ChipFind - документация

Электронный компонент: GH6C605B3B

Скачать:  PDF   ZIP
70
GH6C605B3A/GH6C605B3B/GH6C605B5A/GH6C605B5B
Hologram Lasers
Notice
In the absence of confirmation by device specification sheets,SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs,data books,etc.Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet
Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/
s
Absolute Maximum Ratings
(T
C
=25C)
1
Output power from hologram laser
2
Case temperature
3
At the position of 1.6mm or more from the lead base
(Within 5s)
Parameter
Symbol
Rating
Unit
1
Optical power output
P
H
4.3
mW
Reverse voltage
Laser
V
R
2
V
2
Operating temperature
T
opr
-10 to +70
C
2
Storage temperature
T
stg
-40 to +85
C
3
Soldering temperature
T
sold
260
C
Monitor photodiode
30
OPIC supply voltage
V
CC
6
V
V
GH6C605B3A/GH6C605B3B
GH6C605B5A/GH6C605B5B
s
Outline Dimensions
Resin Stem Hologram Laser for CD-
ROM Drive(Equivalent to
40 Speed)
(Unit : mm)
s
Features
(1) With built-in high speed response OPIC
(MIN. 40MHz)
(2) For CD-ROM drives (equivalent to
40 speed)
(3) Easy mounting due to insert frame structure compared to
conventional pin structure
(4) Thin and compact package which enables to design thin
and compact pick-up
GH6C605B3A/B
: 4.8mm thickness
GH6C605B5A/B
: 3.0mm thickness
(5) With built-in beam splitter and diffraction grating
OPIC : (Optical IC) is a trademark of the SHARP
Corporation. An OPIC consists of a light-
detecting element and signal-processing circuit
integrated onto a single chip.
s
Model No.
(1)
GH6C605B3A/GH6C605B5A
....Dual power supply
(2)
GH6C605B3B/GH6C605B5B
....Single power supply
s
Applications
(1) DVD-ROM drives
(2) CD-ROM drives for notebook PC
8.2
+
0
0.05
6.1 to 6.3
6.6
0.2
3.2
0.15
4.77
0.15
3.8
0.5
2.0
0.15
(0.8
0.2
)
3.3
0.2
1.2
0.2
12-0.4
0.1
2
0.2
(0.5
0.2
)
7.5
MAX.
Hologram device
Emission point
1.39
0.1 from reference plane
Reference plane
Z
X
Y
Z
X
Y
Y
Z
X
3.97
0.2
4.8
+
0
0.1
1.5
0.1
2.4
0.15
8.2
+
0
0.05
0.4
0.1
45
1
45
1
4.8
+
0 0.1
0.8
0.2
5=4
0.2
GH6C605B3A
GH6C605B3B
GH6C605B5A
GH6C605B5B
8.2
+
+
0
0.05
3
+
0
0.1
0.8
0.2
5=4
0.2
2.4
0.15
(1.5)
0.4
0.1
45
1
45
1
3
0 0.1
Hologram device
Emission point
1.39
0.1 from reference plane
Reference plane
Z
X
Y
Z
X
Y
Y
Z
X
8.2
+
0
0.05
6.1 to 6.3
6.6
0.2
3.2
0.15
4.77
0.15
3.8
0.5
2.0
0.15
(0.8
0.2
)
3.3
0.2
1.2
0.2
12-0.4
0.1
2
0.2
(0.5
0.2
)
7.5
MAX.
D3
Vcc
LD
GND
V
A
V
B
V
C
V
E
V
F
1/2Vcc
D4 D1
D2
D5
NC
NC
Monitor PD
e
!1
o
y
u
r
t
i
!0
!2
q
w
Monitor PD
(GH6C605B5A)(GH6C605B3A)
(GH6C605B5B)(GH6C605B3B)
w
qwerty
!2!1!0oiu
Y
Z
X
Terminal connection
Pin configuration
GH6C605B3A
GH6C605B3B
qwerty
!2!1!0oiu
Y
X
Z
GH6C605B5A
GH6C605B5B
71
GH6C605B3A/GH6C605B3B/GH6C605B5A/GH6C605B5B
Hologram Lasers
s
Electro-optical Characteristics
(V
CC
=5V, T
C
=25C)
1
Distance between FES=0 and jitter minimum point
At the condition of FES sensitivity = 20%/1m
2
(ab) / (a+b)
3
4
Amplitude of V
A
+V
B
+2V
C
(focal servo ON, radial servo ON)
5
V
A
V
B
(Focal vibration)
6
V
E
V
F
(focal servo ON, radial servo OFF)
ab
2(a+b)
a (+amplitude of RES)
b (amplitude of RES)
GND
a (+amplitude of FES)
b (amplitude of FES)
NA=0.50
f =4.5mm
NA=0.11
f =20.6mm
Disc
(SONY : YEDS-18)
Laser driver
APC circuit
Actuator
Collimated lens
Hologram laser
Measuring System of Hologram Laser
Parameter
Symbol
MAX.
Unit
1
Focal offset
DEF
+0.7
m
0.47
V
Differential efficiency
d
0.55
mW/mA
Conditions
MIN.
TYP.
