mm (0.01 inch) maximum per side are not included.
(1)
(1)
(1)
DIP40: plastic dual in-line package; 40 leads (600 mil)
SOT129-1
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
45 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
12. Soldering
12.1 Introduction
This text gives a very brief insight to a complex technology. A more in-depth account
of soldering ICs can be found in our
Data Handbook IC26; Integrated Circuit
Packages (document order number 9398 652 90011).
There is no soldering method that is ideal for all IC packages. Wave soldering is often
preferred when through-hole and surface mount components are mixed on one
printed-circuit board. Wave soldering can still be used for certain surface mount ICs,
but it is not suitable for fine pitch SMDs. In these situations reflow soldering is
recommended. Driven by legislation and environmental forces the worldwide use of
lead-free solder pastes is increasing.
12.2 Through-hole mount packages
12.2.1
Soldering by dipping or by solder wave
Typical dwell time of the leads in the wave ranges from 3 to 4 seconds at 250
C or
265
C, depending on solder material applied, SnPb or Pb-free respectively.
The total contact time of successive solder waves must not exceed 5 seconds.
The device may be mounted up to the seating plane, but the temperature of the
plastic body must not exceed the specified maximum storage temperature (T
stg(max)
).
If the printed-circuit board has been pre-heated, forced cooling may be necessary
immediately after soldering to keep the temperature within the permissible limit.
12.2.2
Manual soldering
Apply the soldering iron (24 V or less) to the lead(s) of the package, either below the
seating plane or not more than 2 mm above it. If the temperature of the soldering iron
bit is less than 300
C it may remain in contact for up to 10 seconds. If the bit
temperature is between 300 and 400
C, contact may be up to 5 seconds.
12.3 Surface mount packages
12.3.1
Reflow soldering
Reflow soldering requires solder paste (a suspension of fine solder particles, flux and
binding agent) to be applied to the printed-circuit board by screen printing, stencilling
or pressure-syringe dispensing before package placement.
Several methods exist for reflowing; for example, convection or convection/infrared
heating in a conveyor type oven. Throughput times (preheating, soldering and
cooling) vary between 100 and 200 seconds depending on heating method.
Typical reflow peak temperatures range from 215 to 270
C depending on solder
paste material. The top-surface temperature of the packages should preferably be
kept:
below 220
C (SnPb process) or below 245
C (Pb-free process)
for all the BGA and SSOP-T packages
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
46 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
for packages with a thickness
2.5 mm
for packages with a thickness < 2.5 mm and a volume
350 mm
3
so called
thick/large packages.
below 235
C (SnPb process) or below 260
C (Pb-free process) for packages with
a thickness < 2.5 mm and a volume < 350 mm
3
so called small/thin packages.
Moisture sensitivity precautions, as indicated on packing, must be respected at all
times.
12.3.2
Wave soldering
Conventional single wave soldering is not recommended for surface mount devices
(SMDs) or printed-circuit boards with a high component density, as solder bridging
and non-wetting can present major problems.
To overcome these problems the double-wave soldering method was specifically
developed.
If wave soldering is used the following conditions must be observed for optimal
results:
Use a double-wave soldering method comprising a turbulent wave with high
upward pressure followed by a smooth laminar wave.
For packages with leads on two sides and a pitch (e):
larger than or equal to 1.27 mm, the footprint longitudinal axis is preferred to be
parallel to the transport direction of the printed-circuit board;
smaller than 1.27 mm, the footprint longitudinal axis must be parallel to the
transport direction of the printed-circuit board.
The footprint must incorporate solder thieves at the downstream end.
For packages with leads on four sides, the footprint must be placed at a 45
angle
to the transport direction of the printed-circuit board. The footprint must
incorporate solder thieves downstream and at the side corners.
During placement and before soldering, the package must be fixed with a droplet of
adhesive. The adhesive can be applied by screen printing, pin transfer or syringe
dispensing. The package can be soldered after the adhesive is cured.
Typical dwell time of the leads in the wave ranges from 3 to 4 seconds at 250
C or
265
C, depending on solder material applied, SnPb or Pb-free respectively.
A mildly-activated flux will eliminate the need for removal of corrosive residues in
most applications.
12.3.3
Manual soldering
Fix the component by first soldering two diagonally-opposite end leads. Use a low
voltage (24 V or less) soldering iron applied to the flat part of the lead. Contact time
must be limited to 10 seconds at up to 300
C.
When using a dedicated tool, all other leads can be soldered in one operation within
2 to 5 seconds between 270 and 320
C.
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
47 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
12.4 Package related soldering information
[1]
For more detailed information on the BGA packages refer to the
(LF)BGA Application Note
(AN01026); order a copy from your Philips Semiconductors sales office.
[2]
All surface mount (SMD) packages are moisture sensitive. Depending upon the moisture content, the
maximum temperature (with respect to time) and body size of the package, there is a risk that internal
or external package cracks may occur due to vaporization of the moisture in them (the so called
popcorn effect). For details, refer to the Drypack information in the
Data Handbook IC26; Integrated
Circuit Packages; Section: Packing Methods.
