PPS40-1/2/3 SWITCHING MODE 40W OPEN FRAME POWER SUPPLIES
KEY FEATURES
*Universal input
* Built-in EMI filter
*Optional
12VDC/
24VDC/
48VDC input
APPLICATIONS
*Telecommunications
*Computer peripherals/ Lan & Hub
*Test & industrial equipments
*Medical instruments
*Business machines
ELECTRICAL SPECIFICATIONS
INPUT
*Input range-----------90~264 VAC, universal
*Frequency------------47~63Hz
*Inrush current--------25A typical, Cold start
@25,115VAC
*Efficiency------------65% ~80% typical at full load
*EMI filter------------
FCC Class B conducted, CISPR 22
Class B conducted, EN55022 class B
Conducted
*Line regulation----- +/- 0.5% typical
OUTPUT
*Maximum power----40W with 15 CFM forced air
(Refer next page)
*Hold-up time --------10ms typical at full load and 115 VAC
nominal line
*Overload protection-Short circuit protection
*Overvoltage
protection ------------Main output 20% to 40% above
nominal output
*Ripple/Noise -------- +/- 1% Max. @full load
(Optional +/-0.5% per inquiry)
40W
30W
20W
10W
0W
20W
15W
Power Derating Curve
15 CFM Forced Air Cooling
0
10 20 30
40
50
60
70
Ambient Temperature( C)
Natural
Convection
Cooling
Output
Power
(Watts)
EMI & EMC
*FCC part 15, Class B
*CISPR 22 / EN55022, Class B
*VCCI ,Class 2
*CE, EN 61000-3-2 (Class A) and 3; EN 61000-4-2,
-3,-4.-5,-6 and -11
SAFETY APPROVAL
*UL1950 / c UL
*Optional CSA 22.2, LEVEL 3 (COMPLY WITH)
*TUV EN60950
*Optional UL 2601 (EMI Class A)(COMPLY WITH)
ENVIRONMENTAL
*Operating temperature :
0 to
50
ambient; derate each output at 2.5% per
degree from 50to 70
*Humidity:
Operating; non-condensing, 5% to 95%
*Vibration :
10~55 Hz at 1G 3 minutes period, 30 minutes along
X, Y and Z axis
*Storage temperature:
-40 to 85
*Temperature coefficient:
+/- 0.05% per degree C
*MTBF demonstrated:
>100,000 hours at full load and 25ambient
conditions
TOTAL POWER INT'L
TPS40-1/2/3 40 WATT OPEN-FRAME SWITCHING POWER SUPPLY
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-1-
PPS40-1/2/3

SWITCHING MODE 40W OPEN FRAME POWER SUPPLIES
MODEL
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
MAXIMUM OUTPUT
CURRENT
PEAK OUTPUT
CURRENT(NOTE1)
MINIMUM OUTPUT
CURRENT
TOTAL
REGULATION(NOTE3)
RIPPLE & NOISE
%P-P(NOTE2)
PEAK OUTPUT
POWER(NOTE1)
SI NGLE OUTPUT MODEL SELECTION CHART
TPS40-10
+5V
10% Typical 8A 10A 0A
3%
1% 50W Typical
TPS40-11
+12V
10% Typical
3.3A
4.1A
0A
3%
1%
50W Typical
TPS40-12
+15V
10% Typical
2.6A
3.2A
0A
3%
1%
50W Typical
TPS40-13
+24V
10% Typical
1.6A
2A
0A
3%
1%
50W Typical
TPS40-14
+48V
10% Typical
0.8A
1A
0A
3%
1%
50W Typical
TPS40-15
+3.3V
10% Typical
9.6A
12A
0.96A
5%
1.5%