V
RF
=0.55V
-0.7
-
0.23
0.35
2.0mW
I(3.0mW)-I(1.0mW)
0.17
0.27
2
Focal error symmetry
B
FES
V
RF
=0.55V
-25
-
+25
%
3
Radial error balance
B
RES
-25
-
+25
%
P
H
=3.0mW
4
RF output amplitude
V
RF
P
H
=3.0mW
0.42
1.00
-
V
0.08
0.12
0.16
V
Threshold current
I
th
-
-
25
39
mA
Operating current
I
op
P
H
=3.0mW
-
36
50
mA
Operating voltage
V
op
P
H
=3.0mW
-
1.75
2.2
V
Wavelength
p
P
H
=3.0mW
770
780
795
nm
0.05
0.22
0.60
mA
Output current
I
m
P
H
=3.0mW, V
R
=15V
0.06
0.32
0.60
mA
5
FES output amplitude
6
RES output amplitude
GH6C605B3A/GH6C605B5A
GH6C605B3B/GH6C605B5B
V
FES
V
RF
=0.55V
V
RES
V
RF
=0.55V
72
GH6C605B3A/GH6C605B3B/GH6C605B5A/GH6C605B5B
Hologram Lasers
s
Electrical Characteristics of Monitor Photodiode (Design Standard)
(GH6C605B3A/GH6C605B5A)
(T
C
=25C)
s
Electro-optical Characteristics of Laser Diode (Design Standard)
(T
C
=25C)
Parameter
Symbol
MAX.
Unit
Emission
characteristics
1
Symmetry
S
//
+25
%
+15
Misalignment position
x
+80
m
z
+80
m
Interference pattern intensity
0.99
-
Conditions
MIN.
TYP.
Parallel
-25
-
Perpendicular
-15
-
%
-80
-
-80
-
Po=3mW
-
-
S
y
-80
-
+80
m
Po=3mW, Into NA=0.11
-
Parameter
Symbol
MAX.
Unit
2
Sensitivity
S
-
mA/mW
150
Terminal capacitance
C
t
-
pF
Conditions
MIN.
TYP.
-
0.11
Dark current
-
-
nA
-
4.2
I
D
V
R
=15V
s
Electro-optical Characteristics of OPIC for Signal Detection (Design Standard)
(T
C
=25C)
Parameter
Symbol
Unit
3
Segment
Supply voltage
V
CC
V
Response frequency
f
CF
MHz
V
A
, V
B
, V
C
Conditions
MIN.
TYP.
4.5
5
40
55
1
Measuring method of radiation symmetry
3
Applicable divisions correspond to output terminals
4
Difference from Vcc/2
5
Output amplitude=0dB (input signal 100kHz) BW=10kHz
Segment No.
Output
D 1 ...............................................V
E
D 2 ...............................................V
A
D 3 ...............................................V
B
D 4 ...............................................V
C
D 5 ...............................................V
F
D1
D2
D3
D5
D4
MAX.
5.5
Supply current
I
CC
V
CC
=5V
6
9
12
mA
-15
0
+15
mV
V
E
, V
F
-15
0
+15
mV
V
E
-V
F
5
V
CC
=5V, -3dB
R
L
=10k
, CL=10pF
-
5
7
-
MHz
V
E
, V
F
Parameter
Definition
S//
S
(P
B
+ P
C
) - (P
A
+ P
D
)
P
A
+ P
B
+ P
C
+ P
D
(P
A
+ P
B
) - (P
C
+ P
D
)
P
A
+ P
B
+ P
C
+ P
D
P
X
: Output of light detector X
Reference plane
to 33mm (NA=0.11)
6.3
7.4mm
4-division photodetector
(10mm)
C
B
D
A
Laser diode
Y
Z
X
Y
Z
X
f
CR
4
Output off-set voltage
V
OD
V
CC
=5V
No light
-25
0
+25
mV
V
A
, V
B
, V
C
Off-set voltage difference
V
OD
-25
0
+25
mV
V
A
-V
B
(GH6C605B3B/GH6C605B5B)
(T
C
=25C)
Parameter
Symbol
MAX.
Unit
2
Sensitivity
S
-
mA/mW
150
Terminal capacitance
C
t
-
pF
Conditions
MIN.
TYP.
-
0.07
Dark current
-
-
nA
-
7.7
I
D
V
R
=15V
2
For hologram output power
115
Application Circuits
NOTICE
qThe circuit application examples in this publication are provided to explain representative applications of
SHARP devices and are not intended to guarantee any circuit design or license any intellectual property
rights. SHARP takes no responsibility for any problems related to any intellectual property right of a
third party resulting from the use of SHARP's devices.
qContact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
SHARP reserves the right to make changes in the specifications, characteristics, data, materials,
structure, and other contents described herein at any time without notice in order to improve design or
reliability. Manufacturing locations are also subject to change without notice.
qObserve the following points when using any devices in this publication. SHARP takes no responsibility
for damage caused by improper use of the devices which does not meet the conditions and absolute
maximum ratings to be used specified in the relevant specification sheet nor meet the following
conditions:
(i) The devices in this publication are designed for use in general electronic equipment designs such as:
--- Personal computers
--- Office automation equipment
--- Telecommunication equipment [terminal]
--- Test and measurement equipment
--- Industrial control
--- Audio visual equipment
--- Consumer electronics
(ii)Measures such as fail-safe function and redundant design should be taken to ensure reliability and
safety when SHARP devices are used for or in connection with equipment that requires higher
reliability such as:
--- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.)
--- Traffic signals
--- Gas leakage sensor breakers
--- Alarm equipment
--- Various safety devices, etc.
(iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely
high level of reliability and safety such as:
--- Space applications
--- Telecommunication equipment [trunk lines]
--- Nuclear power control equipment
--- Medical and other life support equipment (e.g., scuba).
qContact a SHARP representative in advance when intending to use SHARP devices for any "specific"
applications other than those recommended by SHARP or when it is unclear which category mentioned
above controls the intended use.
qIf the SHARP devices listed in this publication fall within the scope of strategic products described in the
Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export
such SHARP devices.
qThis publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under
the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any
means, electronic or mechanical, for any purpose, in whole or in part, without the express written
permission of SHARP. Express written permission is also required before any use of this publication
may be made by a third party.
qContact and consult with a SHARP representative if there are any questions about the contents of this
publication.