[3]
For SDIP packages, the longitudinal axis must be parallel to the transport direction of the
printed-circuit board.
[4]
These transparent plastic packages are extremely sensitive to reflow soldering conditions and must
on no account be processed through more than one soldering cycle or subjected to infrared reflow
soldering with peak temperature exceeding 217
C
10
C measured in the atmosphere of the reflow
oven. The package body peak temperature must be kept as low as possible.
[5]
These packages are not suitable for wave soldering. On versions with the heatsink on the bottom
side, the solder cannot penetrate between the printed-circuit board and the heatsink. On versions with
the heatsink on the top side, the solder might be deposited on the heatsink surface.
[6]
If wave soldering is considered, then the package must be placed at a 45
angle to the solder wave
direction. The package footprint must incorporate solder thieves downstream and at the side corners.
[7]
Wave soldering is suitable for LQFP, QFP and TQFP packages with a pitch (e) larger than 0.8 mm; it
is definitely not suitable for packages with a pitch (e) equal to or smaller than 0.65 mm.
[8]
Wave soldering is suitable for SSOP and TSSOP packages with a pitch (e) equal to or larger than
0.65 mm; it is definitely not suitable for packages with a pitch (e) equal to or smaller than 0.5 mm.
Table 29:
Suitability of IC packages for wave, reflow and dipping soldering methods
Mounting
Package
[1]
Soldering method
Wave
Reflow
[2]
Dipping
Through-hole
mount
DBS, DIP, HDIP, SDIP, SIL suitable
[3]
-
suitable
Surface mount
BGA, LBGA, LFBGA,
SQFP, SSOP-T
[4]
,
TFBGA, VFBGA
not suitable
suitable
-
DHVQFN, HBCC, HBGA,
HLQFP, HSQFP, HSOP,
HTQFP, HTSSOP,
HVQFN, HVSON, SMS
not suitable
[5]
suitable
-
PLCC
[6]
, SO, SOJ
suitable
suitable
-
LQFP, QFP, TQFP
not recommended
[6][7]
suitable
-
SSOP, TSSOP, VSO,
VSSOP
not recommended
[8]
suitable
-
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Product data
Rev. 04 -- 20 June 2003
48 of 50
9397 750 11622
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
13. Revision history
Table 30:
Revision history
Rev Date
CPCN
Description
04
20030620
-
Product data (9397 750 11622). ECN 853-2378 30030 of 16 June 2003.
Modifications:
Figure 5 "Crystal oscillator connection." on page 13
: Capacitors' values changed and
added connection with resistor.
03
20030313
-
Product data (9397 750 11207). ECN 853-2378 29622 of 07 March 2003.
02
20021211
-
Product data (9397 750 10812). ECN 853-2378 29261 of 06 December 2002.
01
20020910
-
Product data (9397 750 09832). ECN 853-2378 28891 of 10 September 2002.
9397 750 11622
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
Koninklijke Philips Electronics N.V. 2003. All rights reserved.
Product data
Rev. 04 -- 20 June 2003
49 of 50
Contact information
For additional information, please visit http://www.semiconductors.philips.com.
For sales office addresses, send e-mail to: sales.addresses@www.semiconductors.philips.com.
Fax: +31 40 27 24825
14. Data sheet status
[1]
Please consult the most recently issued data sheet before initiating or completing a design.
[2]
The product status of the device(s) described in this data sheet may have changed since this data sheet was published. The latest information is available on the Internet at
URL http://www.semiconductors.philips.com.
[3]
For data sheets describing multiple type numbers, the highest-level product status determines the data sheet status.
15. Definitions
Short-form specification -- The data in a short-form specification is
extracted from a full data sheet with the same type number and title. For
detailed information see the relevant data sheet or data handbook.
Limiting values definition -- Limiting values given are in accordance with
the Absolute Maximum Rating System (IEC 60134). Stress above one or
more of the limiting values may cause permanent damage to the device.
These are stress ratings only and operation of the device at these or at any
other conditions above those given in the Characteristics sections of the
specification is not implied. Exposure to limiting values for extended periods
may affect device reliability.
Application information -- Applications that are described herein for any
of these products are for illustrative purposes only. Philips Semiconductors
make no representation or warranty that such applications will be suitable for
the specified use without further testing or modification.
16. Disclaimers
Life support -- These products are not designed for use in life support
appliances, devices, or systems where malfunction of these products can
reasonably be expected to result in personal injury. Philips Semiconductors
customers using or selling these products for use in such applications do so
at their own risk and agree to fully indemnify Philips Semiconductors for any
damages resulting from such application.
Right to make changes -- Philips Semiconductors reserves the right to
make changes in the products - including circuits, standard cells, and/or
software - described or contained herein in order to improve design and/or
performance. When the product is in full production (status `Production'),
relevant changes will be communicated via a Customer Product/Process
Change Notification (CPCN). Philips Semiconductors assumes no
responsibility or liability for the use of any of these products, conveys no
licence or title under any patent, copyright, or mask work right to these
products, and makes no representations or warranties that these products are
free from patent, copyright, or mask work right infringement, unless otherwise
specified.
