FM RF POWER AMPLIFIER MODULE for UHF BAND
Output Power :60W (Min.)
Power Gain :30.7dB (Min.)
Total Efficiency:40% (Min.)

MAXIMUM RATINGS
(Tc = 25
,
Z
G
= Z
L
= 50
)
CHARACTERISTIC SYMBOL
TEST
CONDITION
RATING
UNIT
DC Supply Voltage
V
DD
V
GG
=0V, Pi =0mW
16.5
V
DC Supply Voltage
V
DD
V
GG
5V, Pi =50mW, Po60W 16.5
V
DC Supply Voltage
V
GG
V
DD
12.5V, Pi =50mW
5.5
V
Total Current
I
T
V
DD
12.5V, Pi =50mW
15
A
Input Power
P
i
V
DD
12.5V, V
GG
5V 100
mW
Output Power
P
o
12.5V<
V
DD
16.5V, V
GG
5V, Pi =50mW
80
W
Operating Case Temperature Range
T
c (opr)
V
GG
5V -30~100
Storage Temperature Range
T
stg
-40~110
Caution: This maximum rating given in a sheet guarantees each item independently. When two items
or more of maximum rated items joins a device at once. It becomes the outside of a guarantee.
Please design in circuit to make it always operate within this reguration also on the worst condition.
PACKAGE OUTLINE






































RF Input V
GG
V
DD
RF Outout GROUND(FRANGE)
JEDEC --
JEITA --
TOSHIBA 5-53P
Weight: 35g
Unit in mm
S-AU82L
2 2004-01-06
ELECTRICAL CHARACTERISTICS
(Tc = 25
,
Z
G
= 50
)
CHARACTERISTIC SYMBOL
TEST
CONDITION MIN.
TYP.
MAX.
UNIT
Frequency Range
f
range
--
400 -- 470 MHz
Total Current ( DC operation )
I
T
V
DD
= 12.5V, V
GG
= 5V, Pi = 0mW
Z
L
= 50
-- -- 15 A
Output Power
P
o
60
--
--
W
Power Gain
G
p
30.7
--
--
dB
Total Efficiency
T
40
--
--
%
Input
VSWR
VSWRin
-- -- 3.0 --
Second Harmonic
2nd HRM
V
DD
= 12.5V
V
GG
= 5V
Pi = 50mW
Z
L
= 50
-- -- -30 dB
Third Harmonic
3rd HRM
--
--
-30
dB
Load Mismatch
--
V
DD
= 10.5 to 16.5V, V
GG
= 0 to 5V
Pi = 50mW
P
o
= 60W (V
GG
= adjust,@ Z
L
= 50)
VSWR LOAD 20: 1 ALL PHASE (@2s)
No Degradation
--
Stability --
V
DD
= 10.5 to 16.5V, V
GG
= 0 to 5V
Pi = 50mW
P
o
60W (V
GG
= adjust,@ Z
L
= 50)
VSWR LOAD 3: 1 ALL PHASE
All spurious output
than 60dB below
desired signal
--

Caution

This product has intersetting cap. Please pay attention for exceeding stress and foreign matter in your application.
And not to take away the cap.

Do not break, cut, crush or dissolve chemically. Dispose of this product properly according to law.
Do not intermingle with normal industrial or domestic waste.

This product is electrostatic sensitivity, please handle with caution.

This product is flowed high current for a VDD terminal at both RF ON and RF OFF. And it has large calorific value
for high output poer. So please use it within the limit of the maximum rating.
The view of the maximum rating of our company,
"The absolute maximum ratings are rated values which must not be exceeded during operatin,
even for an instant. And it guarantees each item independently. When two items or more of
maximum rated items joins a device at once. It becomes the outside of a guarantee. "


















S-AU82L
3 2004-01-06
SCHEMATIC























TEST FIXTURE





























V
GG
V
DD
Po
Z
L
=50
GROUND
(FRANGE)
Pi
Z
G
=50
Pi
Po
V
GG
V
DD
C1
C1
C2
C2
L
L
C1:15000pF
C2:10F
L:0.8 ENAMEL WIRE8T5ID
S-AU82L
4 2004-01-06
The information contained herein is subject to change without notice.
The information contained herein is presented only as a guide for the applications of our products. No
responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which
may result from its use. No license is granted by implication or otherwise under any patent or patent rights of
TOSHIBA or others.
TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor
devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical
stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of
safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of
such TOSHIBA products could cause loss of human life, bodily injury or damage to property.
In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as
set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and
conditions set forth in the "Handling Guide for Semiconductor Devices," or "TOSHIBA Semiconductor Reliability
Handbook" etc..
The TOSHIBA products listed in this document are intended for usage in general electronics applications
(computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances,
etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires
extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or
bodily injury ("Unintended Usage"). Unintended Usage include atomic energy control instruments, airplane or
spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments,
medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this
document shall be made at the customer's own risk.
TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced
and sold, under any law and regulations.
030619EAA
RESTRICTIONS ON PRODUCT USE