50W Typical
TPS40-16
+28V
10% Typical
1.4A
1.8A
0A
3%
1%
50W Typical
DUAL OUTPUT MODEL SELECTION CHART
+5 V
10% Typical
6A
9.6A
0.6A
5%
1%
TPS40-20
+12V
Fixed
1A
1.6A
0.1A
5%
1%
50W Typical
+5 V
10% Typical
6A
9.6A
0.6A
5%
1%
TPS40-21
+48V
Fixed
0.25A
0.4A
0.03A
5%
1%
50W Typical
+5 V
10% Typical
6A
9.6A
0.6A
5%
1%
TPS40-22
- 5V
Fixed
2A
3.2A
0.2A
10%
1%
50W Typical
+12V
10% Typical
1.6A
2.5A
0.16A
5%
1%
TPS40-23
- 12V
Fixed
1.6A
2.5A
0.16A
10%
1%
50W Typical
+15V
10% Typical
1.3A
2A
0.13A
5%
1%
TPS40-24
- 15V
Fixed
1.3A
2A
0.13A
10%
1%
50W Typical
+3.3V
10% Typical
10A
16A
1A
5%
1.5%
TPS40-25
+5V
Fixed
1.5A
2.4A
0.15A
5%
1%
50W Typical
TRIPLE OUTPUT MODEL SELECTION CHART
+ 5V
10% Typical
5A
8A
0.5A
5%
1%
+12V
Fixed
0.75A
1.2A
0.08A
5%
1%
TPS40-30
- 5 V
Fixed
1.2A
1.9A
0.12A
10%
1%
50W Typical
+ 5V
10% Typical
5A
8A
0.5A
5%
1%
+12V
Fixed
0.75A
1.2A
0.08A
5%
1%
TPS40-31
-12V
Fixed
0.5A
0.8A
0.05A
10%
1%
50W Typical
+ 5V
10% Typical
5A
8A
0.5A
5%
1%
+15V
Fixed
0.5A
0.8A
0.05A
5%
1%
TPS40-32
-15V
Fixed
0.5A
0.8A
0.05A
10%
1%
50W Typical
+5V
10% Typical
4A
6.4A
0.4A
5%
1%
+15V
Fixed
1A
1.6A
0.1A
5%
1%
TPS40-33
-5V
Fixed
1A
1.6A
0.1A
10%
1%
50W Typical
+5V
10% Typical
4A
6.4A
0.4A
5%
1%
+15V
Fixed
0.8A
1.2A
0.08A
5%
1%
TPS40-34
-12V
Fixed
0.7A
1.1A
0.07A
10%
1%
50W Typical
+ 5V
10% Typical
4A
6.4A
0.4A
5%
1%
+24V
Fixed
0.5A
0.8A
0.05A
5%
1%
TPS40-35
-12V
Fixed
0.7A
1.1A
0.07A
10%
1%
50W Typical
+ 5V
10% Typical
4A
6.4A
0.4A
5%
1%
+12V
Fixed
0.75A
1.2A
0.08A
5%
1%
TPS40-36
-12V
Fixed
1A
1.6A
0.1A
10%
1%
50W Typical
+5V
10% Typical
4A
6.4A
0.4A
5%
1%
+12V
Fixed
0.75A
1.2A
0.08A
5%
1%
TPS40-37
+24V
Fixed
0.5A
0.8A
0.05A
10%
1%
50W Typical
+5V
10% Typical
2.4A
3.8A
0.24A
5%
1%
+12V
Fixed
1.2A
1.9A
0.12A
5%
1%
TPS40-38
+48V
Fixed
0.3A
0.5A
0.03A
10%
1%
50W Typical
NOTES: 1) Peak loads for lasting <30 seconds with a maximum 10% duty cycle are acceptable. Please contact us if need special peak load.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth, input not less nominal line,0.1F and 47F Cap. on outputs.
3) Loading test conditions are set for all outputs at minimum, middle and maximum of loads. Special cross loading requirement is welcomed.
4) Detailed engineering specification of each model is available for inquiry.
5) Special output voltage/current inquiry is welcomed.
6) Specifications subject to change without notice.
7) 25% derated if 24 VDC input version;50% derated if 12 VDC input version;25% derated if additional cover.
TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395
Email: sales@total-power.com http://www.total-power.com
-2-