Level
Data sheet status
[1]
Product status
[2][3]
Definition
I
Objective data
Development
This data sheet contains data from the objective specification for product development. Philips
Semiconductors reserves the right to change the specification in any manner without notice.
II
Preliminary data
Qualification
This data sheet contains data from the preliminary specification. Supplementary data will be published
at a later date. Philips Semiconductors reserves the right to change the specification without notice, in
order to improve the design and supply the best possible product.
III
Product data
Production
This data sheet contains data from the product specification. Philips Semiconductors reserves the
right to make changes at any time in order to improve the design, manufacturing and supply. Relevant
changes will be communicated via a Customer Product/Process Change Notification (CPCN).
Koninklijke Philips Electronics N.V. 2003.
Printed in the U.S.A
All rights are reserved. Reproduction in whole or in part is prohibited without the prior
written consent of the copyright owner.
The information presented in this document does not form part of any quotation or
contract, is believed to be accurate and reliable and may be changed without notice. No
liability will be accepted by the publisher for any consequence of its use. Publication
thereof does not convey nor imply any license under patent- or other industrial or
intellectual property rights.
Date of release: 20 June 2003
Document order number: 9397 750 11622
Contents
Philips Semiconductors
SC16C650A
UART with 32-byte FIFO and IrDA encoder/decoder
1
General description . . . . . . . . . . . . . . . . . . . . . . 1
2
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3
Ordering information . . . . . . . . . . . . . . . . . . . . . 2
4
Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . 3
5
Pinning information . . . . . . . . . . . . . . . . . . . . . . 4
5.1
Pinning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5.2
Pin description . . . . . . . . . . . . . . . . . . . . . . . . . 6
6
Functional description . . . . . . . . . . . . . . . . . . . 9
6.1
Internal registers . . . . . . . . . . . . . . . . . . . . . . . 10
6.2
FIFO operation . . . . . . . . . . . . . . . . . . . . . . . . 10
6.3
Hardware flow control . . . . . . . . . . . . . . . . . . . 11
6.4
Software flow control . . . . . . . . . . . . . . . . . . . 11
6.5
Special feature software flow control . . . . . . . 12
6.6
Hardware/software and time-out interrupts. . . 12
6.7
Programmable baud rate generator . . . . . . . . 13
6.8
DMA operation . . . . . . . . . . . . . . . . . . . . . . . . 15
6.9
Sleep mode. . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6.10
Loop-back mode . . . . . . . . . . . . . . . . . . . . . . . 15
7
Register descriptions . . . . . . . . . . . . . . . . . . . 17
7.1
Transmit (THR) and Receive (RHR)
Holding Registers . . . . . . . . . . . . . . . . . . . . . 18
7.2
Interrupt Enable Register (IER) . . . . . . . . . . . 18
7.2.1
IER versus Receive FIFO interrupt
mode operation . . . . . . . . . . . . . . . . . . . . . . . 19
7.2.2
IER versus Receive/Transmit FIFO polled
mode operation . . . . . . . . . . . . . . . . . . . . . . . 19
7.3
FIFO Control Register (FCR) . . . . . . . . . . . . . 20
7.3.1
DMA mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.3.2
FIFO mode . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7.4
Interrupt Status Register (ISR) . . . . . . . . . . . . 22
7.5
Line Control Register (LCR) . . . . . . . . . . . . . . 23
7.6
Modem Control Register (MCR) . . . . . . . . . . . 24
7.7
Line Status Register (LSR) . . . . . . . . . . . . . . . 26
7.8
Modem Status Register (MSR). . . . . . . . . . . . 27
7.9
Scratchpad Register (SPR) . . . . . . . . . . . . . . 28
7.10
Enhanced Feature Register (EFR) . . . . . . . . . 28
7.11
SC16C650A external reset conditions . . . . . . 30
8
Limiting values . . . . . . . . . . . . . . . . . . . . . . . . 30
9
Static characteristics . . . . . . . . . . . . . . . . . . . 31
10
Dynamic characteristics . . . . . . . . . . . . . . . . . 32
10.1
Timing diagrams. . . . . . . . . . . . . . . . . . . . . . . 33
11
Package outline . . . . . . . . . . . . . . . . . . . . . . . . 42
12
Soldering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
12.1
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . 45
12.2
Through-hole mount packages . . . . . . . . . . . 45
12.2.1
Soldering by dipping or by solder wave . . . . . 45
12.2.2
Manual soldering . . . . . . . . . . . . . . . . . . . . . . 45
12.3
Surface mount packages . . . . . . . . . . . . . . . . 45
12.3.1
Reflow soldering. . . . . . . . . . . . . . . . . . . . . . . 45
12.3.2
Wave soldering. . . . . . . . . . . . . . . . . . . . . . . . 46
12.3.3
Manual soldering . . . . . . . . . . . . . . . . . . . . . . 46
12.4
Package related soldering information . . . . . . 47
13
Revision history . . . . . . . . . . . . . . . . . . . . . . . 48
14
Data sheet status. . . . . . . . . . . . . . . . . . . . . . . 49
15
Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
16
Disclaimers . . . . . . . . . . . . . . . . . . . . . . . . . . . 49