ChipFind - документация

Электронный компонент: VI-A11-CU

Скачать:  PDF   ZIP
12
1-800-735-6200
76
Note: For alternative product grades, change the "C" in the part number to "E", "I" or "M"
PARAMETER
MIN
TYP
MAX
POWER
REMARKS
Input Range/Power Limit
VI-A11-CU
21Vdc
24Vdc
32Vdc
200W
Delivered power is
VI-AWW-CU
18Vdc
24Vdc
36Vdc
200W
from any combination
VI-A33-CQ
42Vdc
48Vdc
60Vdc
400W
of DC-DC converters
VI-ANN-CQ
36Vdc
48Vdc
76Vdc
400W
VI-A66-CQ
200Vdc
300Vdc 400Vdc
400W
Isolation
1,500 V
RMS
Input /Output to Base
Size
2.28" x 2.4" x 0.5" (57,9 x 61,0 x 12,7)
Weight
3.0 Ounces (85 Grams)
EMI/ RFI (conducted
Meets Bellcore TR-TSY-000513, Issue 2, Rev. 1
emissions)
(24 and 48V Input);
British Telecom BTR 2511, Issue 2
(24 and 48V Input);
FCC Part 15, Class A, EN55022 Class B
Transient Protection
Meets Bellcore TA-TSY-001003, Issue 1, 9/89
British Telecom BTR 2511, IEC 61000-4-5 Level 2(VI-A66 only)
Reverse Polarity Protection No damage to unit
PRODUCT GRADE
PARAMETER E
C
I
M
Storage Temp.
20C to +105C
40C to +105C
55C to +105C
65C to +105C
Operating Temp.
10C to +100C
25C to +100C
40C to +100C
55C to +100C
(Baseplate)
Features
s Inputs: 24, 48 and 300Vdc
s High Surge Withstand:
Bellcore
British Telecom BTR 2511
IEC-60801-5
s EMI/RFI Specifications:
Bellcore TR-TSY-000513
British Telecom BTR 2511
FCC Level "A"
EN55022 Level "B"
s UL, CSA, TV, VDE, BABT
s 97% Efficiency
s Input Reverse Polarity Protection
s Logic Disable
s Expansion Output for Arrays
s Size: 2.28" x 2.4" x 0.5"
(57,9 x 61,0 x 12,7)
s CE Marked
Product Highlights
The Input Attenuator Module (VI-IAM) is
a component-level, DC input front end
filter designed to occupy minimum board
space while providing maximum protection
for today's sophisticated electrical
systems. The VI-IAM, in combination
with Vicor 24, 48 and 300Vdc input
modules, provides a highly efficient, high
density power system with outputs from
1 to 95Vdc and power expandable from
25 to 800W. Your system will benefit from
the small size, efficiency and inherent
reliability of Vicor's component-level
converters, while meeting the toughest
demands of Telecommunications and
Industrial power applications.
This combination provides
compliance with the transient
requirements of Bellcore, British
Telecom and IEC standards, and meets the
EMI/RFI specifications of Bellcore,
British Telecom and FCC Part 15, Subpart
B and EN55022.
Compatible Products
s VI-200 and VI-J00
(Inputs: 1, W, 3, N and 6)
s Mega Modules
(Inputs: 1, W, 3, N and 6)
VI-IAM
TM
Input Attenuator
Modules
Product Grade Specifications
VI-IAM Specifications
(typical at T
BP
= 25C, nominal line, 75% load, unless otherwise specified)
0.1 1 10ms 100 1000
100V
Normal Operating Area
I.S.W.
Full Load
100V
Standard
Wide Range
24V Inputs
0.1 1 10ms 100 1000
800V
Normal Operating Area
I.S.W.
Full Load
300V Input
S.D.
160V
0.1 1 10ms 100 1000
Normal Operating Area
I.S.W.
Full Load
48V Input
R.E.
276V
Normal Operating Area
I.S.W.
Full Load
0.1 1 10ms 100 1000
48V Wide Range Input
R.E.
S.D.
R.E.
R.E.
32V
21V
36V
18V
S.D.
76V
125V
60V
100V
42V
500V
400V
200V
36V
S.D.
S.D.
100V
500 ms
500 ms
Long Term Safe Operating Area Curves
(1% duty cycle max., Z
s
= .5
, for short duration transient capability refer to specifications)
12
1-800-735-6200
77
Mechanical Drawing
5
6
7
8
9
4
3
2
1
.080 Dia (2) places
Solder plate
over copper alloy
.040 (1,0) Dia (7) places
Solder plate
over copper alloy
.01
Aluminum Base
Product ID
this surface
Function
+In
In
+Out
Parallel
Gate Out
Out
Pin #
1
2
3
4
5
6
7
8
9
FULL R
+.030 (0,76)
-.000 (0)
.22 (5,6) Min.
.30 (7,6) Min.
1.75 (44,4) Max.
2.40 (61,0)
2.28 (57,9)
.12 (3,0)
.50 (12,7)
1.90 (48,3)
.65
(16,5)
.49
(12,4)
.15 (3,8)
.30 (7,6)
.015 (0,38)
.15 (3,8)
2.10
(53,4)
1.30 (33,0)
.40
(10,2)
.35 (8,9)
.015 (0,38)
1.40
(35,6)
1.00
(25,4)
.70
(17,8)
+In
In
Gate In
VI-IAM